21 resultados para Accelerated Solvent Extraction (Dionex ASE)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Heterocyclic aromatic amines (HCA) are carcinogenic mutagens formed during cooking of proteinaceous foods, particularly meat. To assist in the ongoing search for biomarkers of HCA exposure in blood, a method is described for the extraction from human plasma of the most abundant HCAs: 2-Amino-1-methyl-6-phenylimidazo(4,5-b)pyridine (PhIP), 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx) and 2-amino-3,4,8-trimethylimidazo[4,5-f]quinoxaline (4,8-DiMeIQx) (and its isomer 7,8-DiMeIQx), using Hollow Fibre Membrane Liquid-Phase Microextraction. This technique employs 2.5 cm lengths of porous polypropylene fibres impregnated with organic solvent to facilitate simultaneous extraction from an alkaline aqueous sample into a low volume acidic acceptor phase. This low cost protocol is extensively optimised for fibre length, extraction time, sample pH and volume. Detection is by UPLC-MS/MS using positive mode electrospray ionisation with a 3.4 min runtime, with optimum peak shape, sensitivity and baseline separation being achieved at pH 9.5. To our knowledge this is the first description of HCA chromatography under alkaline conditions. Application of fixed ion ratio tolerances for confirmation of analyte identity is discussed. Assay precision is between 4.5 and 8.8% while lower limits of detection between 2 and 5 pg/mL are below the concentrations postulated for acid-labile HCA-protein adducts in blood.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A series of imprinted polymers targeting nucleoside metabolites, prepared using a template analogue approach, are presented. These were prepared following selection of the optimum functional monomer by solution association studies using 1H-NMR titrations whereby methacrylic acid was shown to be the strongest receptor with and affinity constant of 621 ± 51 L mol-1 vs. 110 ± 16 L mol-1 for acrylamide. The best performing polymers were prepared using methanol as porogenic co-solvent and although average binding site affinities were marginally reduced, 2.3×104 L mol-1 vs. 2.7×104 L mol-1 measured for a polymer prepared in acetonitrile, these polymers contained the highest number of binding sites, 5.27 μmol g-1¬¬ vs. 1.64 μmol g-1, while they also exhibited enhanced selectivity for methylated guanosine derivatives. When applied as sorbents in the extraction of nucleoside derivative cancer biomarkers from synthetic urine samples, significant sample clean-up and recoveries of up to 90% for 7-methylguanosine were achieved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The invention relates to a process for dissolving metals (e.g., Al, Cu, Fe, Cr, Sb, Ti, and W) in perhalide contg. ionic liqs. having the formula (I), and to the extn. of metals from mineral ores; the remediation of materials contaminated with heavy, toxic, or radioactive metals; and to the removal of heavy and toxic metals from hydrocarbon streams. In the formula (I), [X] comprises at least one perhalide anion selected from [I3]-, [BrI2]-, [Br2I]-, [ClI2]-, [ClBr2]-, [BrCl2]-, or [ICl2]-, [ClI3]-. The (Cat+) is a cationic species selected from: ammonium, azaannulenium, azathiazolium, benzimidazolium, benzofuranium, benzotriazolium, borolium, cinnolinium, diazabicyclodecenium, diazabicyclononenium, diazabicyclo- undecenium, dithiazolium, furanium, guanidinium, imidazolium, indazolium, indolinium, indolium, morpholinium, oxaborolium, oxaphospholium, oxazinium, oxazolium, iso-oxazolium, oxathiazolium, pentazolium, phospholium, phosphonium, phthalazinium, piperazinium, piperidinium, pyranium, pyrazinium, pyrazolium, pyridazinium, pyridinium, pyrimidinium, pyrrolidinium, pyrrolium, quinazolinium, quinolinium, isoquinolinium, quinoxalinium, selenozolium, sulfonium, tetrazolium, iso-thiadiazolium, thiazinium, thiazolium, thiophenium, thiuronium, triazadecenium, triazinium, triazolium, iso-triazolium, and uronium. [on SciFinder(R)]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of neuropeptides in complex biological tissue samples requires efficient and appropriate extraction methods so that immunoreactivity is retained for subsequent radioimmunoassay detection. Since neuropeptides differ in their molecular mass, charge and hydrophobicity, no single method will suffice for the optimal extraction of various neuropeptides. In this study, dental pulp tissue was obtained from 30 human non-carious teeth. Of the three different neuropeptide extraction methods employed, boiling in acetic acid in the presence of protease inhibitors yielded the highest levels of neuropeptide Y (NPY) and vasoactive intestinal polypeptide (VIP). High pressure liquid chromatography (HPLC) analysis of dental pulp tissue verified the authenticity of the neuropeptides extracted. © 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes the development of the first ion pair solid phase extraction technique (IPSPE), which has been applied to the extraction of metformin from plasma samples. In addition an ion pair chromatographic method was developed for the specific HPLC determination of metformin. Several extraction and HPLC methods have been described previously for metformin, however, most of them did not solve the problems associated with the high polarity of this drug. Drug recovery in the developed method was found to be more than 98%. The limit of detection and limit of quantification was 3 and 5 ng/ml, respectively. The intraday and interday precision (measured by coefficient of variation, CV%) was always less than 9%. The accuracy (measured by relative error, R.E.%) was always less than 6.9%. Stability analysis showed that metformin is stable for at least 3 months when stored at -70degreesC. The method has been applied to 150 patient samples as part of a medication adherence study. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly-L-lactide (PLLA) is one of the most significant members of a group of polymers regarded as bioresorbable. The degradation of PLLA proceeds through hydrolysis of the ester linkages in the polymer's backbone; however, the time for the complete resorption of orthopaedic devices manufactured from PLLA is known to be in excess of five years in a normal physiological environment. To evaluate the degradation of PLLA in an accelerated time period, PLLA pellets were processed by compression moulding into tensile test specimens, prior to being sterilized by ethylene oxide gas (EtO) and degraded in a phosphate-buffered solution (PBS) at both 50°C and 70°C. On retrieval, at predetermined time intervals, procedures were used to evaluate the material's molecular weight, crystallinity, mechanical strength, and thermal properties. The results from this study suggest that at both 50°C and 70°C, degradation proceeds by a very similar mechanism to that observed at 37°C in vitro and in vivo. The degradation models developed also confirmed the dependence of mass loss, melting temperature, and glass transition temperature (Tg) on the polymer's molecular weight throughout degradation. Although increased temperature appears to be a suitable method for accelerating the degradation of PLLA, relative to its physiological degradation rate, concerns still remain over the validity of testing above the polymer's Tg and the significance of autocatalysis at increased temperatures.