300 resultados para Rhodes, John Nicholas, 1809-1842.
Resumo:
OBJECTIVE: To assess the impedance cardiogram recorded by an automated external defibrillator during cardiac arrest to facilitate emergency care by lay persons. Lay persons are poor at emergency pulse checks (sensitivity 84%, specificity 36%); guidelines recommend they should not be performed. The impedance cardiogram (dZ/dt) is used to indicate stroke volume. Can an impedance cardiogram algorithm in a defibrillator determine rapidly circulatory arrest and facilitate prompt initiation of external cardiac massage?
DESIGN: Clinical study.
SETTING: University hospital.
PATIENTS: Phase 1 patients attended for myocardial perfusion imaging. Phase 2 patients were recruited during cardiac arrest. This group included nonarrest controls.
INTERVENTIONS: The impedance cardiogram was recorded through defibrillator/electrocardiographic pads oriented in the standard cardiac arrest position.
MEASUREMENTS AND MAIN RESULTS: Phase 1: Stroke volumes from gated myocardial perfusion imaging scans were correlated with parameters from the impedance cardiogram system (dZ/dt(max) and the peak amplitude of the Fast Fourier Transform of dZ/dt between 1.5 Hz and 4.5 Hz). Multivariate analysis was performed to fit stroke volumes from gated myocardial perfusion imaging scans with linear and quadratic terms for dZ/dt(max) and the Fast Fourier Transform to identify significant parameters for incorporation into a cardiac arrest diagnostic algorithm. The square of the peak amplitude of the Fast Fourier Transform of dZ/dt was the best predictor of reduction in stroke volumes from gated myocardial perfusion imaging scans (range = 33-85 mL; p = .016). Having established that the two pad impedance cardiogram system could detect differences in stroke volumes from gated myocardial perfusion imaging scans, we assessed its performance in diagnosing cardiac arrest. Phase 2: The impedance cardiogram was recorded in 132 "cardiac arrest" patients (53 training, 79 validation) and 97 controls (47 training, 50 validation): the diagnostic algorithm indicated cardiac arrest with sensitivities and specificities (+/- exact 95% confidence intervals) of 89.1% (85.4-92.1) and 99.6% (99.4-99.7; training) and 81.1% (77.6-84.3) and 97% (96.7-97.4; validation).
CONCLUSIONS: The impedance cardiogram algorithm is a significant marker of circulatory collapse. Automated defibrillators with an integrated impedance cardiogram could improve emergency care by lay persons, enabling rapid and appropriate initiation of external cardiac massage.
Resumo:
OBJECTIVE: Laypersons are poor at emergency pulse checks (sensitivity 84%, specificity 36%). Guidelines indicate that pulse checks should not be performed. The impedance cardiogram (dZ/dt) is used to assess stroke volume. Can a novel defibrillator-based impedance cardiogram system be used to distinguish between circulatory arrest and other collapse states?
DESIGN: Animal study.
SETTING: University research laboratory.
SUBJECTS: Twenty anesthetized, mechanically ventilated pigs, weight 50-55 kg.
INTERVENTIONS: Stroke volume was altered by right ventricular pacing (160, 210, 260, and 305 beats/min). Cardiac arrest states were then induced: ventricular fibrillation (by rapid ventricular pacing) and, after successful defibrillation, pulseless electrical activity and asystole (by high-dose intravenous pentobarbitone).
MEASUREMENTS AND MAIN RESULTS: The impedance cardiogram was recorded through electrocardiogram/defibrillator pads in standard cardiac arrest positions. Simultaneously recorded electro- and impedance cardiogram (dZ/dt) along with arterial blood pressure tracings were digitized during each pacing and cardiac arrest protocol. Five-second epochs were analyzed for sinus rhythm (20 before ventricular fibrillation, 20 after successful defibrillation), ventricular fibrillation (40), pulseless electrical activity (20), and asystole (20), in two sets of ten pigs (ten training, ten validation). Standard impedance cardiogram variables were noncontributory in cardiac arrest, so the fast Fourier transform of dZ/dt was assessed. During ventricular pacing, the peak amplitude of fast Fourier transform of dZ/dt (between 1.5 and 4.5 Hz) correlated with stroke volume (r2 = .3, p < .001). In cardiac arrest, a peak amplitude of fast Fourier transform of dZ/dt of < or = 4 dB x ohm x rms indicated no output with high sensitivity (94% training set, 86% validation set) and specificity (98% training set, 90% validation set).
CONCLUSIONS: As a powerful clinical marker of circulatory collapse, the fast Fourier transformation of dZ/dt (impedance cardiogram) has the potential to improve emergency care by laypersons using automated defibrillators.
Resumo:
Title: Boundary-setting as a core activity in complex public systems
Authors: Joanne Murphy & Mary Lee Rhodes
The definition of the boundary of a system is at the core of any systems approach (Midgley 2000; 2003). By defining boundaries we enable – and delimit – the range of outcomes sought and the actions and resources that can be brought to bear. In complex adaptive systems (CAS) analysis, the conceptualisaion and definition of boundaries is particularly challenging as they are constantly undergoing redefinition through agent action, interaction and entry/exit. (Rhodes et al 2011). The concept of ‘boundaries’ appears regularly in a wide range of literature around public management, administration, geopolitics, regeneration and organisational development. Discussions around boundaries focus on many things from concrete physical manifestations and barriers, to virtual interfaces between one organisational unit and another, or even entirely theoretical demarcations between different schools of thought (Kaboolian, 1998, Levi-Faur, 2004, Agranoff & McGuire, 2004).
However, managing ‘beyond’ such boundaries is a routinely recurring aspiration that transcends sectors and local concerns. Unsurprisingly then, there is an increasing understanding of the need to acknowledge and manage such boundaries (whether they be physical, social or organisational) within public management as a discipline (Currie et al 2007, Fitzsimmons and White, 1997, Murtagh, 2002). This paper explores the impact of boundaries on public management strategic decision-making in the sectors of urban regeneration and healthcare. In particular, it focuses on demarcations to physical space, communal identity and within professional relationships in these sectors.
The first section describes the research that gave rise to the paper and the cases examined. Next we briefly define what we mean by boundaries. We explore issues that have emerged from our analysis of urban regeneration and health care singularly, before looking at how the concept of boundaries is a recurrent concern across the sectors. The main contribution of the paper is an exploration of how a CAS lens can bring a new insight into the concept of boundaries and decision-making in the two sets of case studies. This discussion will concentrate on initial conditions, bifurcation and adaptation as key CAS factors in relation to boundaries. We conclude with a brief discussion on the benefits of a CAS lens to an analysis of boundaries in public management decision-making.
References:
Agranoff, R. and McGuire, M. (2003) Collaborative Public Management: Strategies for Local Government. Washington, DC: Georgetown Univ. Press.
Currie, G., Lockett, A. (2007) “A critique of transformational leadership: moral, professional & contingent dimensions of leadership within public services organizations”. Human Relations 60: 341-370.
Fitzsimmons and White, (1997) "Crossing boundaries: communication between professional groups", Journal of Management in Medicine, Vol. 11 Iss: 2, pp.96 – 101
Kaboolian, L. (1998) “The New Public Management: Challenging the Boundaries of the Management vs. Administration Debate” Public Administration Review Vol. 58, No. 3 pp.189-193
Levi-Faur D. and Vigoda-Gadot Eran (eds) (2004) International Public Policy and Management: Policy Learning Beyond Regional, Cultural and Political Boundaries, Marcel Dekker,
Midgley, G. (ed) (2003) Systems Thinking. London: Sage Publications
Midgley, G. (2000) Systemic Intervention: Philosophy, Methodology and Practice. New York, NY: Kluwer.
Murtagh, B. (2002). The Politics of Territory: Policy and Segregation in Northern Ireland. Basingstoke, Palgrave.
Rhodes, ML, Joanne Murphy, Jenny Muir, John Murray (2011) Public Management & Complexity Theory: Richer Decision Making in Irish Public Services, UK: Routledge
Resumo:
Collagen is widely used as a biomedical material, and its importance is likely to grow as research and understanding progresses in this field. As a biomedical material, ensuring the sterility of collagen before use as, or incorporation into, a medical device is paramount. However, common sterilisation techniques can induce changes in the physical structure and protein chemistry of collagen, potentially affecting the performance. In this preliminary study, the influence of autoclaving, gamma irradiation and ethylene oxide gas sterilisation on the denaturation temperature and helical content of the collagen was evaluated using differential scanning calorimetry and Fourier transform infrared spectroscopy. Early results indicate that all sterilisation techniques affect collagen properties but suggest that the least damaging of the techniques investigated was y irradiation.
Resumo:
The aim of this study was to examine the potential of incorporating bovine fibres as a means of reinforcing a typically brittle apatite calcium phosphate cement for vertebroplasty. Type I collagen derived from bovine Achilles tendon was ground cryogenically to produce an average fibre length of 0.96 ± 0.55 mm and manually mixed into the powder phase of an apatite-based cement at 1, 3 or 5 wt.%. Fibre addition of up to 5 wt.% had a significant effect (P = 0.001) on the fracture toughness, which was increased by 172%. Adding =1 wt.% bovine collagen fibres did not compromise the compressive properties significantly, however, a decrease of 39-53% was demonstrated at =3 wt.% fibre loading. Adding bovine collagen to the calcium phosphate cement reduced the initial and final setting times to satisfy the clinical requirements stated for vertebroplasty. The cement viscosity increased in a linear manner (R = 0.975) with increased loading of collagen fibres, such that the injectability was found to be reduced by 83% at 5 wt.% collagen loading. This study suggests for the first time the potential application of a collagen-reinforced calcium phosphate cement as a viable option in the treatment of vertebral fractures, however, issues surrounding efficacious cement delivery need to be addressed. © 2012 Acta Materialia Inc.
Resumo:
The study aim was to develop and apply an experimental technique to determine the biomechanical effect of polymethylmethacrylate (PMMA) and calcium phosphate (CaP) cement on the stiffness and strength of augmented vertebrae following traumatic fracture. Twelve burst type fractures were generated in porcine three-vertebra segments. The specimens were randomly split into two groups (n=6), imaged using microCT and tested under axial loading. The two groups of fractured specimens underwent a vertebroplasty procedure, one group was augmented with CaP cement designed and developed at Queen's University Belfast. The other group was augmented with PMMA cement (WHW Plastics, Hull, UK). The specimens were imaged and re-tested . An intact single vertebra specimen group (n=12) was also imaged and tested under axial loading. A significant decrease (p<0.01) was found between the stiffness of the fractured and intact groups, demonstrating that the fractures generated were sufficiently severe, to adversely affect mechanical behaviour. Significant increase (p<0.01) in failure load was found for the specimen group augmented with the PMMA cement compared to the pre-augmentation group, conversely, no significant increase (p<0.01) was found in the failure load of the specimens augmented with CaP cement, this is attributed to the significantly (p<0.05) lower volume of CaP cement that was successfully injected into the fracture, compared to the PMMA cement. The effect of the percentage of cement fracture fill, cement modulus on the specimen stiffness and ultimate failure load could be investigated further by using the methods developed within this study to test a more injectable CaP cement.
Resumo:
Age-related macular degeneration (AMD) is a common cause of blindness in older individuals. To accelerate the understanding of AMD biology and help design new therapies, we executed a collaborative genome-wide association study, including >17,100 advanced AMD cases and >60,000 controls of European and Asian ancestry. We identified 19 loci associated at P <5 × 10(-8). These loci show enrichment for genes involved in the regulation of complement activity, lipid metabolism, extracellular matrix remodeling and angiogenesis. Our results include seven loci with associations reaching P <5 × 10(-8) for the first time, near the genes COL8A1-FILIP1L, IER3-DDR1, SLC16A8, TGFBR1, RAD51B, ADAMTS9 and B3GALTL. A genetic risk score combining SNP genotypes from all loci showed similar ability to distinguish cases and controls in all samples examined. Our findings provide new directions for biological, genetic and therapeutic studies of AMD.