217 resultados para Fire intensity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that for collisions of electrons with a high-intensity laser, discrete photon emissions introduce a transverse beam spread that is distinct from that due to classical (or beam shape) effects. Via numerical simulations, we show that this quantum induced transverse momentum gain of the electron is manifest in collisions with a realistic laser pulse of intensity within reach of current technology, and we propose it as a measurable signature of strong-field quantum electrodynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter focuses on the question of how to explain agency in the context of motherhood. In so doing, it seeks to go beyond the tendency to focus exclusively on the burden of coordination which institutional structures generate for mothers, in order to examine the evaluative burden which normative structures demand of this role. Drawing on interview material with 40 middle class mothers across two research sites in the UK and US, the paper develops a three-part typology of maternal role performance. This relies on the insights of contemporary action theory, with its emphasis on emotionally configured intersubjective interpretation of normative structures, and more specifically on Joas’s pragmatist theorisation of social action as a creative process. The paper argues that maternal agency takes three distinct ideal-typical forms, namely romantic expressivism, rational instrumentalism, and pragmatism. These are conceived as distinct creative responses to the evaluative demands of motherhood, as the agents go about interpreting situated norms, needs and interests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interaction of high‐intensity laser pulses with matter releases instantaneously ultra‐large currents of highly energetic electrons, leading to the generation of highly‐transient, large‐amplitude electric and magnetic fields. We report results of recent experiment in which such charge dynamics have been studied by using proton probing techniques able to provide maps of the electrostatic fields with high spatial and temporal resolution. The dynamics of ponderomotive channelling in underdense plasmas have been studied in this way, as also the processes of Debye sheath formation and MeV ion front expansion at the rear of laser‐irradiated thin metallic foils. An application employing laser‐driven impulsive fields for energy‐selective ion beam focusing is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives Stress control (SC), a brief psycho-education course, was implemented to increase access to psychological therapies in line with Northern Irish mental health service statutory drivers. The first aim of this study was to gauge the efficacy of SC in a robust manner with clinical significance testing. The second aim was to assess whether demographics traditionally ‘hard-to-reach’ – males, younger adults and those from deprived areas – accessed SC. The third aim was to elucidate what prompted their access and the experiences of attendees at SC. Methods Attendees at SC were 170 adults over six iterations of the course. Pre- and post-questionnaires included the Depression Anxiety Stress Scales – 21, captured demographic details and qualitative feedback, which was subject to a mixed-methods analysis. Results SC attendees reported significant decreases on depression, anxiety and stress sub-scales post-intervention. Moreover, 38.71% ( n =36) of attendees who completed SC exhibited clinically significant improvement afterwards on one or more sub-scale. Attendance figures for males, younger adults and those classified as socioeconomically deprived were modest. Patterns within the data suggested prospective success for targeting these cohorts. Conclusions SC attracted people in need of mental healthcare input and affected quantifiable change within those people’s lives, while satisfying statutory demands for service delivery in an accessible community context. Recommendations to increase engagement with those traditionally ‘hard-to-reach’ for psychological services are provided, which, if implemented, have the potential to achieve further compliance with Northern Irish mental health statutory drivers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The line intensity ratio method provides a nonintrusive diagnostic for the measurement of electron temperature in microwave-generated plasmas. For optically thin plasmas of low density, a line intensity method using He I lines can often be used, and is based on the fact that the electron impact excitation rate coefficients for helium singlet and triplet states are insensitive to electron density but differ as a function of the electron temperature. Line intensity measurements are presented from microwave-generated helium plasmas. Both steady-state corona and collision-radiative theoretical models are used to evaluate the ground and excited state populations. The line ratio versus electron temperature obtained from both of these methods are compared with the results from measurements. However, it is not possible to diagnose the electron temperature from the line ratios alone due to the presence of significant opacity and nonnegligible 1s2s S-3 metastable fraction in the plasma. (C) 2004 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The majority of stage III patients with non-small cell lung cancer (NSCLC) are unsuitable for concurrent chemoradiotherapy, the non-surgical gold standard of care. As the alternative treatment options of sequential chemoradiotherapy and radiotherapy alone are associated with high local failure rates, various intensification strategies have been employed. There is evidence to suggest that altered fractionation using hyperfractionation, acceleration, dose escalation, and individualisation may be of benefit. The MAASTRO group have pioneered the concept of ‘isotoxic’ radiotherapy allowing for individualised dose escalation using hyperfractionated accelerated radiotherapy based on predefined normal tissue constraints. This study aims to evaluate whether delivering isotoxic radiotherapy using intensity modulated radiotherapy (IMRT) is achievable.

Methods and analysis Isotoxic IMRT is a multicentre feasibility study. From June 2014, a total of 35 patients from 7 UK centres, with a proven histological or cytological diagnosis of inoperable NSCLC, unsuitable for concurrent chemoradiotherapy will be recruited. A minimum of 2 cycles of induction chemotherapy is mandated before starting isotoxic radiotherapy. The dose of radiation will be increased until one or more of the organs at risk tolerance or the maximum dose of 79.2 Gy is reached. The primary end point is feasibility, with accrual rates, local control and overall survival our secondary end points. Patients will be followed up for 5 years.

Ethics and dissemination The study has received ethical approval (REC reference: 13/NW/0480) from the National Research Ethics Service (NRES) Committee North West—Greater Manchester South. The trial is conducted in accordance with the Declaration of Helsinki and Good Clinical Practice (GCP). The trial results will be published in a peer-reviewed journal and presented internationally.

Trial registration number NCT01836692; Pre-results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Assess efficacy and acceptability of reduced intensity constraint-induced movement therapy (CIMT) in children with cerebral palsy (CP).

METHODS: Single-subject research design and semi-structured interviews. Children (9-11y) with hemiplegia underwent five baseline assessments followed by two weeks CIMT. Six further assessments were performed during treatment and follow-up phases. The primary outcome was the Melbourne Assessment of Unilateral Upper Limb Function (MUUL). Quantitative data were analysed using standard single-subject methods and qualitative data by thematic analysis.

RESULTS: Four of the seven participants demonstrated statistically significant improvements in MUUL (3-11%, p < .05). Two participants achieved significant improvements in active range of motion but strength and tone remained largely unchanged. Qualitative interviews highlighted limitations of the restraint, importance of family involvement, and coordination of treatment with education.

CONCLUSIONS: Reduced intensity CIMT may be effective for some children in this population; however it is not suitable for all children with hemiplegia.