56 resultados para 23-225
Optical source model for the 23.2-23.6 nm radiation from the multielement germanium soft X-ray laser
Resumo:
Distributions of source intensity in two dimensions (designated the source model), averaged over a single laser pulse, based on experimental measurements of spatial coherence, are considered for radiation from the unresolved 23.2/23.6 nm spectral lines from the germanium collisional X-ray laser. The model derives from measurements of the visibility of Young slit interference fringes determined by a method based on the Wiener-Khinchin theorem. Output from amplifiers comprising three and four target elements have similar coherence properties in directions within the horizontal plane corresponding to strong plasma refraction effects and fitting the coherence data shows source dimensions (FWHM) are similar to 26 mu m (horizontal), significantly smaller than expected by direct imaging, and similar to 125 mu m (vertical: equivalent to the height of the driver excitation). (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
The spatial coherence of a nanosecond pulsed germanium collisionally excited x-ray laser is measured experimentally for three target configurations. The diagnostic is based on Young's slit interference fringes with a dispersing element to resolve the 23.2- and 23.6-nm spectral lines. Target configurations include a double-slab target, known as the injector, and geometries in which the injector image is image relayed to seed either an additional single-slab target or a second double-slab target. A special feature of this study is the observation of the change in the apparent source size with angle of refraction across the diverging laser beam. Source sizes derived with a Gaussian source model decrease from 44 mu m for the injector target by a variable factor of as much as 2, according to target configuration, for beams leaving the additional amplifiers after strong refraction in the plasma. (C) 1998 Optical Society of America [S0740-3224(98)00810-8].
Resumo:
The time dependence of the spatial coherence of the combined spectral lines at 23.2 and 23.6 nm from the Ge XXIII collisionally pumped soft-x-ray laser with a double-slab target is examined within a single nanosecond pulse by use of Young's interference fringes and a streak camera. High source intensity is linked with low spatial coherence and vice verse. Calculations of the source intensity, size, and position have also been made; these calculations refer to a single-slab source. Comparison between the observed and calculated intensities, and of the source sizes both calculated and derived from the Young's fringes by interpretation with a Gaussian model of source emission, show good agreement in general trends. (C) 1998 Optical Society of America [S0740-3224(98)01905-5].
Resumo:
We have tested soft X-ray lasing in neon-like germanium with cylindrical targets where wave guiding and plasma confinement may affect lasing. An intense soft X-ray laser beam of 0.05 MW peak power and a narrow beam divergence (8 mrad) was produced at 23.6 nm with a 4 cm long straight cylindrical target of 0.72 mm inner diameter. Bending the cylindrical target to form a toroidal shape increased the lasing intensity by a factor of 3 accompanied with reduction of the beam divergence from 8 to 6 mrad.
Resumo:
Amplification of spontaneous emission at 23.6 nm has been studied in a Ge plasma heated by a 1 TW, 1.06 mum wavelength, laser pulse. The exponent of the axial gain reached 21 in a geometry with Fresnel number less-than-or-equal-to 1. Two plasma columns were produced by irradiation of slab targets up to a combined length of 3.6 cm. A narrow band XUV mirror allowed double pass amplification. Saturation of ASE output at 23.6 nm was observed as a change from exponential to linear growth of the output with plasma length. Further evidence of the effect was provided by a decline in the ratio of the output at 23.6 nm to that at 23.2 nm from approximately 1.6: 1 to approximately 0.5: 1, the latter being the theoretically predicted value for saturated operation. The onset of saturation at gL almost-equal-to 15 is consistent with model calculations. The beam divergence was about 8x diffraction limited with a brightness estimated at almost-equal-to 10(14) W/cm2/ster.
Resumo:
Amplification of spontaneous emission (ASE) at 23.6 nm has been studied in a Ge plasma heated by a 1 TW infrared laser pulse. The exponent of the axial gain reached 21 in a geometry with Fresnel number less-than-or-equal-to 1. Two plasma columns of combined length up to 36 mm were used with an extreme ultraviolet mirror giving double-pass amplification. Saturation of the ASE output was observed. The beam divergence was about 8 x diffraction limited with a brightness estimated at 10(14) W cm-2 sr-1. The feedback from the mirror was significantly reduced probably by radiation damage from the plasma.
Resumo:
Objectives: To investigate seasonal variation in month of diagnosis in children with type 1 diabetes registered in EURODIAB centres during 1989-2008.
Methods: 23 population-based registers recorded date of diagnosis in new cases of clinically diagnosed type 1 diabetes in children aged under 15 years. Completeness of ascertainment was assessed through capture-recapture methodology and was high in most centres. A general test for seasonal variation (11df) and Edward's test for sinusoidal (sine wave) variation (2df) were employed. Time series methods were also used to investigate if meteorological data were predictive of monthly counts after taking account of seasonality and long term trends.
Results: Significant seasonal variation was apparent in all but two small centres, with an excess of cases apparent in the winter quarter. Significant sinusoidal pattern was also evident in all but two small centres with peaks in December (14 centres), January (5 centres) or February (2 centres). Relative amplitude varied from ±11% to ±39% (median ±18%). There was no relationship across the centres between relative amplitude and incidence level. However there was evidence of significant deviation from the sinusoidal pattern in the majority of centres. Pooling results over centres, there was significant seasonal variation in each age-group at diagnosis, but with significantly less variation in those aged under 5 years. Boys showed marginally greater seasonal variation than girls. There were no differences in seasonal pattern between four sub-periods of the 20 year period. In most centres monthly counts of cases were not associated with deviations from normal monthly average temperature or sunshine hours; short term meteorological variations do not explain numbers of cases diagnosed.
Conclusions: Seasonality with a winter excess is apparent in all age-groups and both sexes, but girls and the under 5s show less marked variation. The seasonal pattern changed little in the 20 year period.
Resumo:
Triclabendazole is the only anthelmintic drug, which is active against immature, mature and adult stages of fluke. The objective of this work was to develop an analytical method to quantify and confirm the presence of triclabendazole residues around the MRL. In this work, a new analytical method was developed, which extended dynamic range to 1–100 and 5–1000 g kg-1 for milk and tissue, respectively. This was achieved using a mobile phase containing trifluoroacetic acid (pKa of 0.3), which resulted in the formation of the protonated pseudomolecular ions, [M+H]+, of triclabendazole metabolites. Insufficient
ionisation of common mobile phase additives due to low pKa values (<2) was identified as the cause of poor linearity. The new mobile phase conditions allowed the analysis of triclabendazole residues in liver, muscle and milk encompassing their EU maximum residue levels (MRL) (250, 225 and 10 g kg-1 respectively). Triclabendazole residues were extracted using a modified QuEChERS method and analysed by positive electrospray ionisation mass spectrometry with all analytes eluted by 2.23 min. The method was validated at the MRL according to Commission Decision (CD) 2002/657/EC criteria. The decision limit (CC) of the method was in the range of 250.8–287.2, 2554.9–290.8 and 10.9–12.1 g kg-1 for liver, muscle and milk, respectively. The performance of the method was successfully verified for triclabendazole in muscle by participating in a proficiency study, the method was also applied to incurred liver, muscle and milk samples.