186 resultados para Sandwich beams


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The scenario of "electron-capture and -loss" was recently proposed for the formation of negative ion and neutral atom beams with MeV kinetic energies. However, it does not explain why the formation of negative ions in a liquid spray is much more efficient than with an isolated atom. The role of atomic excited states in the charge-exchange processes is considered, and it is shown that it cannot account for the observed phenomena. The processes are more complex than the single electron-capture and -loss approach. It is suggested that the shell effects in the electronic structure of the projectile ion and/or target atoms may influence the capture/loss probabilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spectrally-peaked proton beams of high charge (Ep ≈ 8 MeV, ΔE ≈ 4 MeV, N ≈ 50 nC ) have been observed from the interaction of an intense laser (>1019Wcm-2) with ultrathinCHfoils, as measured by spectrally-resolved full beam profiles. These beams are reproducibly generated for foil thicknesses 5-100 nm, and exhibit narrowing divergence with decreasing target thickness down to ≈8° for 5 nm. Simulations demonstrate that the narrow energy spread feature is a result of buffered acceleration of protons. The radiation pressure at the front of the target results in asymmetric sheath fields which permeate throughout the target, causing preferential forward acceleration. Due to their higher chargeto-mass ratio, the protons outrun a carbon plasma driven in the relativistic transparency regime.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

State-of-the-art high power lasers can exert immense pressure on thin foils which can be used to accelerate energetic ion beams efficiently at the laser plasma interface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the PTW 1000SRS array with Octavius 4D phantom was characterised for FF and FFF beams. MU linearity, field size, dose rate, dose per pulse (DPP) response and dynamic conformal arc treatment accuracy of the 1000SRS array were assessed for 6MV, 6FFF and 10FFF beams using a Varian TrueBeam STx linac. The measurements were compared with a pinpoint IC, microdiamond IC and EBT3 Gafchromic film. Measured dose profiles and FWHMs were compared with film measurements. Verification of FFF volumetric modulated arc therapy (VMAT) clinical plans were assessed using gamma analysis with 3%/3 mm and 2%/2 mm tolerances (10% threshold). To assess the effect of cross calibration dose rate, clinical plans with different dose rates were delivered and analysed. Output factors agreed with film measurements to within 4.5% for fields between 0.5 and 1 cm and within 2.7% for field sizes between 1.5 and 10 cm and were highly correlated with the microdiamond IC detector. Field sizes measured with the 1000SRS array were within 0.5 mm of film measurements. A drop in response of up to 1.8%, 2.4% and 5.2% for 6MV, 6FFF and 10FFF beams respectively was observed with increasing nominal dose rate. With an increase in DPP, a drop of up to 1.7%, 2.4% and 4.2% was observed in 6MV, 6FFF and 10FFF respectively. The differences in dose following dynamic conformal arc deliveries were less than 1% (all energies) from calculated. Delivered VMAT plans showed an average pass percentage of 99.5(±0.8)% and 98.4(±3.4)% with 2%/2 mm criteria for 6FFF and 10FFF respectively. A drop to 97.7(±2.2)% and 88.4(±9.6)% were observed for 6FFF and 10FFF respectively when plans were delivered at the minimum dose rate and calibrated at the maximum dose rate. Calibration using a beam with the average dose rate of the plan may be an efficient method to overcome the dose rate effects observed by the 1000SRS array.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Charge changing processes of MeV ions penetrating through liquid spray is confirmed to be abundant source of various energetic negative ion and neutral atom beams its generic nature is demonstrated.