186 resultados para Phase Type Distribution


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper results are presented for a simple yet highly sensitive transceiver for phase modulated RFID applications. This is an advance on other simple RFID readers which can only operate with amplitude shift keyed (ASK) signals. Simple circuitry is achieved by the use of a novel injection locked PLL configuration which replaces the standard superhet type architecture normally used. The transceiver is shown to operate with a number of phase modulation modes which have certain advantages relating to distance to target. The paper concludes with practical results obtained for the transceiver when operated within a backscatter RFID application. A unique advantage of this transceiver is its complete immunity to the problem of TX/RX isolation, allowing for long ranges, estimated to be in the region of 80m at 1 GHz, to be achieved even in the presence of a simple backscatter target.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to increase understanding of the mechanism and dominant drivers influencing phase separation during ram extrusion of calcium phosphate (CaP) paste for orthopaedic applications. The liquid content of extrudate was determined, and the flow of liquid and powder phases within the syringe barrel during extrusion were observed, subject to various extrusion parameters. Increasing the initial liquid-to-powder mass ratio, LPR, (0.4-0.45), plunger rate (5-20 mm/min), and tapering the barrel exit (45°-90°) significantly reduced the extent of phase separation. Phase separation values ranged from (6.22 ± 0.69 to 18.94 ± 0.69 %). However altering needle geometry had no significant effect on phase separation. From powder tracing and liquid content determination, static zones of powder and a non-uniform liquid distribution was observed within the barrel. Measurements of extrudate and paste LPR within the barrel indicated that extrudate LPR remained constant during extrusion, while LPR of paste within the barrel decreased steadily. These observations indicate the mechanism of phase separation was located within the syringe barrel. Therefore phase separation can be attributed to either; (1) the liquid being forced downstream by an increase in pore pressure as a result of powder consolidation due to the pressure exerted by the plunger or (2) the liquid being drawn from paste within the barrel, due to suction, driven by dilation of the solids matrix at the barrel exit. Differentiating between these two mechanisms is difficult; however results obtained suggest that suction is the dominant phase separation mechanism occurring during extrusion of CaP paste.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: In view of the increased rates of pre-eclampsia observed in diabetic pregnancy and the lack of ex vivo data on placental biomarkers of oxidative stress in T1 diabetic pregnancy, the aim of the current investigation was to examine placental antioxidant enzyme status and lipid peroxidation in pregnant women with type 1 diabetes. A further objective of the study was to investigate the putative impact of vitamin C and E supplementation on antioxidant enzyme activity and lipid peroxidation in type 1 diabetic placentae.

METHODS: The current study measured levels of antioxidant enzyme [glutathione peroxidase (Gpx), glutathione reductase (Gred), superoxide dismutase (SOD) and catalase] activity and degree of lipid peroxidation (aqueous phase hydroperoxides and 8-iso-prostaglandin F2α) in matched central and peripheral samples from placentae of DAPIT (n=57) participants. Levels of vitamin C and E were assessed in placentae and cord blood.

RESULTS: Peripheral placentae demonstrated significant increases in Gpx and Gred activities in pre-eclamptic in comparison to non-pre-eclamptic women. Vitamin C and E supplementation had no significant effect on cord blood or placental levels of these vitamins, nor on placental antioxidant enzyme activity or degree of lipid peroxidation in comparison to placebo-supplementation.

CONCLUSION: The finding that maternal supplementation with vitamin C/E does not augment cord or placental levels of these vitamins is likely to explain the lack of effect of such supplementation on placental indices including antioxidant enzymes or markers of lipid peroxidation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Our objective is to define differences in circulating lipoprotein subclasses between intensive vs. conventional management of Type 1 diabetes during the randomization phase of the Diabetes Control and Complications Trial (DCCT). Nuclear magnetic resonance-determined lipoprotein subclass profiles (NMR-LSP), which estimate molar subclass concentrations and mean particle diameters, were determined in 1,294 DCCT subjects after a median of five (interquartile range: four, six) years following randomization to intensive or conventional diabetes management. In cross-sectional analyses, we compared standard lipids and NMR-LSP between treatment groups. Standard total-, LDL- and HDL-cholesterol levels were similar between randomization groups, while triglyceride levels were lower in the intensively treated group. NMR-LSP showed that intensive therapy was associated with larger LDL diameter (20.7 vs. 20.6 nm, p=0.01) and lower levels of small LDL (median: 465 vs. 552 nmol/l, p=0.007), total IDL/LDL (mean: 1000 vs. 1053 nmol/l, p=0.01), and small HDL (mean: 17.3 vs. 18.6 μmol/l, p<0.0001), the latter accounting for reduced total HDL (mean: 33.8 vs. 34.8 μmol/l, p=0.01). In conclusion, intensive diabetes therapy was associated with potentially favorable changes in LDL and HDL subclasses in sera. Further research will determine whether these changes contribute to the beneficial effects of intensive diabetes management on vascular complications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: RAS is mutated (RASMT) in ~55% of mCRC, and phase III studies have shown that patients harbouring RAS mutations do not benefit from anti-EGFR MoAbs. In addition, ~50% of RAS Wild Type (RASWT) will not benefit from the addition of an EGFR MoAb to standard chemotherapy. Hence, novel treatment strategies are urgently needed for RASMT and > 50% of RASWT mCRC patients. c-MET is overexpressed in ~50-60%, amplified in ~2-3% and mutated in ~3-5% of mCRC. Recent preclinical studies have shown that c-MET is an important mediator of resistance to MEK inhibitors (i) in RASMT mCRC, and that combined MEKi/METi resulted in synergistic reduction in tumour growth in RASMT xenograft models (1). A number of recent studies have highlighted the role of c-MET in mediating primary/secondary resistance to anti-EGFR MoAbs in mCRC, suggesting that patient with RASWT tumours with aberrant c-MET (RASWT/c-MET+) may benefit from anti-c-MET targeted therapies (2). These preclinical data supported the further clinical evaluation of combined MEKi/METi treatment in RASMT and RASWT CRC patients with aberrant c-MET signalling (overexpression, amplification or mutation; RASWT/c-MET+). Methods: MErCuRIC1 is a phase I combination study of METi crizotinib with MEKi PD-0325901. The dose escalation phase, utilizing a rolling six design, recruits 12-24 patients with advanced solid tumours and aims to assess safety/toxicity of combination, recommended phase II (RPII) dose, pharmacokinetics (PK) and pharmacodynamics (PD) (pERK1/2 in PBMC and tumour; soluble c-MET). In the dose expansion phase an additional 30-42 RASMT and RASWT/c-MET mCRC patients with biopsiable disease will be treated at the RPII dose to further evaluate safety, PK, PD and treatment response. In the dose expansion phase additional biopsy and blood samples will be obtained to define mechanisms of response/resistance to crizotinib/PD-0325901 therapy. Enrolment into the dose escalation phase began in December 2014 with cohort 1 still ongoing. EudraCT registry number: 2014-000463-40. (1) Van Schaeybroeck S et al. Cell Reports 2014;7(6):1940-55; (2) Bardelli A et al. Cancer Discov 2013;3(6):658-73. Clinical trial information: 2014-000463-40.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A relatively simple, selective, precise and accurate high performance liquid chromatography (HPLC) method based on a reaction of phenylisothiocyanate (PITC) with glucosamine (GL) in alkaline media was developed and validated to determine glucosamine hydrochloride permeating through human skin in vitro. It is usually problematic to develop an accurate assay for chemicals traversing skin because the excellent barrier properties of the tissue ensure that only low amounts of the material pass through the membrane and skin components may leach out of the tissue to interfere with the analysis. In addition, in the case of glucosamine hydrochloride, chemical instability adds further complexity to assay development. The assay, utilising the PITC-GL reaction was refined by optimizing the reaction temperature, reaction time and PITC concentration. The reaction produces a phenylthiocarbamyl-glucosamine (PTC-GL) adduct which was separated on a reverse-phase (RP) column packed with 5 microm ODS (C18) Hypersil particles using a diode array detector (DAD) at 245 nm. The mobile phase was methanol-water-glacial acetic acid (10:89.96:0.04 v/v/v, pH 3.5) delivered to the column at 1 ml min-1 and the column temperature was maintained at 30 degrees C. Galactosamine hydrochloride (Gal-HCl) was used as an internal standard. Using a saturated aqueous solution of glucosamine hydrochloride, in vitro permeation studies were performed at 32+/-1 degrees C over 48 h using human epidermal membranes prepared by a heat separation method and mounted in Franz-type diffusion cells with a diffusional area 2.15+/-0.1 cm2. The optimum derivatisation reaction conditions for reaction temperature, reaction time and PITC concentration were found to be 80 degrees C, 30 min and 1% v/v, respectively. PTC-Gal and GL adducts eluted at 8.9 and 9.7 min, respectively. The detector response was found to be linear in the concentration range 0-1000 microg ml-1. The assay was robust with intra- and inter-day precisions (described as a percentage of relative standard deviation, %R.S.D.) <12. Intra- and inter-day accuracy (as a percentage of the relative error, %RE) was <or=-5.60 and <or=-8.00, respectively. Using this assay, it was found that GL-HCl permeates through human skin with a flux 1.497+/-0.42 microg cm-2 h-1, a permeability coefficient of 5.66+/-1.6x10(-6) cm h-1 and with a lag time of 10.9+/-4.6 h.