119 resultados para Analyst recommendation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To determine how long it takes from the decision to achieve delivery by non-elective caesarean section (DDI), the influence on this interval, and the impact on neonatal condition at birth. Design Twelve months prospective data collection on all non-elective caesarean sections. Methods Prospective collection of data relating to all caesarean sections in 1996 in a major teaching hospital obstetric unit was conducted, without the knowledge of the other clinicians providing clinical care. Details of the indication for section, the day and time of the decision and the interval till delivery were recorded as well as the seniority of the surgeon, and condition of the baby at birth. Results The mean time from decision-to-delivery for 100 emergency intrapartum caesarean sections was 42.9 minutes for fetal distress and 71.1 minutes for 230 without fetal distress (P<0.0001). For 22 'crash' sections the mean time from decision-to-delivery was 27.4 minutes; for 13 urgent antepartum deliveries for fetal reasons it was 124.7 minutes and for 21 with maternal reasons it was 97.4 minutes. The seniority of the surgeon managing the patient did not appear to influence the interval, nor did the time of day or day of the week when the delivery occurred. Intrapartum sections were quicker the more advanced the labour, and general anaesthesia was associated with shorter intervals than regional anaesthesia for emergency caesarean section for fetal distress (P<0.001). Babies born within one hour of the decision tended to be more acidaemic than those born later, irrespective of the indication for delivery. Babies tended to be in better condition when a time from decision-to-delivery was not recorded than those for whom the information had been recorded. Conclusion Fewer than 40% intrapartum deliveries by caesarean section for fetal distress were achieved within 30 minutes of the decision, despite that being the unit standard. There was, however, no evidence to indicate that overall an interval up to 120 minutes was detrimental to the neonate unless the delivery was a 'crash' caesarean section. These data thus do not provide evidence to sustain the recommendation of a standard of 30 minutes for intrapartum delivery by caesarean section.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article reports on the first extensive survey of Approved Social Worker (ASW) activity under the Mental Health (Northern Ireland) Order 1986. The integrated health and social services organizational structure, the adverse effects on individual mental health of the legacy of thirty years of civil conflict and the move from hospital to community care are significant features which have influenced the delivery of mental health social work services locally. The practice and experience of ASWs was surveyed by postal questionnaire and user and carer experience of compulsory hospital admission was investigated by a series of focus groups. The study revealed that two&hyphen;thirds of ASWs had experience of acting as an applicant in compulsory hospital admission during the past two years. Nearly half (42 per cent) of these ASWs had reported experience of between one and five admissions and one&hyphen;tenth had completed over twenty admissions in the two&hyphen;year period. In only a small minority of cases did joint face&hyphen;to&hyphen;face assessment with the General Practitioner (doctor) take place; nearly half of ASWs reported difficulties in obtaining transport; and only one&hyphen;fifth of ASWs had experience of acting as a second approved social worker. Half of ASWs reported experience of guardianship, either as applicant or in making the recommendation. Both service users and carers reported a lack of understanding about the role of the ASW and complained about the lack of alternative resources that ASWs could use to prevent hospital admissions. These findings are discussed and a number of recommendations are proposed for improvements to approved social worker practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The definitive paper by Stuiver and Polach (1977) established the conventions for reporting of 14C data for chronological and geophysical studies based on the radioactive decay of 14C in the sample since the year of sample death or formation. Several ways of reporting 14C activity levels relative to a standard were also established, but no specific instructions were given for reporting nuclear weapons testing (post-bomb) 14C levels in samples. Because the use of post-bomb 14C is becoming more prevalent in forensics, biology, and geosciences, a convention needs to be adopted. We advocate the use of fraction modern with a new symbol F14C to prevent confusion with the previously used Fm, which may or may not have been fractionation corrected. We also discuss the calibration of post-bomb 14C samples and the available datasets and compilations, but do not give a recommendation for a particular dataset.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study finds evidence that attempts to reduce costs and error rates in the Inland Revenue through the use of e-commerce technology are flawed. While it is technically possible to write software that will record tax data, and then transmit it to the Inland Revenue, there is little demand for this service. The key finding is that the tax system is so complex that many people are unable to complete their own tax returns. This complexity cannot be overcome by well-designed software. The recommendation is to encourage the use of agents to assist taxpayers or simplify the tax system. The Inland Revenue is interested in saving administrative costs and errors by encouraging electronic submission of tax returns. To achieve these objectives, given the raw data it would seem clear that the focus should be on facilitating the work of agents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The production of an antibody to detect toltrazuril or its metabolite ponazuril is complicated due to structural constraints of conjugating these coccidiostats to a carrier protein. Therefore a search was carried out for a compound that shared a common substructure to use as an antigen mimic. The chosen compound, trifluoraminoether, was conjugated to two carrier proteins (HSA and BTG) and used in the immunisation of six rabbits. Two immunogen doses (1 mg and 0.1 mg) were also used. All six rabbits produced an immunological response to the hapten regardless of the carrier protein or immunogen dose used. The most sensitive polyclonal antibody produced, designated R609, was subsequently characterised. This antiserum exhibited an IC50 of 18 ng ml-1 using a competitive ELISA format. Cross reactivity studies show that this serum is specific for toltrazuril and its metabolites (toltrazuril sulfoxide and toltrazuril sulfone) but does not cross-react with other coccidiostats such as halofuginone, nitroimidazoles or nicarbazin. This is the first reported production of an antibody capable of specifically binding toltrazuril and ponazuril.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new calibration curve for the conversion of radiocarbon ages to calibrated (cal) ages has been constructed and internationally ratified to replace IntCal98, which extended from 0-24 cal kyr BP (Before Present, 0 cal BP = AD 1950). The new calibration data set for terrestrial samples extends from 0-26 cal kyr BP, but with much higher resolution beyond 11.4 cal kyr BP than IntCal98. Dendrochronologically-dated tree-ring samples cover the period from 0-12.4 cal kyr BP. Beyond the end of the tree rings, data from marine records (corals and foraminifera) are converted to the atmospheric equivalent with a site-specific marine reservoir correction to provide terrestrial calibration from 12.4-26.0 cal kyr BP. A substantial enhancement relative to IntCal98 is the introduction of a coherent statistical approach based on a random walk model, which takes into account the uncertainty in both the calendar age and the (super 14) C age to calculate the underlying calibration curve (Buck and Blackwell, this issue). The tree-ring data sets, sources of uncertainty, and regional offsets are discussed here. The marine data sets and calibration curve for marine samples from the surface mixed layer (Marine04) are discussed in brief, but details are presented in Hughen et al. (this issue a). We do not make a recommendation for calibration beyond 26 cal kyr BP at this time; however, potential calibration data sets are compared in another paper (van der Plicht et al., this issue).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sedatives and tranquillisers are frequently used to reduce stress during the transportation of food producing animals. The most widely used classes of sedatives include the butyrophenone azaperone, the phenothiazines acepromazine, propionylpromazine, chlorpromazine and the beta-blocker, carazolol. For regulatory control purposes, tolerances for azaperone and carazolol have been set by the European Union as 100 and 25 mug kg(-1), respectively. Furthermore, the use of the phenothiazines is prohibited and therefore has a zero tolerance. A method for the detection of residues of five tranquillisers and one beta-blocker using a single ELISA plate has been developed. Kidney samples (2.5 g) were extracted with dichloromethane and applied to a competitive enzyme immunoassay using three polyclonal antibodies raised in rabbits against azaperol, propionylpromazine and carazolol conjugates. In sample matrix, the azaperol antibody cross-reacted 28.0% with azaperone and the propionylpromazine antibody cross-reacted 24.9% with acepromazine and 11.7% with chlorpromazine. In the ELISA, the detection capabilities of the six sedatives, azaperol, azaperone, carazolol, acepromazine, chlorpromazine, and propionylpromazine are 5, 15, 5, 5, 20 and 5 mug kg(-1), respectively. The proposed method is a sensitive and rapid multi-residue technique that offers a cost effective alternative to current published procedures, without any concession on the ability to detect sedative misuse.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

When attempting to quantify the volatile components of a food isolated by dynamic headspace trapping onto an adsorbent, the analyst has to select the most appropriate compounds to use as standards and at which stage of the analysis to add them. Factors to be borne in mind include the volatility of the standard, the response of the GC detector, and whether to add the standard to the sample or to the adsorbent trap. This chapter considers the issues and describes the application of one chosen method to the quantitation of the volatile components of baked potato.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

X-Ray Photoelectron Spectroscopy (XPS) was used to quantify the amount of bromide ions present in two samples of [C(4)mpyrr]Br dissolved in the room temperature ionic liquid (RTIL) [C(4)mpyrr][N(Tf)(2)]. One sample was of a known concentration (0.436 Br atom%); the other was a saturated solution. The results obtained from quantitative XPS analysis indicated that the saturated sample had a concentration, or solubility, of 0.90 Br atom% (746 mM) at 298 K, which was then independently confirmed by potential-step chronoamperometry of the same solution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dipicolinic acid (DPA) is an excellent marker compound for bacterial spores, including those of Bacillus anthracis ( anthrax). Surface-enhanced Raman spectroscopy (SERS) potentially has the sensitivity and discrimination needed for trace DPA analysis, but mixing DPA solutions with citrate-reduced silver colloid only yielded measurable SERS spectra at much higher (> 80 ppm) concentrations than would be desirable for anthrax detection. Aggregation of the colloid with halide salts eliminated even these small DPA bands but aggregation with Na2SO4(aq) resulted in a remarkable increase in the DPA signals. With sulfate aggregation even 1 ppm solutions gave detectable signals with 10 s accumulation times, which is in the sensitivity range required. Addition of CNS- as an internal standard allowed quantitative DPA analysis, plotting the intensity of the strong DPA 1010 cm(-1) band (normalised to the ca. 2120 cm(-1) CNS- band) against DPA concentration gave a linear calibration (R-2 = 0.986) over the range 0 - 50 ppm DPA. The inclusion of thiocyanate also allows false negatives due to accidental deactivation of the enhancing medium to be detected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapid, quantitative SERS analysis of nicotine at ppm/ppb levels has been carried out using stable and inexpensive polymer-encapsulated Ag nanoparticles (gel-colls). The strongest nicotine band (1030 cm(-1)) was measured against d(5)-pyridine internal standard (974 cm(-1)) which was introduced during preparation of the stock gel-colls. Calibration plots of I-nic/I-pyr against the concentration of nicotine were non-linear but plotting I-nic/I-pyr against [nicotine](x) (x = 0.6-0.75, depending on the exact experimental conditions) gave linear calibrations over the range (0.1-10 ppm) with R-2 typically ca. 0.998. The RMS prediction error was found to be 0.10 ppm when the gel-colls were used for quantitative determination of unknown nicotine samples in 1-5 ppm level. The main advantages of the method are that the gel-colls constitute a highly stable and reproducible SERS medium that allows high throughput (50 sample h(-1)) measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large numbers of identical and stable SE(R)RS [surface-enhanced (resonance) Raman]-active media, which are convenient to handle and manipulate but sufficiently inexpensive that they can be used once and then discarded, have been prepared by isolating nanoparticles from Ag and Au sols in hydrophilic polymer gels. The preparation simply involves mixing a suitable polymer with the sol to give a viscous suspension that can be coated onto a substrate and dried to form a hard translucent film. The films remain inactive until they are treated with aqueous analyte solution, which causes the film to swell and brings the analyte into contact with the active metal particles. The swollen films give strong SERS spectra which are effectively identical to those obtained from simple sols. The advantage of this method is that the dried polymers can be stored indefinitely before use and that they give a high degree of spectral reproducibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monolithic catalysts are widely used as structured catalysts, especially in the abatement of pollutants. Probing what happens inside these monoliths during operation is, therefore, vital for modelling and prediction of the catalyst behavior. SpaciMS is a spatially resolved capillary-inlet mass spectroscopy system allowing for the generation of spatially resolved maps of the reactions within monoliths. In this study SpaciMS results combined with 3D CFD modelling demonstrate that SpaciMS is a highly sensitive and minimally invasive technique that can provide reaction maps as well as catalytic temporal behavior. Herein we illustrate this by examining kinetic oscillations during a CO oxidation reaction over a Pt/Rh on alumina catalyst supported on a cordierite monolith. These oscillations were only observed within the monolith by SpaciMS between 30 and 90% CO conversion. Equivalent experiments performed in a plug-flow reactor using this catalyst in a crushed form over a similar range of reaction conditions did not display any oscillations demonstrating the importance of intra monolith analysis. This work demonstrates that the SpaciMS offers an accurate and comprehensive picture of structured catalysts under operation.