441 resultados para B., A. P.
Resumo:
The IQGAP [IQ-motif-containing GAP (GTPase-activating protein)] family members are eukaryotic proteins that act at the interface between cellular signalling and the cytoskeleton. As such they collect numerous inputs from a variety of signalling pathways. A key binding partner is the calcium-sensing protein CaM (calmodulin). This protein binds mainly through a series of IQ-motifs which are located towards the middle of the primary sequence of the IQGAPs. In some IQGAPs, these motifs also provide binding sites for CaM-like proteins such as myosin essential light chain and S100B. Using synthetic peptides and native gel electrophoresis, the binding properties of the IQ-motifs from human IQGAP2 and IQGAP3 have been mapped. The second and third IQ-motifs in IQGAP2 and all four of the IQ-motifs of IQGAP3 interacted with CaM in the presence of calcium ions. However, there were differences in the type of interaction: while some IQ-motifs were able to form complexes with CaM which were stable under the conditions of the experiment, others formed more transient interactions. The first IQ-motifs from IQGAP2 and IQGAP3 formed transient interactions with CaM in the absence of calcium and the first motif from IQGAP3 formed a transient interaction with the myosin essential light chain MIc1sa. None of these IQ-motifs interacted with S100B. Molecular modelling suggested that all of the IQ-motifs, except the first one from IQGAP2 formed alpha-helices in solution. These results extend our knowledge of the selectivity of IQ-motifs for CaM and related proteins.
Resumo:
<p>The debate about the complex issues of human development during the Middle to Upper Palaeolithic transition period (45-35 ka BP) has been hampered by concerns about the reliability of the radiocarbon dating method. Large C-14 anomalies were postulated and radiocarbon dating was considered flawed. We show here that these issues are no longer relevant, because the large anomalies are artefacts beyond plausible physical limits for their magnitude. Previous inconsistencies between C-14 radiocarbon datasets have been resolved, and a new radiocarbon calibration curve, IntCal09 (Reimer et al., 2009), was created. Improved procedures for bone collagen extraction and charcoal pre-treatment generally result in older ages, consistent with independently dated time markers. (C) 2012 Elsevier Ltd. All rights reserved.p>
Resumo:
We present Gemini-N GMOS and CFHT MOS spectroscopy of Wolf-Rayet candidates in the Local Group dwarf galaxy IC 10 that were previously identified by Massey et al. and Royer et al. From the present spectroscopic survey, the WC/WN ratio for IC 10 remains unusually high, given its low metallicity, although none of the WC9 stars suspected from narrow-band imaging are confirmed. Our spectroscopy confirms 9 newly discovered Wolf-Rayet candidates from Royer et al., whilst spectral types of 14 Wolf-Rayet stars previously observed by Massey & Armandroff are refined here. In total, there are 26 spectroscopically confirmed Wolf-Rayet stars in IC 10. All but one of the fourteen WC stars are WC4-6 stars, the exception being # 10 from Massey et al., a broad-lined, apparently single WC7 star. There are a total of eleven WN stars, which are predominantly early WN3-4 stars, but include a rare WN10 star, # 8 from Royer et al. # 5 from Massey et al. is newly identified as a transition WN/C star. Consequently, the WC/WN ratio for IC10 is 14/11similar to1.3, unusually high for a metal-poor galaxy. Re-evaluating recent photometric data of Massey & Holmes, we suggest that the true WC/WN ratio may not be as low as similar to0.3. Finally, we present ground-based finding charts for all confirmed WR stars, plus HST/WFPC2 charts for twelve cases.
Resumo:
We have studied the effect of prepulses in enhancing the efficiency of generating ASE beams in soft X-ray laser plasma amplifiers based on pumping Ne-like ions, Slab targets were irradiated with a weak prepulse followed by a main plasma heating pulse of nanosecond duration, Time-integrated; time and spectrally resolved and time and angularly resolved lasing emissions on the 3p-3s (J=0-1) XUV lasing lines of Ne-like Ni, Cu and Zn at wavelengths 232 Angstrom 221 Angstrom and 212 Angstrom respectively have been monitored. Measurements were made for pre-pulse/main-pulse intensity ratios from 10(-5)-10(-1) and for pump delay times of 2 ns and 4.5 ns. Zinc is shown to exhibit a peak in output intensity at similar to 2x10(-3) pre-pulse fraction for a 4.5 ns pump delay, with a main pulse pump intensity of similar to 1.3x10(13) W cm(-2) on a 20 mm target. The Zn lasing emission had a duration of similar to 240 ps and this was insensitive to prepulse fraction. The J=0-1 XUV laser output for nickel and copper increased monotonically with prepulse fraction, with copper targets showing least sensitivity to either prepulse level or prepulse to main pulse delay. Under the conditions of the study, the pre-pulse level was observed to haveno significant influence on the output intensity of the 3p-3s (J=2-1) lines of any of the elements investigated.
Resumo:
Recent progress in the development of XUV lasers by research teams using high-power and ultrashort-pulse Nd:glass and KrF laser facilities at the Rutherford Appleton Laboratory is reviewed. Injector-amplifier operation and prepulse enhanced output of the Ge XXIII collisional laser driven by a kilojoule glass laser, enhanced gain in CVI recombination with picosecond CPA drive pulses from a glass laser, and optical field ionization and XUV harmonic generation with a KrF CPA laser are described.
Resumo:
We report a study of the effect of prepulses on XUV lasing of Ne-like germanium for an irradiation geometry where approximate to 20 mm long germanium slab targets were irradiated at approximate to 1.6 x 10(13) W cm(-2) using approximate to 0.7 ns (1.06 mu m) pulses from the VULCAN glass laser. Prepulses were generated at fractional power levels of approximate to 2 x 10(-4) (low) and approximate to 2 x 10(-2) (high) and arrived on target 5 and 3.2 ns respectively in advance of the main heating pulse, For both the low and high prepulses the output of the 3p-3s, J = 0-1, line at 19.6 nm was enhanced such that the peak radiant density (J/st) for this line became greater than that for the normally stronger J = 2-1 lines at 23.2 and 23.6 nm. The J = 0-1 line, whose FWHM duration was reduced from approximate to 450 ps to approximate to 100 ps, delivered approximate to 6 x more power (W) than the average for the combined J = 2-1 lines, whose FWHM duration was approximate to 500 ps for both levels of prepulse, The higher prepulse was more effective, yielding approximate to 2 x more radiant density and approximate to 7 x more power on both the J = 0-1 and J = 2-1 transitions compared to the low prepulse case, The most dramatic observation overall was the approximate to 40 x increase of power in the J = 0-1 line for the high prepulse (approximate to 2%) case compared with the zero prepulse case. These observations, coupled with measurements of beam divergence and beam deviation through refractive bending, as well as general agreement with modelling, lead us to conclude that, for germanium, the main influence of the prepulse is (a) to increase the energy absorbed from the main pulse, (b) to increase the volume of the gain zone and (c) to relax the plasma density gradients, particularly in the J = 0-1 gain zone.
Resumo:
Through the use of time-integrated space-resolved keV spectroscopy, we characterize line plasmas showing gain in Ne-like Zn with prepulsed irradiation to explain the enhanced performances of x-ray lasers using the prepulse technique. It is observed that the value of the electron temperature does not vary significantly with prepulse level, nor does its spatially resolved profile along the line. The lateral width and density of the Ne-like region in the plasma are seen to increase with the prepulse level. (C) 1995 Optical Society of America
Resumo:
The scaling of the flux and maximum energy of laser-driven sheath-accelerated protons has been investigated as a function of laser pulse energy in the range of 15-380 mJ at intensities of 10(16)-10(18) W/cm(2). The pulse duration and target thickness were fixed at 40 fs and 25 nm, respectively, while the laser focal spot size and drive energy were varied. Our results indicate that while the maximum proton energy is dependent on the laser energy and laser spot diameter, the proton flux is primarily related to the laser pulse energy under the conditions studied here. Our measurements show that increasing the laser energy by an order of magnitude results in a more than 500-fold increase in the observed proton flux. Whereas, an order of magnitude increase in the laser intensity generated by decreasing the laser focal spot size, at constant laser energy, gives rise to less than a tenfold increase in observed proton flux.