183 resultados para Chamber music.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To describe and evaluate a new method for measuring anterior chamber volume (ACV). DESIGN: Observational case series. METHODS: The authors measured ACV using the anterior chamber (AC) optical coherence tomographer (OCT) and applied image-processing software developed by them. Repeatability was evaluated. The ACV was measured in patient groups with normal ACs, shallow ACs, and deep ACs. The volume difference before and after laser peripheral iridotomy (LPI) was analyzed for the shallow and deep groups. RESULTS: Coefficients of repeatability for intraoperator, interoperator, and interimage measurements were 0.406%, 0.958%, and 0.851%, respectively. The limits of agreement for intraoperator and interoperator measurement were -0.911 microl to 1.343 microl and -7.875 microl to -2.463 microl, respectively. There were significant ACV differences in normal, shallow, and deep AC eyes (P < .001) and before and after LPI in shallow AC (P < .001) and deep AC (P = .008) eyes. CONCLUSIONS: The ACV values obtained by this method were repeatable and in accord with clinical observation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Music therapy during palliative and end-of-life care is well established and positive benefits for patients have been reported.
Aim: Assess the effectiveness of music therapy versus standard care alone or standard care in combination with other therapies for improving psychological, physiological and social outcomes among adult patients in any palliative care setting.
Data sources: In order to update an existing Cochrane systematic review, we searched MEDLINE, CINAHL, EMBASE, PsycINFO, CENTRAL, ClinicalTrials.gov register, and Current Controlled Trials register to identify randomised or quasi-randomised controlled trails published between 2009 and April 2015. Nine electronic music therapy journals were searched from 2009 until April 2015, along with reference lists and contact was made with key experts in music therapy. Only studies published in English were eligible for inclusion. Two reviewers independently screened titles, abstracts, assessed relevant studies for eligibility, extracted data and judged risk of bias for included studies. Disagreements were resolved through discussion with a third reviewer. Data were synthesised in Revman using the random effects model. Heterogeneity was assessed using l2.
Results: Three studies were included in the review. Findings suggest music therapy may be effective for helping to reduce pain in palliative care patients (standard mean deviation (SMD) = -0.42, 95% CI -0.68 to -0.17, P = 0.001).
Conclusions: Available evidence did not support the use of music therapy to improve overall quality-of-life in palliative care. While this review suggests music therapy may be effective for reducing pain, this is based on studies with a high risk of bias. Further high quality research is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the PTW 1000SRS array with Octavius 4D phantom was characterised for FF and FFF beams. MU linearity, field size, dose rate, dose per pulse (DPP) response and dynamic conformal arc treatment accuracy of the 1000SRS array were assessed for 6MV, 6FFF and 10FFF beams using a Varian TrueBeam STx linac. The measurements were compared with a pinpoint IC, microdiamond IC and EBT3 Gafchromic film. Measured dose profiles and FWHMs were compared with film measurements. Verification of FFF volumetric modulated arc therapy (VMAT) clinical plans were assessed using gamma analysis with 3%/3 mm and 2%/2 mm tolerances (10% threshold). To assess the effect of cross calibration dose rate, clinical plans with different dose rates were delivered and analysed. Output factors agreed with film measurements to within 4.5% for fields between 0.5 and 1 cm and within 2.7% for field sizes between 1.5 and 10 cm and were highly correlated with the microdiamond IC detector. Field sizes measured with the 1000SRS array were within 0.5 mm of film measurements. A drop in response of up to 1.8%, 2.4% and 5.2% for 6MV, 6FFF and 10FFF beams respectively was observed with increasing nominal dose rate. With an increase in DPP, a drop of up to 1.7%, 2.4% and 4.2% was observed in 6MV, 6FFF and 10FFF respectively. The differences in dose following dynamic conformal arc deliveries were less than 1% (all energies) from calculated. Delivered VMAT plans showed an average pass percentage of 99.5(±0.8)% and 98.4(±3.4)% with 2%/2 mm criteria for 6FFF and 10FFF respectively. A drop to 97.7(±2.2)% and 88.4(±9.6)% were observed for 6FFF and 10FFF respectively when plans were delivered at the minimum dose rate and calibrated at the maximum dose rate. Calibration using a beam with the average dose rate of the plan may be an efficient method to overcome the dose rate effects observed by the 1000SRS array.