44 resultados para 19-184


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, the use of plasma optics to improve temporal pulse contrast has had a remarkable impact on the field of high- power laser-solid density interaction physics. Opening an avenue to previously unachievable plasma density gradients in the high intensity focus, this advance has enabled researchers to investigate new regimes of harmonic generation and ion acceleration. Until now, however, plasma optics for fundamental laser reflection have been used in the sub-relativistic intensity regime (10(15) - 10(16)Wcm(-2)) showing high reflectivity (similar to 70%) and good focusability. Therefore, the question remains as to whether plasma optics can be used for such applications in the relativistic intensity regime (> 10(18)Wcm(-2)). Previous studies of plasma mirrors (PMs) indicate that, for 40 fs laser pulses, the reflectivity fluctuates by an order of magnitude and that focusability of the beam is lost as the intensity is increased above 5 x 10(16)Wcm(-2). However, these experiments were performed using laser pulses with a contrast ratio of similar to 10(7) to generate the reflecting surface. Here, we present results for PM operation using high contrast laser pulses resulting in a new regime of operation - the high contrast plasma mirror (HCPM). In this regime, pulses with contrast ratio > 10(10) are used to form the PM surface at > 10(19)Wcm(-2), displaying excellent spatial filtering, reflected near- field beam profile of the fundamental beam and reflectivities of 60 +/- 5%. Efficient second harmonic generation is also observed with exceptional beam quality suggesting that this may be a route to achieving the highest focusable harmonic intensities. Plasma optics therefore offer the opportunity to manipulate ultra-intense laser beams both spatially and temporally. They also allow for ultrafast frequency up-shifting without detrimental effects due to group velocity dispersion (GVD) or reduced focusability which frequently occur when nonlinear crystals are used for frequency conversion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Certain policy areas with considerable impact on young people's educational experiences and achievements, notably assessment and qualifications, do not involve consultation with young people to any meaningful extent. Findings from a national study, which included focus groups with 243 students in the 14-19 phase, are presented with respect to student consultation and participation in such policy areas. A lack of meaningful consultation regarding what students see as ‘higher level’ policy agendas was found (such as qualifications provision, choice or structure). Students are therefore ‘voiceless’ in relation to major qualifications reforms

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pathways of biotransformation of 4-fluorobiphenyl (4FBP) by the ectomycorrhizal fungus Tylospora fibrilosa and several other mycorrhizal fungi were investigated by using (19)F nuclear magnetic resonance (NMR) spectroscopy in combination with (14)C radioisotope-detected high-performance liquid chromatography ((14)C-HPLC). Under the conditions used in this study T. fibrillosa and some other species degraded 4FBP. (14)C-HPLC profiles indicated that there were four major biotransformation products, whereas (19)F NMR showed that there were six major fluorine-containing products. We confirmed that 4-fluorobiphen-4'-ol and 4-fluorobiphen-3'-ol were two of the major products formed, but no other products were conclusively identified. There was no evidence for the expected biotransformation pathway (namely, meta cleavage of the less halogenated ring), as none of the expected products of this route were found. To the best of our knowledge, this is the first report describing intermediates formed during mycorrhizal degradation of halogenated biphenyls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The range of potential applications for indoor and campus based personnel localisation has led researchers to create a wide spectrum of different algorithmic approaches and systems. However, the majority of the proposed systems overlook the unique radio environment presented by the human body leading to systematic errors and inaccuracies when deployed in this context. In this paper RSSI-based Monte Carlo Localisation was implemented using commercial 868 MHz off the shelf hardware and empirical data was gathered across a relatively large number of scenarios within a single indoor office environment. This data showed that the body shadowing effect caused by the human body introduced path skew into location estimates. It was also shown that, by using two body-worn nodes in concert, the effect of body shadowing can be mitigated by averaging the estimated position of the two nodes worn on either side of the body. © Springer Science+Business Media, LLC 2012.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Aspirin use is associated with reduced risk of, and death from, prostate cancer. Our aim was to determine whether low-dose aspirin use after a prostate cancer diagnosis was associated with reduced prostate cancer-specific mortality.

Methods: A cohort of newly diagnosed prostate cancer patients (1998–2006) was identified in the UK Clinical Practice Research Datalink (confirmed by cancer registry linkage). A nested case–control analysis was conducted using conditional logistic regression to compare aspirin usage in cases (prostate cancer deaths) with up to three controls (matched by age and year of diagnosis).

Results: Post-diagnostic low-dose aspirin use was identified in 52 % of 1,184 prostate cancer-specific deaths and 39 % of 3,531 matched controls (unadjusted OR 1.51, 95 % CI 1.19, 1.90; p < 0.001). After adjustment for confounders including treatment and comorbidities, this association was attenuated (adjusted OR 1.02 95 % CI 0.78, 1.34; p = 0.86). Adjustment for estrogen therapy accounted for the majority of this attenuation. There was also no evidence of dose–response association after adjustments. Compared with no use, patients with 1–11 prescriptions and 12 or more prescriptions had adjusted ORs of 1.07 (95 % CI 0.78, 1.47; p = 0.66) and 0.97 (95 % CI 0.69, 1.37; p = 0.88), respectively. There was no evidence of a protective association between low-dose aspirin use in the year prior to diagnosis and prostate cancer-specific mortality (adjusted OR 1.04 95 % CI 0.89, 1.22; p = 0.60).

Conclusion: We found no evidence of an association between low-dose aspirin use before or after diagnosis and risk of prostate cancer-specific mortality, after potential confounders were accounted for, in UK prostate cancer patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An endocrine disruptor (ED) is an exogenous compound that interferes with the body's endocrine system. Exposure to EDs may result in adverse health effects such as infertility and cancer. EDs are composed of a vast group of chemicals including compounds of natural origin such as phytoestrogens or mycotoxins and a wide range of man-made chemicals such as pesticides. Synthetic compounds may find their way into the food chain where a number of them can biomagnify. Additionally, processing activities and food contact materials may add further to the already existing pool of food contaminants. Thus, our diet is considered to be one of the main exposure routes to EDs. Some precautionary legislation has already been introduced to control production and/or application of some persistent organic pollutants with ED characteristics. However, newly emerging EDs with bioaccumulative properties have recently been reported to appear at lower tiers of the food chain but have not been monitored at the grander scale. Milk and dairy products are a major component of our diet, thus it is important to monitor them for EDs. However, most methods developed to date are devoted to one group of compounds at a time. The UHPLC-MS/MS method described here has been validated according to EC decision 2002/657/EC and allows simultaneous extraction, detection, quantitation and confirmation of 19 EDs in milk. The method calibration range is between 0.50 and 20.0 μg kg with coefficients of determination above 0.99 for all analytes. Precision varied from 4.7% to 23.4% in repeatability and reproducibility studies. Established CCα and CCβ values (0.11-0.67 μg kg) facilitate fast, reliable, quantitative and confirmatory analysis of sub μg kg levels of a range of EDs in milk.