263 resultados para Syndrome de fatigue chronique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sepsis is a common condition that is associated with significant morbidity, mortality and health-care cost. Pulmonary and non-pulmonary sepsis are common causes of the acute respiratory distress syndrome (ARDS). The mortality from ARDS remains high despite protective lung ventilation, and currently there are no specific pharmacotherapies to treat sepsis or ARDS. Sepsis and ARDS are characterised by activation of the inflammatory cascade. Although there is much focus on the study of the dysregulated inflammation and its suppression, the associated activation of the haemostatic system has been largely ignored until recently. There has been extensive interest in the role that platelet activation can have in the inflammatory response through induction, aggregation and activation of leucocytes and other platelets. Aspirin can modulate multiple pathogenic mechanisms implicated in the development of multiple organ dysfunction in sepsis and ARDS. This review will discuss the role of the platelet, the mechanisms of action of aspirin in sepsis and ARDS, and aspirin as a potential therapy in treating sepsis and ARDS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Importance Limited information exists about the epidemiology, recognition, management, and outcomes of patients with the acute respiratory distress syndrome (ARDS).

Objectives To evaluate intensive care unit (ICU) incidence and outcome of ARDS and to assess clinician recognition, ventilation management, and use of adjuncts—for example prone positioning—in routine clinical practice for patients fulfilling the ARDS Berlin Definition.

Design, Setting, and Participants The Large Observational Study to Understand the Global Impact of Severe Acute Respiratory Failure (LUNG SAFE) was an international, multicenter, prospective cohort study of patients undergoing invasive or noninvasive ventilation, conducted during 4 consecutive weeks in the winter of 2014 in a convenience sample of 459 ICUs from 50 countries across 5 continents.

Exposures Acute respiratory distress syndrome.

Main Outcomes and Measures The primary outcome was ICU incidence of ARDS. Secondary outcomes included assessment of clinician recognition of ARDS, the application of ventilatory management, the use of adjunctive interventions in routine clinical practice, and clinical outcomes from ARDS.

Results Of 29 144 patients admitted to participating ICUs, 3022 (10.4%) fulfilled ARDS criteria. Of these, 2377 patients developed ARDS in the first 48 hours and whose respiratory failure was managed with invasive mechanical ventilation. The period prevalence of mild ARDS was 30.0% (95% CI, 28.2%-31.9%); of moderate ARDS, 46.6% (95% CI, 44.5%-48.6%); and of severe ARDS, 23.4% (95% CI, 21.7%-25.2%). ARDS represented 0.42 cases per ICU bed over 4 weeks and represented 10.4% (95% CI, 10.0%-10.7%) of ICU admissions and 23.4% of patients requiring mechanical ventilation. Clinical recognition of ARDS ranged from 51.3% (95% CI, 47.5%-55.0%) in mild to 78.5% (95% CI, 74.8%-81.8%) in severe ARDS. Less than two-thirds of patients with ARDS received a tidal volume 8 of mL/kg or less of predicted body weight. Plateau pressure was measured in 40.1% (95% CI, 38.2-42.1), whereas 82.6% (95% CI, 81.0%-84.1%) received a positive end-expository pressure (PEEP) of less than 12 cm H2O. Prone positioning was used in 16.3% (95% CI, 13.7%-19.2%) of patients with severe ARDS. Clinician recognition of ARDS was associated with higher PEEP, greater use of neuromuscular blockade, and prone positioning. Hospital mortality was 34.9% (95% CI, 31.4%-38.5%) for those with mild, 40.3% (95% CI, 37.4%-43.3%) for those with moderate, and 46.1% (95% CI, 41.9%-50.4%) for those with severe ARDS.

Conclusions and Relevance Among ICUs in 50 countries, the period prevalence of ARDS was 10.4% of ICU admissions. This syndrome appeared to be underrecognized and undertreated and associated with a high mortality rate. These findings indicate the potential for improvement in the management of patients with ARDS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background
Fluid administration to critically ill patients remains the subject of considerable controversy. While intravenous fluid given for resuscitation may be life-saving, a positive fluid balance over time is associated with worse outcomes in critical illness. The aim of this systematic review is to summarise the existing evidence regarding the relationship between fluid administration or balance and clinically important patient outcomes in critical illness.

Methods
We will search Medline, EMBASE, the Cochrane Central Register of Controlled Trials from 1980 to the present and key conference proceedings from 2009 to the present. We will include studies of critically ill adults and children with acute respiratory distress syndrome (ARDS), sepsis and systemic inflammatory response syndrome (SIRS). We will include randomised controlled trials comparing two or more fluid regimens of different volumes of fluid and observational studies reporting the relationship between volume of fluid administered or fluid balance and outcomes including mortality, lengths of intensive care unit and hospital stay and organ dysfunction. Two independent reviewers will assess articles for eligibility, data extraction and quality appraisal. We will conduct a narrative and/or meta-analysis as appropriate.

Discussion
While fluid management has been extensively studied and discussed in the critical care literature, no systematic review has attempted to summarise the evidence for post-resuscitation fluid strategies in critical illness. Results of the proposed systematic review will inform practice and the design of future clinical trials.

Systematic review registration
PROSPERO CRD42013005608. (http://​www.​crd.​york.​ac.​uk/​PROSPERO/​)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose
– Concern of the deterioration of indoor environmental quality as a result of energy efficient building design strategies is growing. Apprehensions of the effect of airtight, super insulated envelopes, the reduction of infiltration, and the reliance on mechanical systems to provide adequate ventilation (air supply) is promoting emerging new research in this field. The purpose of this paper is to present the results of an indoor air quality (IAQ) and thermal comfort investigation in UK energy efficient homes, through a case study investigation.

Design/methodology/approach
– The case study dwellings consisted of a row of six new-build homes which utilize mechanical ventilation with heat recovery (MVHR) systems, are built to an average airtightness of 2m3/m2/hr at 50 Pascal’s, and constructed without a central heating system. Physical IAQ measurements and occupant interviews were conducted during the summer and winter months over a 24-hour period, to gain information on occupant activities, perception of the interior environment, building-related health and building use.

Findings
– The results suggest inadequate IAQ and perceived thermal comfort, insufficient use of purge ventilation, presence of fungal growth, significant variances in heating patterns, occurrence of sick building syndrome symptoms and issues with the MVHR system.

Practical implications
– The findings will provide relevant data on the applicability of airtight, mechanically ventilated homes in a UK climate, with particular reference to IAQ.

Originality/value
– IAQ data of this nature is essentially lacking, particularly in the UK context. The findings will aid the development of effective sustainable design strategies that are appropriate to localized climatic conditions and sensitive to the health of building occupants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corrosion fatigue is a fracture process as a consequence of synergistic interactions between the material structure, corrosive environment and cyclic loads/strains. It is difficult to be detected and can cause unexpected failure of engineering components in use. This study reveals a comparison of corrosion fatigue behaviour of laser-welded and bare NiTi wires using bending rotation fatigue (BRF) test coupled with a specifically-designed corrosion cell. The testing medium was Hanks’ solution (simulated body fluid) at 37.5 oC. Electrochemical impedance spectroscopic (EIS) measurement was carried out to monitor the change of corrosion resistance of sample during the BRF test at different periods of time. Experiments indicate that the laser-welded NiTi wire would be more susceptible to the corrosion fatigue attack than the bare NiTi wire. This study can serve as a benchmark for the product designers and engineers to understand the corrosion fatigue behaviour of the NiTi laser weld joint and determine the fatigue life safety factor for NiTi medical devices/implants involving laser welding in the fabrication process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute respiratory distress syndrome presents as hypoxia and bilateral pulmonary infiltrates on chest imaging in the absence of heart failure sufficient to account for this clinical state. Management is largely supportive, and is focused on protective mechanical ventilation and the avoidance of fluid overload. Patients with severe hypoxaemia can be managed with early short-term use of neuromuscular blockade, prone position ventilation, or extracorporeal membrane oxygenation. The use of inhaled nitric oxide is rarely indicated and both β2 agonists and late corticosteroids should be avoided. Mortality remains at approximately 30%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Proposals to implement fatigue-management strategies in residency education assume that medicine shares the view
of other risk-adverse industries that fatigue is hazardous. This view is an essential underpinning of fatigue-management strategies
that other industries have embedded as part of their workplace occupational health and safety programs. We sought to explore how
residents understand fatigue in the context of their training environment.

Methods: We interviewed 21 residents in 7 surgical and nonsurgical programs at Western University in 2014. All participants met the
inclusion criteria of routinely working 24-hour call shifts while enrolled in their training program. Data collection and analysis occurred iteratively in keeping with constructivist grounded theory methodology and informed theoretical sampling to sufficiency.

Results: Four predominant principles of fatigue captured how the social learning environment shaped residents’ perceptions of
fatigue. These included the conceptualization of fatigue as (a) inescapable and therefore accepted, (b) manageable through experience, (c) necessary for future practice and (d) surmountable when required.

Interpretation: This study elaborates our understanding of how principles of fatigue are constructed and reinforced by the training
environment. Whereas fatigue is seen as a collective hazard in other industries, our data showed that, in residency training, fatigue
may be seen as a personal challenge. Consequently, fatigue-management strategies that conceptualize fatigue as an occupational
threat may have a limited impact on resident behaviour and patient safety.