273 resultados para Endodontic infection diagnostic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the state of the art for high power laser systems increases from terawatt to petawatt level and beyond, a crucial parameter for routinely monitoring high intensity performance is laser spot size on a solid target during an intense interaction in the tight focus regime ( 10(19) Wcm(-2) is demonstrated experimentally and shown to provide the basis for an effective focus diagnostic. Importantly, this technique is also shown to allow in-situ diagnosis of focal spot quality achieved after reflection from a double plasma mirror setup for very intense high contrast interactions (> 10(20) Wcm(-2)) an important application for the field of high laser contrast interaction science.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proton imaging has become a common diagnostic technique for use in laser-plasma research experiments due to their ability to diagnose electric field effects and to resolve small density differences caused through shock effects. These interactions are highly dependent on the use of radiochromic film (RCF) as a detection system for the particle probe, and produces very high-resolution images. However, saturation effects, and in many cases, damage to the film limits the usefulness of this technique for high-flux particle probing. This paper outlines the use of a new technique using contact radiography of (p,n)-generated isotopes in activation samples to produce high dynamic range 2D images with high spatial resolution and extremely high dynamic range, whilst maintaining both energy resolution and absolute flux measurements. (C)007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a diagnostic of high-intensity laser interactions (> 10(19) W cm(-2)), the detection of radioactive isotopes is regularly used for the characterization of proton, neutron, ion, and photon beams. This involves sample removal from the interaction chamber and time consuming post shot analysis using NaI coincidence counting or Ge detectors. This letter describes the use of in situ detectors to measure laser-driven (p,n) reactions in Al-27 as an almost real-time diagnostic for proton acceleration. The produced Si-27 isotope decays with a 4.16 s half-life by the predominantly beta+ emission, producing a strong 511 keV annihilation peak. (c) 2006 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method of measuring the temperature of the fast electrons produced in ultraintense laser-plasma interactions is described by inducing photonuclear reactions, in particular (gamma,n) and (gamma,3n) reactions in tantalum. Analysis of the gamma rays emitted by the daughter nuclei of these reactions using a germanium counter enables a relatively straightforward near real-time temperature measurement to be made. This is especially important for high temperature plasmas where alternative diagnostic techniques are usually difficult and time consuming. This technique can be used while other experiments are being conducted. (C) 2002 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial desaturation as measured using pulse oximetry may not reflect cardiorespiratory disease; other possible causes, including certain drugs, should be sought. Within the literature, examples exist of dapsone-induced methaemoglobinaemia causing diagnostic confusion, particularly where respiratory disease is a feature. Few cases have been reported that demonstrate the potential of relatively low levels of methaemoglobinaemia to upset pulse oximetry readings. We describe three examples of dapsone-induced methaemoglobinaemia emphasising the potential for low-grade methaemoglobinaemia to cause diagnostic confusion. Widespread use of the pulse oximeter indicates this problem may occur more regularly, hence there is a need for increased awareness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Removal of the spleen presents a lifelong risk of infection, in particular the syndrome of overwhelming postsplenectomy sepsis. Streptococcus pneumoniae, Haemophilus influenzae and Neisseria meningitides are the most common organisms involved, but malaria, babesiosis and DF-2 also create a problem. Immunisation with pneumococcal vaccine, H. influenzae type b vaccine, influenza vaccine and, if in a high risk area, meningococcal vaccine is recommended. Lifelong phenoxymethylpenicillin 250mg twice daily is also advised, especially in high risk groups such as children and immunocompromised patients. If patients are unwilling to take medicine lifelong, or are unlikely to comply, an antibiotic supply should be made available at all times and administration should commence at the first sign of illness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser driven proton beams have been used to diagnose transient fields and density perturbations in laser produced plasmas. Grid deflectometry techniques have been applied to proton radiography to obtain precise measurements of proton beam angles caused by electromagnetic fields in laser produced plasmas. Application of proton radiography to laser driven implosions has demonstrated that density conditions in compressed media can be diagnosed with million electron volt protons. This data has shown that proton radiography can provide unique insight into transient electromagnetic fields in super critical density plasmas and provide a density perturbation diagnostics in compressed matter.

Relevância:

20.00% 20.00%

Publicador: