286 resultados para Standardised testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

High temperature ceramic membranes have interesting possibilities for application in areas of new and developing technologies such as hydrocarbon combustion with carbon dioxide capture and electrochemical promotion of catalysis (EPOC). However, membrane module sealing remains a significant technical challenge. In this work a borosilicate glass sealant (50SiO2·25B2O3·25Na2O, mol%) was developed to fit the requirements of sealing an air separation membrane system at intermediate temperatures (300-600 °C). The seal was assessed by testing the leak rates under a range of conditions. The parameters tested included the effect of flowrate on the leak rate, the heating and cooling rates of the reactor and the range of temperatures under which the system could operate. Tests for durability and reliability were also performed. It was found that the most favourable reactor configuration employed a reactor with the ceramic pellet placed underneath the inner chamber alumina tube (inverted configuration), using a quartz wool support to keep the membrane in place prior to sealing. Using this configuration the new glass-based seal was found to be a more suitable sealant than traditional alternatives; it produced lower leak rates at all desirable flowrates, with the potential for rapid heating and cooling and multiple cycling, allowing for prolonged usage. © 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Producing concrete with secondary raw materials is an excellent way to contribute to a moresustainable world, provided that this concrete has at least the same performance during itsservice life as concrete made with the primary raw materials it replaces. Secondary rawmaterials for Light Weight (LW) aggregates (rigid polyurethane foams, shredded tire rubberand mixed plastic scraps) have been combined with secondary raw materials for the binder(fly ash, slag and perlite tailings) making sustainable concretes that were investigated fortheir suitability as LW, highly insulating concrete for four different types of applications.Compliance to desired engineering properties (workability, setting time) was not alwaysfeasible: it was mostly the low workability of the mixtures that limited their application.Contrary to well established cements, steering the workability by adding water was not anoption for these binders that rely on alkali-activation. Eight successful mixtures have beentested further. The results have shown that it is possible to produce a non-structuralsustainable concrete with good mechanical and thermal insulation properties.Design of concrete made with novel materials is currently not feasible without extensiveexperimentation as no design rules exist other than empirically derived rules based ontraditional materials. As a radical different approach, a flexible concrete mix design has beendeveloped with which the concrete can be modelled in the fresh and hardened state. Thenumerical concrete mix design method proves a promising tool in designing concrete forperformance demands such as elasticity parameters and thermal conductivity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cognitive reflection test (CRT) is a short measure of a person's ability to resist intuitive response tendencies and to produce a normatively correct response, which is based on effortful reasoning. Although the CRT is a very popular measure, its psychometric properties have not been extensively investigated. A major limitation of the CRT is the difficulty of the items, which can lead to floor effects in populations other than highly educated adults. The present study aimed at investigating the psychometric properties of the CRT applying item response theory analyses (a two-parameter logistic model) and at developing a new version of the scale (the CRT-long), which is appropriate for participants with both lower and higher levels of cognitive reflection. The results demonstrated the good psychometric properties of the original, as well as the new scale. The validity of the new scale was also assessed by measuring correlations with various indicators of intelligence, numeracy, reasoning and decision-making skills, and thinking dispositions. Moreover, we present evidence for the suitability of the new scale to be used with developmental samples. Finally, by comparing the performance of adolescents and young adults on the CRT and CRT-long, we report the first investigation into the development of cognitive reflection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Tiotropium is a once-daily, long-acting anticholinergic bronchodilator with the potential to alleviate airway obstruction in cystic fibrosis. Our objective was to evaluate the efficacy and safety of 2.5 and 5 μg once-daily tiotropium delivered via the Respimat Soft Mist Inhaler vs. placebo in people with cystic fibrosis. Methods: This phase 2, 12-week, randomized, double-blind, placebo-controlled parallel-group study of tiotropium Respimat as add-on to usual cystic fibrosis maintenance therapy included people with cystic fibrosis with pre-bronchodilator forced expiratory volume in 1 second (FEV1) ≥25% predicted. Co-primary efficacy end points were change from baseline in percent-predicted FEV1area under the curve from 0 to 4 hours (FEV1AUC0-4h), and trough FEV1at the end of week 12. Findings: A total of 510 subjects with cystic fibrosis aged 5-69 years were randomized. Both doses of tiotropium resulted in significant improvement compared with placebo in the co-primary efficacy end points at the end of week 12 (change from baseline in percent-predicted FEV1AUC0-4h: 2.5 μg: 2.94%, 95% confidence interval 1.19-4.70, p = 0.001; 5 μg: 3.39%, 95% confidence interval 1.67-5.12, p = 0.0001; in percent-predicted trough FEV1:2.5 μg: 2.24%, p = 0.2; 5 μg: 2.22%, p = 0.02). There was a greater benefit with tiotropium 5 vs. 2.5 μg. No treatment-related adverse events or unexpected safety findings were observed in patients taking tiotropium. Conclusions: Tiotropium significantly improved lung function in people with cystic fibrosis. The improvement was greater with the higher dose than the lower dose, with no difference in adverse events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper addresses the quality of the interface and edge bonded joints in layers of cross-laminated timber (CLT) panels. The shear performance was studied to assess the suitability of two different adhesives, Polyurethane (PUR) and Phenol-Resorcinol-Formaldehyde (PRF), and to determine the optimum clamping pressure. Since there is no established testing procedure to determine the shear strength of the surface bonds between layers in a CLT panel, block shear tests of specimens in two different configurations were carried out, and further shear tests of edge bonded specimen in two configurations were performed. Delamination tests were performed on samples which were subjected to accelerated aging to assess the durability of bonds in severe environmental conditions. Both tested adhesives produced boards with shear strength values within the edge bonding requirements of prEN 16351 for all manufacturing pressures. While the PUR specimens had higher shear strength values, the PRF specimens demonstrated superior durability characteristics in the delamination tests. It seems that the test protocol introduced in this study for crosslam bonded specimens, cut from a CLT panel, and placed in the shearing tool horizontally, accurately reflects the shearing strength of glue lines in CLT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report summarizes our results from security analysis covering all 57 competitions for authenticated encryption: security, applicability, and robustness (CAESAR) first-round candidates and over 210 implementations. We have manually identified security issues with three candidates, two of which are more serious, and these ciphers have been withdrawn from the competition. We have developed a testing framework, BRUTUS, to facilitate automatic detection of simple security lapses and susceptible statistical structures across all ciphers. From this testing, we have security usage notes on four submissions and statistical notes on a further four. We highlight that some of the CAESAR algorithms pose an elevated risk if employed in real-life protocols due to a class of adaptive-chosen-plaintext attacks. Although authenticated encryption with associated data are often defined (and are best used) as discrete primitives that authenticate and transmit only complete messages, in practice, these algorithms are easily implemented in a fashion that outputs observable ciphertext data when the algorithm has not received all of the (attacker-controlled) plaintext. For an implementor, this strategy appears to offer seemingly harmless and compliant storage and latency advantages. If the algorithm uses the same state for secret keying information, encryption, and integrity protection, and the internal mixing permutation is not cryptographically strong, an attacker can exploit the ciphertext–plaintext feedback loop to reveal secret state information or even keying material. We conclude that the main advantages of exhaustive, automated cryptanalysis are that it acts as a very necessary sanity check for implementations and gives the cryptanalyst insights that can be used to focus more specific attack methods on given candidates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The channel-based model of duration perception postulates the existence of neural mechanisms that respond selectively to a narrow range of stimulus durations centred on their preferred duration (Heron et al Proceedings of the Royal Society B 279 690–698). In principle the channel-based model could
explain recent reports of adaptation-induced, visual duration compression effects (Johnston et al Current Biology 16 472–479; Curran and Benton Cognition 122 252–257); from this perspective duration compression is a consequence of the adapting stimuli being presented for a longer duration than the test stimuli. In the current experiment observers adapted to a sequence of moving random dot patterns at the same retinal position, each 340ms in duration and separated by a variable (500–1000ms) interval. Following adaptation observers judged the duration of a 600ms test stimulus at the same location. The test stimulus moved in the same, or opposite, direction as the adaptor. Contrary to the channel-based
model’s prediction, test stimulus duration appeared compressed, rather than expanded, when it moved in the same direction as the adaptor. That test stimulus duration was not distorted when moving in the opposite direction further suggests that visual timing mechanisms are influenced by additional neural processing associated with the stimulus being timed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of biological tissues in the in vitro assessments of dissolving (?) microneedle (MN) array mechanical strength and subsequent drug release profiles presents some fundamental difficulties, in part due to inherent variability of the biological tissues employed. As a result, these biological materials are not appropriate for routine used in industrial formulation development or quality control (QC) tests. In the present work a facile system using Parafilm M® (PF) to test drug permeation performance using dissolving MN arrays is proposed. Dissolving MN arrays containing 196 needles (600 μm needle height) were inserted into a single layer of PF and a hermetic “pouch” was created including the array inside. The resulting system was placed in a dissolution bath and the release of model molecules was evaluated. Different MN formulations were tested using this novel setup, releasing between 40 and 180 µg of their cargos after 6 hours. The proposed system is a more realistic approach for MN testing than the typical performance test described in the literature for conventional transdermal patches. Additionally, the use of PF membrane was tested either in the hermetic “pouch” and using Franz Cell methodology yielding comparable release curves. Microscopy was used in order to ascertain the insertion of the different MN arrays in the PF layer. The proposed system appears to be a good alternative to the use of Franz cells in order to compare different MN formulations. Given the increasing industrial interest in MN technology, the proposed system has potential as a standardised drug/active agent release test for quality control purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Clostridium difficile (C. difficile) is a leading cause of infectious diarrhoea in hospitals. Sending faecal samples for testing expedites diagnosis and appropriate treatment. Clinical suspicion of C. difficile based on patient history, signs and symptoms is the basis for sampling. Sending faecal samples from patients with diarrhoea ‘just in case’ the patient has C. difficile may be an indication of poor clinical management.

Aim: To evaluate the effectiveness of an intervention by an Infection Prevention and Control Team (IPCT) in reducing inappropriate faecal samples sent for C. difficile testing.

Method: An audit of numbers of faecal samples sent before and after a decision-making algorithm was introduced. The number of samples received in the laboratory was retrospectively counted for 12-week periods before and after an algorithm was introduced.
Findings: There was a statistically significant reduction in the mean number of faecal samples sent post the algorithm. Results were compared to a similar intervention carried out in 2009 in which the same message was delivered by a memorandum. In 2009 the memorandum had no effect on the overall number of weekly samples being sent.

Conclusion: An algorithm intervention had an effect on the number of faecal samples being sent for C. difficile testing and thus contributed to the effective use of the laboratory service.