199 resultados para Tests accuracy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polygenic risk scores have shown great promise in predicting complex disease risk and will become more accurate as training sample sizes increase. The standard approach for calculating risk scores involves linkage disequilibrium (LD)-based marker pruning and applying a p value threshold to association statistics, but this discards information and can reduce predictive accuracy. We introduce LDpred, a method that infers the posterior mean effect size of each marker by using a prior on effect sizes and LD information from an external reference panel. Theory and simulations show that LDpred outperforms the approach of pruning followed by thresholding, particularly at large sample sizes. Accordingly, predicted R(2) increased from 20.1% to 25.3% in a large schizophrenia dataset and from 9.8% to 12.0% in a large multiple sclerosis dataset. A similar relative improvement in accuracy was observed for three additional large disease datasets and for non-European schizophrenia samples. The advantage of LDpred over existing methods will grow as sample sizes increase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a spatio-temporal rich model of motion vector planes as a part of a full steganalytic system against motion vector based steganography. Superior detection accuracy of the rich model over the previous methods has been lately demonstrated for digital images in both spatial and DCT domain. It has not been heretofore used for detection of motion vector steganography. We also introduced a transformation so as to extend the feature set with temporal residuals. We carried out the tests along with most recent motion vector steganalysis and steganography methods. Test results show that the proposed model delivers an outstanding performance compared to the previous methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The properties of blood and the relative ease of access to which it can be retrieved make it an ideal source to gauge different aspects of homeostasis within an individual, form an accurate diagnosis, and formulate an appropriate treatment regime. Tests used to determine blood parameters such as the erythrocyte sedimentation rate, hemoglobin concentration, hematocrit, bleeding and clotting times, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, mean cell volume, and determination of blood groups are routinely used clinically, and deviations outside the normal range can indicate a range of conditions such as anemia, pregnancy, dehydration, overhydration, infectious disease, cancer, thyroid disease, and autoimmune conditions, to mention a few. As these tests can be performed relatively inexpensively and do not require high levels of technical expertise, they are ideally suited for use in the teaching laboratory, enabling undergraduate students to link theory to practice. The practicals described here permit students to examine their own blood and that of their peers and compare these with clinically accepted normal ranges. At the end of the practicals, students are required to answer a number of questions about their findings and to link abnormal values to possible pathological conditions by answering a series of questions based on their findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immunohistochemistry (IHC) is a widely available and highly utilised tool in diagnostic histopathology and is used to guide treatment options as well as provide prognostic information. IHC is subjected to qualitative and subjective assessment, which has been criticised for a lack of stringency, while PCR-based molecular diagnostic validations by comparison are regarded as very rigorous. It is essential that IHC tests are validated through evidence-based procedures. With the move to ISO15189 (2012), not just of the accuracy, specificity and reproducibility of each test need to be determined and managed, but also the degree of uncertainty and the delivery of such tests. The recent update to ISO 15189 (2012) states that it is appropriate to consider the potential uncertainty of measurement of the value obtained in the laboratory and how that may impact on prognostic or predictive thresholds. In order to highlight the problems surrounding IHC validity, we reviewed the measurement of Ki67and p53 in the literature. Both of these biomarkers have been incorporated into clinical care by pathology laboratories worldwide. The variation seen appears excessive even when measuring centrally stained slides from the same cases. We therefore propose in this paper to establish the basis on which IHC laboratories can bring the same level of robust validation seen in the molecular pathology laboratories and the principles applied to all routine IHC tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temperament tests are widely accepted as instruments for profiling behavioral variability in dogs, and they are applied in numerous areas of investigation (e.g. suitability for adoption or for breeding). During testing, to elicit a dog's reaction toward novel stimuli and predict its behavior in everyday life, model devices such as a child-like doll, or a fake dog, are often employed. However, the reliability of these devices to accurately stimulate dogs' reactions to children or dogs, is unknown and perhaps overestimated. This may be a particular concern in the case of aggressive behavior toward humans, a significant public health issue. The aim of this study was to: (1) evaluate the correlation between dogs' reactions to these devices, and owners' reports of their dog's aggression history (using the C-BARQ ??); (2) compare reactions toward the devices of dogs with and without histories of aggression. Subjects were selected among those visiting for behavioral consultation at the Veterinary Hospital of the University of Pennsylvania, and previously categorized as aggressive toward unfamiliar children, conspecifics, or as non-aggressive dogs (control). The test consisted of different components: an unfamiliar female tester approaching the dog; the presentation of a child-like doll, an ambiguous object, and a fake plastic dog. All tests were videotaped and durations of behaviors were later analyzed on the basis of a specified ethogram. Dogs' reactions were compared to C-BARQ scores, and interesting correlations emerged for 'dog-directed aggression/fear' (R = 0.48, P = 0.004), and 'stranger-directed aggression' (R = 0.58, P <0.001) factors. Dogs differed in their reactions toward the devices: the child-like doll and the fake dog elicited more social behaviors than the ambiguous object used as a control stimulus. Issues concerning the reliability of these tools to assess canine temperament are discussed. ?? 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. We assessed the prevalence and predictors of inaccurate refractive error among rural refractionists in western China. Methods. A subset of primary school children with visual acuity (VA) ≤6/12 in ≥1 eye, undergoing subjective refinement by local refractionists after cycloplegic autorefraction in an ongoing population-based study, received repeat refraction by university optometrists for quality control. Results. Among 502 children (mean age 10.5 years, 53.2% girls), independent predictors of poor (inaccurate by ≥1.0 diopter [D]) refraction by 21 rural practitioners (66.7% with high school or lower education) included hyperopia (odds ratio [OR], 4.2; 95% confidence interval [CI], 2.4-7.3, P < 0.001), astigmatism (OR = 3.8; 95% CI, 2.5-5.6; P < 0.001) and VA uncorrectable to >6/12 by the rural refractionist (OR = 4.7; 95% CI, 3.1-7.3; P = < 0.001). Among 201 children whose vision was uncorrectable in ≥1 eye by the rural refractionists, vision could be improved to >6/12 by the university optometrist in 110 (54.7%). We estimate vision could be so improved in 9.1% of all children refracted by these rural refractionists. A reason for inaccuracy in this setting is the erroneous tendency of rural refractionists to adjust instrument values for accommodation, even under cycloplegia. Conclusions. Rural refractionists in western China have little formal training and frequently fail to optimize VA among children, even when autorefractors are used. Training is needed emphasizing better use of automated refraction, particularly in children with astigmatism and hyperopia. © 2014 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess and improve the accuracy of lay screeners compared with vision professionals in detecting visual impairment in secondary schoolchildren in rural China. METHODS: After brief training, 32 teachers and a team of vision professionals independently measured vision in 1892 children in Xichang. The children also underwent vision measurement by health technicians in a concurrent government screening program. RESULTS: Of 32 teachers, 28 (87.5%) believed that teacher screening was worthwhile. Sensitivity (93.5%) and specificity (91.2%) of teachers detecting uncorrected presenting visual acuity of 20/40 or less were better than for presenting visual acuity (sensitivity, 85.2%; specificity, 84.8%). Failure of teachers to identify children owning but not wearing glasses and teacher bias toward better vision in children wearing glasses explain the worse results for initial vision. Wearing glasses was the student factor most strongly predictive of inaccurate teacher screening (P < .001). The sensitivity and specificity of the government screening program detecting low presenting visual acuity were 86.7% and 28.7%, respectively. CONCLUSIONS: Teacher vision screening after brief training can achieve accurate results in this setting, and there is support among teachers for screening. Screening of uncorrected rather than presenting visual acuity is recommended in settings with a high prevalence of corrected and uncorrected refractive error. Low specificity in the government program renders it ineffective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Primary angle-closure glaucoma (PACG) is a major cause of visual morbidity in East Asia. Dark-room provocative test (DRPT) has been used to determine which narrow angles have the risk to develop angle closure. However, the accuracy of DRPT might be altered because that after emerging from the dark room, the configuration of the angle is affected by the light of the slit-lamp and the appositionally closed angle reopens. The aim of this study was to examine the pupillary diameter in different light conditions and use it as a parameter to assess the accuracy of dark-room provocative test. METHODS: Patients with suspected primary angle-closure glaucoma undergoing DRPT were recruited. The anterior chamber angle was examined by anterior segment optical coherence tomography under the following conditions: (1) in standard room illumination; (2) after short-term dark-adaptation and (3) after DRPT. Mean values of pupil size and numbers of appositionally closed angle under different conditions were compared. RESULTS: A total of 47 eyes of 47 patients were analyzed. The pupil size after DRPT was smaller than that after short-term dark-adaptation (P < 0.001) and smaller than that in standard room illumination (P = 0.026). The numbers of appositionally closed angles after short-term dark-adaptation were significantly larger than those after DRPT (P < 0.001). There was no significant difference between the numbers of appositionally closed angles in standard room illumination and after DRPT (P = 0.157). CONCLUSIONS: Constriction of pupil size immediately after prolonged dark room provocative test may lead to change in the angle configuration, which may lead to false negative results. We suggest a modified protocol of recording intraocular pressure immediately after DRPT and performing gonioscopy following short-term dark adaptation to improve the accuracy of angle closure assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the sensitivity and specificity of models predicting myopia onset among ethnically Chinese children. METHODS: Visual acuity, height, weight, biometry (A-scan, keratometry), and refractive error were assessed at baseline and 3 years later using the same equipment and protocol in primary schools in Xiamen (China) and Singapore. A regression model predicting the onset of myopia < -0.75 diopters (D) after 3 years in either eye among Xiamen children was validated with Singapore data. RESULTS: Baseline data were collected from 236 Xiamen children (mean age, 7.82 ± 0.63 years) and from 1979 predominantly Chinese children in Singapore (7.83 ± 0.84 years). Singapore children were significantly taller and heavier, and had more myopia (31.4% vs. 6.36% < -0.75 D in either eye, P < 0.001) and longer mean axial length. Three-year follow-up was available for 80.0% of Xiamen children and 83.1% in Singapore. For Xiamen, the area under the receiver-operator curve (AUC) in a model including ocular biometry, height, weight, and presenting visual acuity was 0.974 (95% confidence interval [CI], 0.945-0.997). In Singapore, the same model achieved sensitivity, specificity, and positive predictive value of 0.844, 0.650, and 0.669, with an AUC of 0.815 (95% CI, 0.791-0.839). CONCLUSIONS: Accuracy in predicting myopia onset based on simple measurements may be sufficient to make targeted early intervention practical in settings such as Singapore with high myopia prevalence. Models based on cohorts with a greater prevalence of high myopia than that in Xiamen could be used to assess accuracy of models predicting more severe forms of myopia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE:

To assess the noneconomic value of tests used in the diagnosis and management of glaucoma, and explore the contexts and factors that determine such value.

DESIGN:

Perspective.

METHODS:

Selected articles from primary and secondary sources were reviewed and interpreted in the context of the authors' clinical and research experience, influenced by our perspectives on the tasks of reducing the global problem of irreversible blindness caused by glaucoma. The value of any test used in glaucoma is addressed by 3 questions regarding: its contexts, its kind of value, and its implicit or explicit benefits.

RESULTS:

Tonometry, slit-lamp gonioscopy, and optic disc evaluation remain the foundation of clinic-based case finding, whether in areas of more or less abundant resources. In resource-poor areas, there is urgency in identifying patients at risk for severe functional loss of vision; screening strategies have proven ineffective, and efforts are hindered by the inadequate allocation of support. In resource-abundant areas, the wider spectrum of glaucoma is addressed, with emphasis on early detection of structural changes of little functional consequence; these are increasingly the focus of new and expensive technologies whose clinical value has not been established in longitudinal and population-based studies. These contrasting realities in part reflect differences among the value ascribed, often implicitly, to the tests used in glaucoma.

CONCLUSIONS:

The value of any test is determined by 3 aspects: its context of usage; its comparative worth and to whom its benefit accrues; and how we define historically what we are testing. These multiple factors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Roadside safety barriers designs are tested with passenger cars in Europe using standard EN1317 in which the impact angle for normal, high and very high containment level tests is 20°. In comparison to EN1317, the US standard MASH has higher impact angles for cars and pickups (25°) and different vehicle masses. Studies in Europe (RISER) and the US have shown values for the 90th percentile impact angle of 30°–34°. Thus, the limited evidence available suggests that the 20° angle applied in EN 1317 may be too low.
The first goal of this paper is to use the US NCHRP database (Project NCHRP 17–22) to assess the distribution of impact angle and collision speed in recent ROR accidents. Second, based on the findings of the statistical analysis and on analysis of impact angles and speeds in the literature, an LS-DYNA finite element analysis was carried out to evaluate the normal containment level of concrete barriers in non-standard collisions. The FE model was validated against a crash test of a portable concrete barrier carried out at the UK Transport Research Laboratory (TRL).
The accident data analysis for run-off road accidents indicates that a substantial proportion of accidents have an impact angle in excess of 20°. The baseline LS-DYNA model showed good comparison with experimental acceleration severity index (ASI) data and the parametric analysis indicates a very significant influence of impact angle on ASI. Accordingly, a review of European run-off road accidents and the configuration of EN 1317 should be performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An overview of research on the development of the hybrid test method is presented. The maturity of the hybrid test method is mapped in order to provide context to individual research in the overall development of the test method. In the pseudo dynamic (PsD) test method, the equations of motion are solved using a time stepping numerical integration technique with the inertia and damping being numerically modelled whilst restoring force is physically measured over an extended timescale. Developments in continuous PsD testing led to the real-time hybrid test method and geographically distributed hybrid tests. A key aspect to the efficiency of hybrid testing is the substructuring technique where the critical structural subassemblies that are fundamental to the overall response of the structure are physically tested whilst the remainder of the structure whose response can be more easily predicted is numerically modelled. Much of the early research focused on developing the accuracy and efficiency of the test method, whereas more recently the method has matured to a level where the test method is applied purely as a dynamic testing technique. Developments in numerical integration methods, substructuring, experimental error reduction, delay compensation and speed of testing have led to a test method now in use as full-scale real-time dynamic testing method that is reliable, accurate, efficient and cost effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and AimsTo compare endoscopy and pathology sizing in a large population-based series of colorectal adenomas and to evaluate the implications for patient stratification into surveillance colonoscopy.MethodsEndoscopy and pathology sizes available from intact adenomas removed at colonoscopies performed as part of the Northern Ireland Bowel Cancer Screening Programme, from 2010 to 2015, were included in this study. Chi-squared tests were applied to compare size categories in relation to clinicopathological parameters and colonoscopy surveillance strata according to current American Gastroenterology Association and British Society of Gastroenterology guidelines.ResultsA total of 2521 adenomas from 1467 individuals were included. There was a trend toward larger endoscopy than pathology sizing in 4 of the 5 study centers, but overall sizing concordance was good. Significantly greater clustering with sizing to the nearest 5 mm was evident in endoscopy versus pathology sizing (30% vs 19%, p<0.001), which may result in lower accuracy. Applying a 10-mm cut-off relevant to guidelines on risk stratification, 7.3% of all adenomas and 28.3% of those 8 to 12 mm in size had discordant endoscopy and pathology size categorization. Depending upon which guidelines are applied, 4.8% to 9.1% of individuals had differing risk stratification for surveillance recommendations, with the use of pathology sizing resulting in marginally fewer recommended surveillance colonoscopies.ConclusionsChoice of pathology or endoscopy approaches to determine adenoma size will potentially influence surveillance colonoscopy follow-up in 4.8% to 9.1% of individuals. Pathology sizing appears more accurate than endoscopy sizing, and preferential use of pathology size would result in a small, but clinically important, decreased burden on surveillance colonoscopy demand. Careful endoscopy sizing is required for adenomas removed piecemeal.