278 resultados para diagnostic fluorescent PCR


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The remarkable stability of microRNAs in biofluids underlies their potential as biomarkers, but their small size presents challenges for detection by RT-qPCR. The heterogeneity of microRNAs, with each one comprising a series of variants or 'isomiRs', adds additional complexity. Presented here are the key considerations for use of RT-qPCR to measure microRNAs and their isomiRs, with a focus on plasma. Modified nucleotides can be incorporated into primer sequences to enhance affinity and provide increased specificity and sensitivity for RT-qPCR assays. Approaches based upon polyA tailing and use of a common oligo(dT)-based reverse transcription oligonucleotide will detect most isomiRs. Conversely, stem-loop RT oligonucleotides and sequence specific probes can enable detection of specific isomiRs of interest. Next generation sequencing of all the products of a microRNA RT-PCR reaction is a promising new approach for both microRNA quantification and characterization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Purpose:Juvenile idiopathic arthritis (JIA) comprises a poorly understood group of chronic, childhood onset, autoimmune diseases with variable clinical outcomes. We investigated whether profiling of the synovial fluid (SF) proteome by a fluorescent dye based, two-dimensional gel (DIGE) approach could distinguish the subset of patients in whom inflammation extends to affect a large number of joints, early in the disease process. The post-translational modifications to candidate protein markers were verified by a novel deglycosylation strategy.Methods:SF samples from 57 patients were obtained around time of initial diagnosis of JIA. At 1 year from inclusion patients were categorized according to ILAR criteria as oligoarticular arthritis (n=26), extended oligoarticular (n=8) and polyarticular disease (n=18). SF samples were labeled with Cy dyes and separated by two-dimensional electrophoresis. Multivariate analyses were used to isolate a panel of proteins which distinguish patient subgroups. Proteins were identified using MALDI-TOF mass spectrometry with vitamin D binding protein (VDBP) expression and siaylation further verified by immunohistochemistry, ELISA test and immunoprecipitation. Candidate biomarkers were compared to conventional inflammation measure C-reactive protein (CRP). Sialic acid residues were enzymatically cleaved from immunopurified SF VDBP, enriched by hydrophilic interaction liquid chromatography (HILIC) and analysed by mass spectrometry.Results:Hierarchical clustering based on the expression levels of a set of 23 proteins segregated the extended-to-be oligoarticular from the oligoarticular patients. A cleaved isoform of VDBP, spot 873, is present at significantly reduced levels in the SF of oligoarticular patients at risk of disease extension, relative to other subgroups (p<0.05). Conversely total levels of vitamin D binding protein are elevated in plasma and ROC curves indicate an improved diagnostic sensitivity to detect patients at risk of disease extension, over both spot 873 and CRP levels. Sialysed forms of intact immunopurified VDBP were more prevalent in persistent oligoarticular patient synovial fluids.Conclusion:The data indicate that a subset of the synovial fluid proteome may be used to stratify patients to determine risk of disease extension. Reduced conversion of VDBP to a macrophage activation factor may represent a novel pathway contributing to increased risk of disease extension in JIA patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluating the ratio of selected helium lines allows for measurement of electron densities and temperatures. This technique is applied for L-mode plasmas at TEXTOR (O. Schmitz et al., Plasma Phys. Control. Fusion 50 (2008) 115004). We report our first efforts to extend it to H-mode plasma diagnostics in DIII-D. This technique depends on the accuracy of the atomic data used in the collisional radiative model (CRM). We present predictions for the electron temperatures and densities by using recently calculated R-Matrix With Pseudostates (RMPS) and Convergent Close-Coupling (CCC) electron-impact excitation and ionization data. We include contributions from higher Rydberg states by means of the projection matrix. These effects become significant for high electron density conditions, which are typical in H-mode. We apply a non-equilibrium model for the time propagation of the ionization balance to predict line emission profiles from experimental H-mode data from DIII-D. © 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present complete collisional-radiative modelling results for the soft x-ray emission lines of Fe16+ in the 15 Å–17 Å range. These lines have been the subject of much controversy in the astrophysical and laboratory plasma community. Radiative transition rates are generated from fully relativistic atomic structure calculations. Electron-impact excitation cross sections are determined using a fully relativistic R-matrix method employing 139 coupled atomic levels through n = 5. We find that, in all cases, using a simple ratio of the collisional rate coefficient times a radiative branching factor is not sufficient to model the widely used diagnostic line ratios. One has to include the effects of collisional-radiative cascades in a population model to achieve accurate line ratios. Our line ratio results agree well with several previous calculations and reasonably well with tokamak experimental measurements, assuming a Maxwellian electron-energy distribution. Our modelling results for four EBIT line ratios, assuming a narrow Gaussian electron-energy distribution, are in generally poor agreement with all four NIST measurements but are in better agreement with the two LLNL measurements. These results suggest the need for an investigation of the theoretical polarization calculations that are required to interpret the EBIT line ratio measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spectroscopic studies of line emission intensities and ratios offer an attractive option in the\r\ndevelopment of non-invasive plasma diagnostics. Evaluating ratios of selected He I line\r\nemission profiles from the singlet and triplet neutral helium spin systems allows for simultaneous\r\nmeasurement of electron density (ne) and temperature (Te) profiles. Typically, this powerful\r\ndiagnostic tool is limited by the relatively long relaxation times of the 3S metastable term of helium\r\nthat populates the triplet spin system, and on which electron temperature sensitive lines are based.\r\nBy developing a time dependent analytical solution, we model the time evolution of the two spin\r\nsystems. We present a hybrid time dependent/independent line ratio solution that improves the\r\nrange of application of this diagnostic technique in the scrape-off layer (SOL) and edge plasma\r\nregions when comparing it against the current equilibrium line ratio helium model used at\r\nTEXTOR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electron-impact excitation collision strengths for transitions between all singly excited levels up to the n = 4 shell of helium-Eke argon and the n = 4 and 5 shells of helium-like iron have been calculated using a radiation-damped R-matrix approach. The theoretical collision strengths have been examined and associated with their infinite-energy limit values to allow the preparation of Maxwell-averaged effective collision strengths. These are conservatively considered to be accurate to within 20% at all temperatures, 3 x 10(5)-3 x 10(8) K forAr(16+) and 10(6)-10(9) K for Fe24+. They have been compared with the results of previous studies, where possible, and we find a broad accord. The corresponding rate coefficients are required for use in the calculation of derived, collisional-radiative, effective emission coefficients for helium-like lines for diagnostic application to fusion and astrophysical plasmas. The uncertainties in the fundamental collision data have been used to provide a critical assessment of the expected resultant uncertainties in such derived data, including redistributive and cascade collisional-radiative effects. The consequential uncertainties in the parts of the effective emission coefficients driven by excitation from the ground levels for the key w, x, y and z lines vary between 5% and 10%. Our results remove an uncertainty in the reaction rates of a key class of atomic processes governing the spectral emission of helium-like ions in plasmas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infection is a leading cause of neonatal morbidity and mortality worldwide. Premature neonates are particularly susceptible to infection because of physiologic immaturity, comorbidity, and extraneous medical interventions. Additionally premature infants are at higher risk of progression to sepsis or severe sepsis, adverse outcomes, and antimicrobial toxicity. Currently initial diagnosis is based upon clinical suspicion accompanied by nonspecific clinical signs and is confirmed upon positive microbiologic culture results several days after institution of empiric therapy. There exists a significant need for rapid, objective, in vitro tests for diagnosis of infection in neonates who are experiencing clinical instability. We used immunoassays multiplexed on microarrays to identify differentially expressed serum proteins in clinically infected and non-infected neonates. Immunoassay arrays were effective for measurement of more than 100 cytokines in small volumes of serum available from neonates. Our analyses revealed significant alterations in levels of eight serum proteins in infected neonates that are associated with inflammation, coagulation, and fibrinolysis. Specifically P- and E-selectins, interleukin 2 soluble receptor alpha, interleukin 18, neutrophil elastase, urokinase plasminogen activator and its cognate receptor, and C-reactive protein were observed at statistically significant increased levels. Multivariate classifiers based on combinations of serum analytes exhibited better diagnostic specificity and sensitivity than single analytes. Multiplexed immunoassays of serum cytokines may have clinical utility as an adjunct for rapid diagnosis of infection and differentiation of etiologic agent in neonates with clinical decompensation.