281 resultados para collimation testing
Resumo:
This paper demonstrates the unparalleled value of full scale data which has been acquired from ocean trials of Aquamarine Power’s Oyster 800 Wave Energy Converter (WEC) at the European Marine Energy Centre (EMEC), Orkney, Scotland.
High quality prototype and wave data were simultaneously recorded in over 750 distinct sea states (comprising different wave height, wave period and tidal height combinations) and include periods of operation where the hydraulic Power Take-Off (PTO) system was both pressurised (damped operation) and de-pressurised (undamped operation).
A detailed model-prototype correlation procedure is presented where the full scale prototype behaviour is compared to predictions from both experimental and numerical modelling techniques via a high temporal resolution wave-by-wave reconstruction. This unquestionably provides the definitive verification of the capabilities of such research techniques and facilitates a robust and meaningful uncertainty analysis to be performed on their outputs.
The importance of a good data capture methodology, both in terms of handling and accuracy is also presented. The techniques and procedures implemented by Aquamarine Power for real-time data management are discussed, including lessons learned on the instrumentation and infrastructure required to collect high-value data.
Resumo:
An overview of research on the development of the hybrid test method is presented. The maturity of the hybrid test method is mapped in order to provide context to individual research in the overall development of the test method. In the pseudo dynamic (PsD) test method, the equations of motion are solved using a time stepping numerical integration technique with the inertia and damping being numerically modelled whilst restoring force is physically measured over an extended timescale. Developments in continuous PsD testing led to the real-time hybrid test method and geographically distributed hybrid tests. A key aspect to the efficiency of hybrid testing is the substructuring technique where the critical structural subassemblies that are fundamental to the overall response of the structure are physically tested whilst the remainder of the structure whose response can be more easily predicted is numerically modelled. Much of the early research focused on developing the accuracy and efficiency of the test method, whereas more recently the method has matured to a level where the test method is applied purely as a dynamic testing technique. Developments in numerical integration methods, substructuring, experimental error reduction, delay compensation and speed of testing have led to a test method now in use as full-scale real-time dynamic testing method that is reliable, accurate, efficient and cost effective.
Resumo:
Background Despite the importance of HIV testing for controlling the HIV epidemic, testing rates remain low. Efforts to scale-up testing coverage and frequency in hard-to-reach and at-risk populations commonly focus on home-based HIV testing. This study evaluates the effect of a gift (a food voucher for families, worth US$ 5) on consent rates for home-based HIV testing.
Methods We use data on 18,478 men and women who participated in the 2009 and 2010 population-based HIV surveillance carried out by the Wellcome Trust Africa Centre for Health and Population Studies in rural KwaZulu-Natal, South Africa. Our quasi-experimental difference-in-differences approach controls for unobserved confounding in estimating the causal effect of the intervention on HIV testing consent rates.
Results Allocation of the gift to a family in 2010 increased the probability of family members consenting to test in 2010 by 25 percentage points (95% CI 21-30; p<0.001). The intervention effect persisted, slightly attenuated, in the year following the intervention (2011), further increasing intervention value for money.
Conclusions In HIV hyperendemic settings a gift can be highly effective at increasing consent rates for home-based HIV testing. Given the importance of HIV testing for treatment uptake and individual health, as well as for HIV treatment-and-prevention strategies and for monitoring the population impact of the HIV response, gifts should be considered as a supportive intervention for HIV testing initiatives where consent rates have been low.
Resumo:
The British standard constant-head triaxial test for measuring the permeability of fine-grained soils takes a relatively long time. A quicker test could provide savings to the construction industry, particularly for checking the quality of landfill clay liners. An accelerated permeability test has been developed, but the method often underestimates the permeability values compared owing to structural changes in the soil sample. This paper reports on an investigation
into the accelerated test to discover if the changes can be limited by using a revised procedure. The accelerated test is assessed and compared with the standard test and a ramp-accelerated permeability test. Four different finegrained materials are compacted at various water contents to produce analogous samples for testing using the three different methods. Fabric analysis is carried out on specimens derived from post-test samples using mercury intrusion porosimetry and scanning electron microscopy to assess the effects of testing on soil structure. The results show that accelerated testing in general underestimates permeability compared with values derived from the standard test, owing to changes in soil structure caused by testing. The ramp-accelerated test is shown to provide an improvement in terms of these structural changes.
Resumo:
Collimated transport of fast electron beam through solid density matter is one of the key issues behind the success of the fast ignition scheme by means of which the required amount of ignition energy can be delivered to the hot spot region of the compressed fuel. Here we report on a hot electron beam collimation scheme in solids by tactfully using the strong magnetic fields generated by an electrical resistivity gradient according to Faraday's law. This was accomplished by appropriately fabricating the targets in such a way that the electron beam is directed to flow in a metal which is embedded in a much lower resistivity and atomic number metal. Experimental results showed guided transport of hot electron beam over hundreds of microns length inside solid density plasma, which were obtained from two experiments examining the scheme for petawatt laser driven hot electron beam while employing various target configurations.
Resumo:
There is a dearth of evidence focusing on student preferences for computer-based testing versus
testing via student response systems for summative assessment in undergraduate education.
This quantitative study compared the preference and acceptability of computer-based testing
and a student response system for completing multiple choice questions in undergraduate
nursing education. After using both computer-based testing and a student response system to
complete multiple choice questions, 192 first year undergraduate nursing students rated their
preferences and attitudes towards using computer-based testing and a student response system.
Results indicated that seventy four percent felt the student response system was easy to use.
Fifty six percent felt the student response system took more time than the computer-based testing
to become familiar with. Sixty Percent felt computer-based testing was more users friendly.
Seventy Percent of students would prefer to take a multiple choice question summative exam
via computer-based testing, although Fifty percent would be happy to take using student response
system. Results are useful for undergraduate educators in relation to student’s preference
for using computer-based testing or student response system to undertake a summative
multiple choice question exam
Resumo:
By testing a simple asset pricing model of heterogeneous agents to characterize the power-law behavior of the DAX 30 from 1975 to 2007, we provide supporting evidence on empirical findings that investors and fund managers use combinations of fixed and switching strategies based on fundamental and technical analysis when making investment decisions. By conducting econometric analysis via Monte Carlo simulations, we show that the autocorrelation patterns, the estimates of the power-law decay indices, (FI)GARCH parameters, and tail index of the model match closely the corresponding estimates for the DAX 30. A mechanism analysis based on the calibrated model provides further insights into the explanatory power of heterogeneous agent models.