19 resultados para 20-200


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract An HPLC method has been developed and validated for the determination of spironolactone, 7a-thiomethylspirolactone and canrenone in paediatric plasma samples. The method utilises 200 µl of plasma and sample preparation involves protein precipitation followed by Solid Phase Extraction (SPE). Determination of standard curves of peak height ratio (PHR) against concentration was performed by weighted least squares linear regression using a weighting factor of 1/concentration2. The developed method was found to be linear over concentration ranges of 30–1000 ng/ml for spironolactone and 25–1000 ng/ml for 7a-thiomethylspirolactone and canrenone. The lower limit of quantification for spironolactone, 7a-thiomethylspirolactone and canrenone were calculated as 28, 20 and 25 ng/ml, respectively. The method was shown to be applicable to the determination of spironolactone, 7a-thiomethylspirolactone and canrenone in paediatric plasma samples and also plasma from healthy human volunteers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background & Aims: Wide between-center variation in adenoma detection rates (ADRs) was observed in the U.K. Flexible Sigmoidoscopy Screening Trial (overall, 12.1%; range, 8.6%-15.9%; P <0.0001). The aim of this study was to determine whether the observed differences could be attributed to varying performance by endoscopists, to examine the effect of experience on performance, and to identify an attainable, standard ADR to which endoscopists could aspire. 

Methods: Thirteen medical endoscopists, one per trial center, each performed about 3000 examinations (200 per month) using the same equipment and protocol. Overall and monthly ADRs were compared using multivariable logistic regression. 

Results: Differences in ADRs were not explained by patient characteristics, incidence of colorectal cancer in the local population, or the endoscopists' medical specialty or previous experience. Average ADRs increased significantly with screening experience (up to 400 examinations). Endoscopists were classified as higher, intermediate, or lower adenoma detectors, and performance levels were maintained over time. Higher detectors had ADRs of 15% overall (men, 20%; women, 10%) and also detected more adenomas per case (higher/lower detectors, 21.7/10.4 adenomas per :100 examinations). 

Conclusions: The differences in ADRs were due to variation in performance of the endoscopists. Long-term follow-up will determine whether this variation is clinically important. We suggest that the standards in higher detecting centers should be achievable by all endoscopists screening unscreened populations aged older than 55 years. Endoscopists should aim to stay above the lower 95% confidence interval band for 200 examinations (10% overall; 5% in women, 15% in men).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electroless nickel-phosphorus deposits with 5-8 wt% P and 3-5 wt% P were analysed for the effects of continuous heating on the crystallization kinetics and phase transformation behaviour of the deposits. The as-deposited coatings consist of a mixture of amorphous and microcrystalline nickel phases, featuring in their X-ray diffraction patterns. Continuous heating processes to 300C-800C at 20C/min were carried out on the deposits in a differential scanning calorimetric apparatus. The subsequent X-ray diffraction analyses show that the sequence of phase transformation process was: amorphous phase + microcrystalline nickel, f.c.c. nickel + Ni3P stable phases. Preferred orientation of nickel {200} plane developed in the deposits after the heating processes. Differential scanning calorimetry of the deposits indicates that the crystallization temperatures increased with decreasing phosphorus content, and increasing heating rate. Crystallization activation energies of the deposits (230 and 322 kJ/mol, respectively) were calculated using the peak temperatures of crystallization process, from the differential scanning calorimetric curves at the heating rates ranging from 5 to 50C/min. It was found that the deposit with lower phosphorus content has higher activation energy.