237 resultados para Defined Daily Dose


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of new treatments for older patients with acute myeloid leukemia is an active area, but has met with limited success. Vosaroxin, a quinolone-derived intercalating agent has several properties that could prove beneficial. Initial clinical studies showed it to be well-tolerated in older patients with relapsed/refractory disease. In vitro data suggested synergy with cytarabine (Ara-C). To evaluate vosaroxin, we performed 2 randomized comparisons within the "Pick a Winner" program. A total of 104 patients were randomized to vosaroxin vs low-dose Ara-C (LDAC) and 104 to vosaroxin + LDAC vs LDAC. When comparing vosaroxin with LDAC, neither response rate (complete recovery [CR]/complete recovery with incomplete count recovery [CRi], 26% vs 30%; odds ratio [OR], 1.16 (0.49-2.72); P = .7) nor 12-month survival (12% vs 31%; hazard ratio [HR], 1.94 [1.26-3.00]; P = .003) showed benefit for vosaroxin. Likewise, in the vosaroxin + LDAC vs LDAC comparison, neither response rate (CR/CRi, 38% vs 34%; OR, 0.83 [0.37-1.84]; P = .6) nor survival (33% vs 37%; HR, 1.30 [0.81-2.07]; P = .3) was improved. A major reason for this lack of benefit was excess early mortality in the vosaroxin + LDAC arm, most obviously in the second month following randomization. At its first interim analysis, the Data Monitoring and Ethics Committee recommended closure of the vosaroxin-containing trial arms because a clinically relevant benefit was unlikely.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here is detailed a novel and low-cost experimental method for high-throughput automated fluid sample irradiation. The sample is delivered via syringe pump to a nozzle, where it is expressed in the form of a hanging droplet into the path of a beam of ionising radiation. The dose delivery is controlled by an upstream lead shutter, which allows the beam to reach the droplet for a user defined period of time. The droplet is then further expressed after irradiation until it falls into one well of a standard microplate. The entire system is automated and can be operated remotely using software designed in-house, allowing for use in environments deemed unsafe for the user (synchrotron beamlines, for example). Depending on the number of wells in the microplate, several droplets can be irradiated before any human interaction is necessary, and the user may choose up to 10 samples per microplate using an array of identical syringe pumps, the design of which is described here. The nozzles consistently produce droplets of 25.1 ± 0.5 μl.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The proposed multi-table lookup architecture provides SDN-based, high-performance packet classification in an OpenFlow v1.1+ SDN switch. The objective of the demonstration is to show the functionality of the architecture deployed on the NetFPGA SUME Platform.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The proposition of increased innovation in network applications and reduced cost for network operators has won over the networking world to the vision of Software-Defined Networking (SDN). With the excitement of holistic visibility across the network and the ability to program network devices, developers have rushed to present a range of new SDN-compliant hardware, software and services. However, amidst this frenzy of activity, one key element has only recently entered the debate: Network Security. In this article, security in SDN is surveyed presenting both the research community and industry advances in this area. The challenges to securing the network from the persistent attacker are discussed and the holistic approach to the security architecture that is required for SDN is described. Future research directions that will be key to providing network security in SDN are identified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microneedles (MNs) are a minimally invasive drug delivery platform, designed to enhance transdermal drug delivery by breaching the stratum corneum. For the first time, this study describes the simultaneous delivery of a combination of three drugs using a dissolving polymeric MN system. In the present study, aspirin, lisinopril dihydrate, and atorvastatin calcium trihydrate were used as exemplar cardiovascular drugs and formulated into MN arrays using two biocompatible polymers, poly(vinylpyrrollidone) and poly(methylvinylether/maleic acid). Following fabrication, dissolution, mechanical testing, and determination of drug recovery from the MN arrays, in vitro drug delivery studies were undertaken, followed by HPLC analysis. All three drugs were successfully delivered in vitro across neonatal porcine skin, with similar permeation profiles achieved from both polymer formulations. An average of 126.3 ± 18.1 μg of atorvastatin calcium trihydrate was delivered, notably lower than the 687.9 ± 101.3 μg of lisinopril and 3924 ± 1011 μg of aspirin, because of the hydrophobic nature of the atorvastatin molecule and hence poor dissolution from the array. Polymer deposition into the skin may be an issue with repeat application of such a MN array, hence future work will consider more appropriate MN systems for continuous use, alongside tailoring delivery to less hydrophilic compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe formulation and evaluation of novel dissolving polymeric microneedle (MN) arrays for the facilitated delivery of low molecular weight, high dose drugs. Ibuprofen sodium was used as the model here and was successfully formulated at approximately 50% w/w in the dry state using the copolymer poly(methylvinylether/maleic acid). These MNs were robust and effectively penetrated skin in vitro, dissolving rapidly to deliver the incorporated drug. The delivery of 1.5mg ibuprofen sodium, the theoretical mass of ibuprofen sodium contained within the dry MN alone, was vastly exceeded, indicating extensive delivery of the drug loaded into the baseplates. Indeed in in vitro transdermal delivery studies, approximately 33mg (90%) of the drug initially loaded into the arrays was delivered over 24h. Iontophoresis produced no meaningful increase in delivery. Biocompatibility studies and in vivo rat skin tolerance experiments raised no concerns. The blood plasma ibuprofen sodium concentrations achieved in rats (263μgml(-1) at the 24h time point) were approximately 20 times greater than the human therapeutic plasma level. By simplistic extrapolation of average weights from rats to humans, a MN patch design of no greater than 10cm(2) could cautiously be estimated to deliver therapeutically-relevant concentrations of ibuprofen sodium in humans. This work, therefore, represents a significant progression in exploitation of MN for successful transdermal delivery of a much wider range of drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The purpose of this study was to verify clinical target volume-planning target volume (CTV-PTV) margins in single vocal cord irradiation (SVCI) of T1a larynx tumors and characterize inter- and intrafraction target motion.

METHODS AND MATERIALS: For 42 patients, a single vocal cord was irradiated using intensity modulated radiation therapy at a total dose of 58.1 Gy (16 fractions × 3.63 Gy). A daily cone beam computed tomography (CBCT) scan was performed to online correct the setup of the thyroid cartilage after patient positioning with in-room lasers (interfraction motion correction). To monitor intrafraction motion, CBCT scans were also acquired just after patient repositioning and after dose delivery. A mixed online-offline setup correction protocol ("O2 protocol") was designed to compensate for both inter- and intrafraction motion.

RESULTS: Observed interfraction, systematic (Σ), and random (σ) setup errors in left-right (LR), craniocaudal (CC), and anteroposterior (AP) directions were 0.9, 2.0, and 1.1 mm and 1.0, 1.6, and 1.0 mm, respectively. After correction of these errors, the following intrafraction movements derived from the CBCT acquired after dose delivery were: Σ = 0.4, 1.3, and 0.7 mm, and σ = 0.8, 1.4, and 0.8 mm. More than half of the patients showed a systematic non-zero intrafraction shift in target position, (ie, the mean intrafraction displacement over the treatment fractions was statistically significantly different from zero; P<.05). With the applied CTV-PTV margins (for most patients 3, 5, and 3 mm in LR, CC, and AP directions, respectively), the minimum CTV dose, estimated from the target displacements observed in the last CBCT, was at least 94% of the prescribed dose for all patients and more than 98% for most patients (37 of 42). The proposed O2 protocol could effectively reduce the systematic intrafraction errors observed after dose delivery to almost zero (Σ = 0.1, 0.2, 0.2 mm).

CONCLUSIONS: With adequate image guidance and CTV-PTV margins in LR, CC, and AP directions of 3, 5, and 3 mm, respectively, excellent target coverage in SVCI could be ensured.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present early photometric and spectroscopic observations of SN 2013ej, a bright Type IIP supernova (SN) in M74. SN 2013ej is one of the closest SNe ever discovered. The available archive images and the early discovery help to constrain the nature of its progenitor. The earliest detection of this explosion was on 2013 July 24.125 UT and our spectroscopic monitoring with the FLOYDS spectrographs began on July 27.7 UT, continuing almost daily for two weeks. Daily optical photometric monitoringwas achieved with the 1mtelescopes of the Las Cumbres Observatory Global Telescope (LCOGT) network, and was complemented by UV data from Swift and near-infrared spectra from Public ESO Spectroscopic Survey of Transient Objects and Infrared Telescope Facility. The data from our monitoring campaign show that SN 2013ej experienced a 10 d rise before entering into a well-defined plateau phase. This unusually long rise time for a Type IIP has been seen previously in SN 2006bp and SN 2009bw. A relatively rare strong absorption blueward of Hα is present since our earliest spectrum. We identify this feature as Si II, rather than high-velocity Hα as sometimes reported in the literature. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the effect of altering a single component of a rehabilitation programme (e.g. adding bilateral practice alone) on functional recovery after stroke, defined using a measure of activity.

DATA SOURCES: A search was conducted of Medline/Pubmed, CINAHL and Web of Science.

REVIEW METHODS: Two reviewers independently assessed eligibility. Randomized controlled trials were included if all participants received the same base intervention, and the experimental group experienced alteration of a single component of the training programme. This could be manipulation of an intrinsic component of training (e.g. intensity) or the addition of a discretionary component (e.g. augmented feedback). One reviewer extracted the data and another independently checked a subsample (20%). Quality was appraised according to the PEDro scale.

RESULTS: Thirty-six studies (n = 1724 participants) were included. These evaluated nine training components: mechanical degrees of freedom, intensity of practice, load, practice schedule, augmented feedback, bilateral movements, constraint of the unimpaired limb, mental practice and mirrored-visual feedback. Manipulation of the mechanical degrees of freedom of the trunk during reaching and the addition of mental practice during upper limb training were the only single components found to independently enhance recovery of function after stroke.

CONCLUSION: This review provides limited evidence to support the supposition that altering a single component of a rehabilitation programme realises greater functional recovery for stroke survivors. Further investigations are required to determine the most effective single components of rehabilitation programmes, and the combinations that may enhance functional recovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the increasing utilization of electric vehicles (EVs), transportation systems and electrical power systems are becoming increasingly coupled. However, the interaction between these two kinds of systems are not well captured, especially from the perspective of transportation systems. This paper studies the reliability of integrated transportation and electrical power system (ITES). A bidirectional EV charging control strategy is first demonstrated to model the interaction between the two systems. Thereafter, a simplified transportation system model is developed, whose high efficiency makes the reliability assessment of the ITES realizable with an acceptable accuracy. Novel transportation system reliability indices are then defined from the view point of EV’s driver. Based on the charging control model and the transportation simulation method, a daily periodic quasi sequential reliability assessment method is proposed for the ITES system. Case studies based on RBTS system demonstrate that bidirectional charging controls of EVs will benefit the reliability of power systems, while decrease the reliability of EVs travelling. Also, the optimal control strategy can be obtained based on the proposed method. Finally, case studies are performed based on a large scale test system to verify the practicability of the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-dose hyper-radiosensitivity (HRS) is the phenomenon whereby cells exposed to radiation doses of less than approximately 0.5 Gy exhibit increased cell killing relative to that predicted from back-extrapolating high-dose survival data using a linear-quadratic model. While the exact mechanism remains to be elucidated, the involvement of several molecular repair pathways has been documented. These processes in turn are also associated with the response of cells to O6-methylguanine (O6MeG) lesions. We propose a model in which the level of low-dose cell killing is determined by the efficiency of both pre-replicative repair by the DNA repair enzyme O6-methylguanine methyltransferase (MGMT) and post-replicative repair by the DNA mismatch repair (MMR) system. We therefore hypothesized that the response of cells to low doses of radiation is dependent on the expression status of MGMT and MMR proteins. MMR (MSH2, MSH6, MLH1, PMS1, PMS2) and MGMT protein expression signatures were determined in a panel of normal (PWR1E, RWPE1) and malignant (22RV1, DU145, PC3) prostate cell lines and correlated with clonogenic survival and cell cycle analysis. PC3 and RWPE1 cells (HRS positive) were associated with MGMT and MMR proficiency, whereas HRS negative cell lines lacked expression of at least one (MGMT or MMR) protein. MGMT inactivation had no significant effect on cell survival. These results indicate a possible role for MMR-dependent processing of damage produced by low doses of radiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Heparin therapy may be effective in steroid resistant inflammatory bowel disease.

AIM: A randomized pilot study, to compare unfractionated heparin as a first-line therapy with corticosteroids in colonic inflammatory bowel disease.

METHODS: Twenty patients with severe inflammatory bowel disease (ulcerative colitis, n=17; Crohn's colitis, n=3) were randomized to either intravenous heparin for 5 days, followed by subcutaneous heparin for 5 weeks (n=8), or high-dose intravenous hydrocortisone for 5 days followed by oral prednisolone 40 mg daily, reducing by 5 mg per day each week (n=12). After 5 days, non-responders in each treatment group were commenced on combination therapy. Response to therapy was monitored by: clinical disease activity (ulcerative colitis: Truelove and Witt Index; Crohn's colitis: Harvey and Bradshaw Index), stool frequency, serum C-reactive protein and alpha1 acid glycoprotein, endoscopic and histopathological grading.

RESULTS: The response rates were similar in both treatment groups: clinical activity index (heparin vs. steroid; 75% vs. 67%; P=0.23), stool frequency (75% vs. 67%; P=0.61), endoscopic (75% vs. 67%; P=0.4) and histopathological grading (63% vs. 50%; P=0.67). Both treatments were well-tolerated with no serious adverse events.

CONCLUSION: Heparin as a first line therapy is as effective as corticosteroids in the treatment of colonic inflammatory bowel disease. Large multicentre randomized comparative studies are required to determine the role of heparin in the management of inflammatory bowel disease.