312 resultados para Slot antenna arrays


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate, for the first time, the influence of pharmacist intervention and the use of a patient information leaflet on self-application of hydrogel-forming microneedle arrays by human volunteers without the aid of an applicator device.
Methods: A patient information leaflet was drafted and pharmacist counselling strategy devised. Twenty human volunteers applied 11 × 11 arrays of 400 μm hydrogel-forming microneedle arrays to their own skin following the instructions provided. Skin barrier function disruption was assessed using transepidermal water loss measurements and optical coherence tomography and results compared to those obtained when more experienced researchers applied the microneedles to the volunteers or themselves.
Results: Volunteer self-application of the 400 μm microneedle design resulted in an approximately 30% increase in skin transepidermal water loss, which was not significantly different from that seen with self-application by the more experienced researchers or application to the volunteers. Use of optical coherence tomography showed that self-application of microneedles of the same density (400 μm, 600 μm and 900 μm) led to percentage penetration depths of approximately 75%, 70% and 60%, respectively, though the diameter of the micropores created remained quite constant at approximately 200 μm. Transepidermal water loss progressively increased with increasing height of the applied microneedles and this data, like that for penetration depth, was consistent, regardless of applicant.
Conclusion: We have shown that hydrogel-forming microneedle arrays can be successfully and reproducibly applied by human volunteers given appropriate instruction. If these outcomes were able to be extrapolated to the general patient population, then use of bespoke MN applicator devices may not be necessary, thus possibly enhancing patient compliance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Engineering plasmonic nanomaterials or nanostructures towards ultrasensitive biosensing for disease markers or pathogens is of high importance. Here we demonstrate a systematic approach to tailor effective plasmonic nanorod arrays by combining both comprehensive numerical discrete dipole approximations (DDA) simulation and transmission spectroscopy experiments. The results indicate that 200×50 nm nanorod arrays with 300×500 nm period provide the highest FOM of 2.4 and a sensitivity of 310 nm/RIU. Furthermore, we demonstrate the use of nanorod arrays for the detection of single nucleotide polymorphism in codon 12 of the K-ras gene that are frequently occurring in early stages of colon cancer, with a sensitivity down to 10 nM in the presence of 100-fold higher concentration of the homozygous genotypes. Our work shows significant potential of nanorod arrays towards point-of-care applications in diagnosis and clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we present core–shell nanowire arrays of gold coated with a nanometric layer of cobalt. Despite the extremely small Co volume, these core–shell nanowires display large magneto-optical activity and plasmonic resonance determined by the geometry of the structure. Therefore, we are able to tune both the plasmonic and magneto-optical response in the visible range. Through optical and ellipsometric measurements in transmission, and applying a magnetic field to the sample, it is possible to modulate the value of the phase angle (Del {Δ}) between the S and P polarised components. It was found that the core–shell sample produced an order of magnitude larger variation in Del with changing magnetic field direction, compared with hollow cobalt tubes. The enhancement of magneto optical properties through the plasmonic nature of the gold core is complemented with the ability to induce magnetic influence over optical properties via an externally applied field. Moreover, we demonstrate for the first time the ability to use the remanent magnetisation of the Co, in conjunction with the optical properties defined by the Au, to observe remanent optical states in this uniquely designed structure. This new class of magnetoplasmonic metamaterial has great potential in a wide range of applications, from bio-sensing to data storage due to the tuneable nature of multiple resonance modes and dual functionality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The properties of metasurfaces composed of doubly periodic arrays of interwoven quadrifilar spiral conductors on magnetized ferrite substrates have been investigated with the aid of the full-wave electromagnetic simulator. The effects of incident wave polarization and ferrite magnetization on the scattering characteristics have been analysed at both normal and in-plane dc magnetic bias. The features of the fundamental topological resonances in the interwoven spiral arrays on ferrite substrates are illustrated by the simulation results and the effects of ferrite gyrotropy and dispersion on the array resonance response and fractional bandwidth are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The propagation of UWB signals for body-centric communications within a modern classroom/conference room environment was investigated. Presented results demonstrate that the body-antenna mounting position has a marked impact on the received power levels and positioning the antenna on the chest as opposed to the shoulder or wrist creates more extreme values in receive power, mean excess delay and rms delay spread. Additionally, the best fit models for each scenario are presented and highlight the difference between the chest and other compared antenna locations. The work concluded that the chest is a poor choice of mounting position for the antenna due to significant body shadowing effects, with the wrist or shoulder considered better options for UWB systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low-profile wearable antenna suitable for integration into low-cost, disposable medical vital signs monitors is presented. Simulated and measured antenna performance was characterized on a layered human tissue phantom, representative of the thorax region of a range of human bodies. The wearable antenna has sufficient bandwidth for the 868 MHz Industrial, Scientific and Medical frequency band. Wearable radiation efficiency of up to 30 % is reported when mounted in close proximity to the novel human tissue phantom antenna test-bed at 868 MHz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel dual-band printed diversity antenna is proposed and studied. The antenna, which consists of two back-to- back monopoles with symmetric configuration, is printed on a printed circuit board. The effects of some important parameters of the proposed antenna are deeply studied and the design methodology is given. A prototype of the proposed antenna operating at UMTS (1920-2170 MHz) and 2.4-GHz WLAN (2400-2484 MHz) bands is provided to demonstrate the usability of the methodology in dual-band diversity antenna for mobile terminals. In the above two bands, the isolations of the prototype are larger than 13 dB and 16 dB, respectively. The measured radiation patterns of the two monopoles in general cover complementary space regions. The diversity performance is also evaluated by calculating the envelope correlation coefficient, the mean effective gains of the antenna elements and the diversity gain. It is proved that the proposed antenna can provide spatial and pattern diversity to combat multipath fading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of biosensors attached to the body for health monitoring is now readily accepted, and the merits of such systems and their potential impact on healthcare receive much attention. Wearable medical systems used in clinical applications to monitor vital signs must be comfortable to wear, yet have robust performance to ensure reliable communications links. Additionally, and vital to the success of these innovations, is that these solutions are disposable to avoid risk of patient infection and this means that they must be ultra-low cost. Antennas optimized for printing using conductive inks offer new exciting advances in making a truly disposable solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this letter, a multiantenna system with four printed monopoles is presented. The monopoles that occupy relatively small area are positioned at the four corners of a printed circuit board, so that the four-element antenna system can be equipped on the lid of a folder-type mobile phone, leaving enough space for the circuits and reducing the effect of human hands. Based on simulation, a prototype for the Universal Mobile Telecommunications System (UMTS) operation has been constructed and tested. The measured -10-dB impedance bandwidths of the four elements are larger than 320 MHz with higher than 11.5-dB isolation. Moreover, the proposed antenna can provide spatial and pattern diversity in a diversity/multiple-input-multiple-output (MIMO) system.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interweaving planar spiral conductors in doubly periodic arrays enable substantially sub-wavelength resonant response along with broadening fractional bandwidth. A self-contained analytical model is proposed to accurately predict the characteristics of the intertwined quadrifilar spiral array near the fundamental resonance. The model, based upon a multiconductor transmission line (MTL) approach, provides physical insight into the unique properties of the distributed interactions between the interleaved counter-wound spiral arms extended beyond a single unit cell and elucidates the mechanisms underlying the array performance at normal and oblique incidence of TE and TM polarised waves. The developed MTL model is instrumental in the design of the artificial surfaces with the specified response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high impedance metasurface (HIMS) composed of the arrays of intertwined planar spirals on thin (~0.1λ) ferrite-dielectric substrate is proposed. The HIMS exhibits fractional bandwidth in excess of 10% and excellent angular and polarisation stability of the circular polarised waves at oblique incidence.