218 resultados para Capture Enzyme-immunoassay
Resumo:
Neutrophil elastase (NE), a biomarker of infection and inflammation, correlates with the severity of several respiratory diseases including chronic obstructive pulmonary disease (COPD). However, it’s detection and quantification in biological samples is confounded by a lack of reliable and robust methodologies. Standard assays using chromogenic or fluorogenic substrates are not specific when added to complex clinical samples containing multiple proteolytic and hydrolytic enzymes which have the ability to hydrolyse the substrate, thereby resulting in an over-estimation of the target protease. Furthermore, ELISA systems measure total protease levels which can be a mixture of latent, active and protease-inhibitor complexes. Therefore, we have developed a novel immunoassay (ProteaseTag™ Active NE Immunoassay) which is selective and specific for the capture of active NE in sputum and Bronchoalveolar Lavage (BAL) in patients with COPD. The objective of this study was to clinically validate ProteaseTag™ Active NE Ultra Immunoassay for the detection of NE in sputum from COPD patients. 20 matched sputum sol samples were collected from 10 COPD patients (M=6, F=4; 73 ± 6 years) during stable and exacerbation phases. Samples were assayed for NE activity utilising both ProteaseTag™ Active NE Ultra Immunoassay and a fluorogenic substrate-based kinetic activity assay. Both assays detected elevated levels of NE in the majority of patients (n=7) during an exacerbation (mean=217.2 μg/ml ±296.6) compared to their stable phase (mean=92.37 μg/ml ±259.8). However, statistical analysis did not show this difference to be significant (p=0.07, ProteaseTag™ Active NE Ultra Immunoassay; p=0.06 kinetic assay), most likely due to the low study number. A highly significant correlation was found between the 2 assay types (p≤0.0001, r=0.996). NE as a primary efficacy endpoint in clinical trials or as a marker of inflammation within the clinic has been hampered by the lack of a robust and simple to use assay. ProteaseTag™ Active NE Immunoassay specifically measures only active NE in clinical samples, is quick and easy to use (< 3 hours) and has no dependency on a kinetic readout. ProteaseTag™ technology is currently being transferred to a lateral flow device for use at Point of Care.
Resumo:
Introduction: Neutrophil elastase (NE) is a serine protease implicated in the pathogenesis of several respiratory diseases including cystic fibrosis (CF). The presence of free NE in BAL is a predictor of subsequent bronchiectasis in children with CF (Sly et al, 2013, NEJM 368: 1963-1970). Furthermore, children with higher levels of sputum NE activity (NEa) tend to experience a more rapid decline in FEV1 over time even after adjusting for age, gender and baseline FEV1 (Sagel et al, 2012, AJRCCM 186: 857-865). Its detection and quantification in biological samples is however confounded by a lack of robust methodologies. Standard assays using chromogenic or fluorogenic substrates are not specific when added to complex samples containing multiple proteolytic and hydrolytic enzymes. ELISA systems measure total protein levels which can be a mixture of latent, active and protease-inhibitor complexes. We have therefore developed a novel assay (ProteaseTag™ Active NE Immunoassay), which couples an activity dependent NE-Tag with a specific antibody step, resulting in an assay which is both selective and specific for NEa. Aims: To clinically validate ProteaseTag™ Active NE for the detection of free NEa in BAL from children with CF. Methods: A total of 95 paediatric BAL samples [CF (n=76; 44M, 32F) non-CF (n=19; 12M, 7F)] collected through the Study of Host Immunity and Early Lung Disease in CF (SHIELD CF) were analysed for NEa using ProteaseTag™ Active NE (ProAxsis Ltd) and a fluorogenic substrate-based assay utilising Suc-AAPV-AMC (Sigma). IL-8 was measured by ELISA (R&D Systems). Results were analysed to show comparisons in free NEa between CF and non-CF samples alongside correlations with a range of clinical parameters. Results: NEa measured by ProteaseTag™ Active NE correlated significantly with age (r=0.3, p=0.01) and highly significantly with both IL-8 (r=0.4, p=<0.0001) and the absolute neutrophil count (ANC) (r=0.4, p=<0.0001). These correlations were not observed when NEa was measured by the substrate assay even though a significant correlation was found between the two assays (r=0.8, p<0.0001). A trend towards significance was found between NEa in the CF and non-CF groups when measured by ProteaseTag™ Active NE (p=0.07). Highly significant differences were found with the other inflammatory parameters between the 2 groups (IL-8: p=0.0002 and ANC: p=0.006). Conclusion: NEa as a primary efficacy endpoint in clinical trials or as a marker of inflammation within the clinic has been hampered by the lack of a robust and simple to use assay. ProteaseTag™ Active NE has been shown to be a specific and superior tool in the measurement of NEa in paediatric CF BAL samples (supporting data from previous studies using adult CF expectorated samples). The technology is currently being transferred to a lateral flow device for use at Point of Care. Acknowledgements: This work was supported by the National Children’s Research Centre, Dublin (SHIELD CF) and grants from the Medical Research Council and Cystic Fibrosis Foundation Therapeutics.
Resumo:
Introduction: Neuropeptides contribute to the pathophysiology of peripheral inflammation and a neurogenic component has been described for many inflammatory diseases, including periodontitis. Neuropeptides are susceptible to cleavage by peptidases and therefore the exact location and level of expression of peptidases are major determinants of neuropeptide action. Previous studies by our research group suggested that levels of the neuropeptide calcitonin gene-related peptide (CGRP) may be regulated by peptidases present in gingival crevicular fluid (GCF). Objectives: The aim of this work was to purify and partially characterize the GCF enzyme responsible for CGRP degradation using a biotinylated hydroxymate affinity probe (based on the P1-P4 amino acid sequence of the observed cleavage site) which we previously showed to inhibit CGRP degradation. Methods: Pooled healthy and pooled periodontitis GCF samples were subject to a pre-clear step with magnetic streptavadin beads. Healthy and diseased samples were incubated with the biotinylated hydroxymate probe (20 uM) after which biotinylated proteins were purified from the sample using magnetic streptavadin beads. Bound proteins were subjected to SDS-PAGE and western blotting. Biotin incorporated proteins were disclosed using a streptavadin horse radish peroxidase conjugate. Results: A band was disclosed in the periodontitis pooled sample at a molecular weight of approximately 60 kDa. The band was absent in the pooled healthy samples. As expected, when periodontitis samples were pre-boiled to denature proteins before the addition of the hydroxymate probe, no biotin incorporated band was present. Conclusions: This work demonstrates the purification and disclosure of a protein found specifically in periodontitis which binds to the specific biotinylated hydroxymate affinity probe based on the cleavage site of CGRP only when in its native form. We intend to scale up the sample size thus allowing the identification of the putative CGRP degrading peptidase using MALDI-mass spectrometry.
Funded by an IADR/GlaxoSmithKline Innovation in Oral Care Award
Resumo:
The miscibility of monoethanolamine (MEA) in five superbase ionic liquids (ILs), namely the trihexyl-tetradecylphosphonium benzotriazolide ([P66614][Bentriz]), trihexyl-tetradecylphosphonium benzimidazolide ([P66614][Benzim]), trihexyl-tetradecylphosphonium 1,2,3-triazolide ([P66614][123Triz]), trihexyl-tetradecylphosphonium 1,2,4-triazolide ([P66614][124Triz]), and trihexyl-tetradecylphosphonium imidazolide ([P66614][Im]) was determined at 295.15 K using 1H NMR spectroscopy. The solubility of carbon dioxide (CO2) in equimolar (IL + MEA) mixtures was then studied experimentally using a gravimetric technique at 295.15 K and 0.1 MPa. The effect of MEA on the CO2 capture ability of these ILs was investigated together with the viscosity of these systems in the presence or absence of CO2 to evaluate their practical application in CO2 capture processes. The effect of the presence of MEA on the rate of CO2 uptake was also studied. The study showed that the MEA can enhance CO2 absorption over the ideal values in the case of [P66614][123Triz] and [P66614][Bentriz] while in the other systems the mixtures behave ideally. A comparison of the effect of MEA addition with the addition of water to these superbase ILs showed that similar trends were observed in each case for the individual ILs studied.
Resumo:
ABSTRACT
The proliferation in the use of video lecture capture in universities worldwide presents an opportunity to analyse video watching patterns in an attempt to quantify and qualify how students engage and learn with the videos. It also presents an opportunity to investigate if there are similar student learning patterns during the equivalent physical lecture. The goal of this action based research project was to capture and quantitatively analyse the viewing behaviours and patterns of a series of video lecture captures across several university Java programming modules. It sought to study if a quantitative analysis of viewing behaviours of Lecture Capture videos coupled with a qualitative evaluation from the students and lecturers could be correlated to provide generalised patterns that could then be used to understand the learning experience of students during videos and potentially face to face lectures and, thereby, present opportunities to reflectively enhance lecturer performance and the students’ overall learning experience. The report establishes a baseline understanding of the analytics of videos of several commonly used pedagogical teaching methods used in the delivery of programming courses. It reflects on possible concurrences within live lecture delivery with the potential to inform and improve lecturing performance.
Resumo:
Biogas from anaerobic digestion of sewage sludge is a renewable resource with high energy content, which is formed mainly of CH4 (40-75 vol.%) and CO2 (15-60 vol.%) Other components such as water (H2O, 5-10 vol.%) and trace amounts of hydrogen sulfide and siloxanes can also be present. A CH4-rich stream can be produced by removing the CO2 and other impurities so that the upgraded bio-methane can be injected into the natural gas grid or used as a vehicle fuel. The main objective of this paper is to develop a new modeling methodology to assess the technical and economic performance of biogas upgrading processes using ionic liquids which physically absorb CO2. Three different ionic liquids, namely the 1-ethyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, 1-hexyl-3-methylimidazoliumbis[(trifluoromethyl)sulfonyl]imide and trihexyl(tetradecyl)phosphonium bis[(trifluoromethyl)sulfonyl]imide, are considered for CO2 capture in a pressure-swing regenerative absorption process. The simulation software Aspen Plus and Aspen Process Economic Analyzer is used to account for mass and energy balances as well as equipment cost. In all cases, the biogas upgrading plant consists of a multistage compressor for biogas compression, a packed absorption column for CO2 absorption, a flash evaporator for solvent regeneration, a centrifugal pump for solvent recirculation, a pre-absorber solvent cooler and a gas turbine for electricity recovery. The evaluated processes are compared in terms of energy efficiency, capital investment and bio-methane production costs. The overall plant efficiency ranges from 71-86 % whereas the bio-methane production cost ranges from £6.26-7.76 per GJ (LHV). A sensitivity analysis is also performed to determine how several technical and economic parameters affect the bio-methane production costs. The results of this study show that the simulation methodology developed can predict plant efficiencies and production costs of large scale CO2 capture processes using ionic liquids without having to rely on gas solubility experimental data.
Resumo:
Charge changing processes of MeV ions penetrating through liquid spray is confirmed to be abundant source of various energetic negative ion and neutral atom beams its generic nature is demonstrated.