226 resultados para screening instrument


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dye-sensitized solar cells have attracted intense research attention owing to their ease of fabrication, cost-effectiveness and high efficiency in converting solar energy. Noble platinum is generally used as catalytic counter electrode for redox mediators in electrolyte solution. Unfortunately, platinum is expensive and non-sustainable for long-term applications. Therefore, researchers are facing with the challenge of developing low-cost and earth-abundant alternatives. So far, rational screening of non-platinum counter electrodes has been hamstrung by the lack of understanding about the electrocatalytic process of redox mediators on various counter electrodes. Here, using first-principle quantum chemical calculations, we studied the electrocatalytic process of redox mediators and predicted electrocatalytic activity of potential semiconductor counter electrodes. On the basis of theoretical predictions, we successfully used rust (alpha-Fe2O3) as a new counter electrode catalyst, which demonstrates promising electrocatalytic activity towards triiodide reduction at a rate comparable to platinum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alice is a 65 year-old woman who was recalled for further investigations following a routine screening mammogram, which showed a 25 mm mass in her left breast. This case history will report on the further investigations and surgery required to manage this infiltrating ductal carcinoma. The histopathology report will be analysed to provide a rationale for future treatment with radiotherapy, and Alice's expected prognosis will be presented using the Nottingham Prognostic Index. Alice's psychological support needs will identified and the appropriate interventions will be discussed with a particular focus on Alice's history of depression. The supportive and educational role of the breast care nurse and the multidisciplinary team will be highlighted throughout the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the value of conducting a glaucoma screening randomized controlled trial in the UK.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is substantial international variation in human papillomavirus (HPV) prevalence; this study details the first report from Northern Ireland and additionally provides a systematic review and meta-analysis pooling the prevalence of high-risk (HR-HPV) subtypes among women with normal cytology in the UK and Ireland. Between February and December 2009, routine liquid based cytology (LBC) samples were collected for HPV detection (Roche Cobas® 4800 [PCR]) among unselected women attending for cervical cytology testing. Four electronic databases, including MEDLINE, were then searched from their inception till April 2011. A random effects meta-analysis was used to calculate a pooled HR-HPV prevalence and associated 95% confidence intervals (CI). 5,712 women, mean age 39 years (±SD 11.9 years; range 20-64 years), were included in the analysis, of which 5,068 (88.7%), 417 (7.3%) and 72 (1.3%) had normal, low, and high-grade cytological findings, respectively. Crude HR-HPV prevalence was 13.2% (95% CI, 12.7-13.7) among women with normal cytology and increased with cytological grade. In meta-analysis the pooled HR-HPV prevalence among those with normal cytology was 0.12 (95% CIs, 0.10-0.14; 21 studies) with the highest prevalence in younger women. HPV 16 and HPV 18 specific estimates were 0.03 (95% CI, 0.02-0.05) and 0.01 (95% CI, 0.01-0.02), respectively. The findings of this Northern Ireland study and meta-analysis verify the prevalent nature of HPV infection among younger women. Reporting of the type-specific prevalence of HPV infection is relevant for evaluating the impact of future HPV immunization initiatives, particularly against HR-HPV types other than HPV 16 and 18. J. Med. Virol. 85:295-308, 2013. © 2012 Wiley Periodicals, Inc. Copyright © 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obesity has consistently been linked to an increased risk of colorectal cancer, particularly among men. Whether body mass index (BMI) differentially influences the risk across the stages of colorectal cancer development remains unclear. We evaluated the associations of BMI with colorectal adenoma incidence, adenoma recurrence, and cancer in the context of a large screening trial, in which cases and controls had an equal chance for disease detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The safety of our food is an essential requirement of society. One well-recognised threat is that of chemical contamination of our food, where low-molecular-weight compounds such as biotoxins, drug residues and pesticides are present. Low-cost, rapid screening procedures are sought to discriminate the suspect samples from the population, thus selecting only these to be forwarded for confirmatory analysis. Many biosensor assays have been developed as screening tools in food contaminant analysis, but these tend to be electrochemical, fluorescence or surface plasmon resonance based. An alternative approach is the use of biolayer interferometry, which has become established in drug discovery and life science studies but is only now emerging as a potential tool in the analysis of food contaminants. A biolayer interferometry biosensor was assessed using domoic acid as a model compound. Instrument repeatability was tested by simultaneously producing six calibration curves showing replicate repeatability (n = 2) ranging from 0.1 to 6.5 % CV with individual concentration measurements (n = 12) ranging from 4.3 to 9.3 % CV, giving a calibration curve midpoint of 7.5 ng/ml (2.3 % CV (n = 6)). Reproducibility was assessed by producing three calibration curves on different days, giving a midpoint of 7.5 ng/ml (3.4 %CV (n = 3)). It was further shown, using assay development techniques, that the calibration curve midpoint could be adjusted from 10.4 to 1.9 ng/ml by varying assay parameters before the simultaneous construction of three calibration curves in matrix and buffer. Sensitivity of the assay compared favourably with previously published biosensor data for domoic acid. © 2013 Springer-Verlag Berlin Heidelberg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A lateral flow immunoassay (LFIA) has been developed and fully validated to detect the primary amnesic shellfish poisoning (ASP) toxin, domoic acid (DA). The performance characteristics of two versions of the test were investigated using spiked and naturally contaminated shellfish (mussels, scallops, oysters, clams, and cockles). The tests provide a qualitative result, to indicate the absence or presence of DA in extracts of shellfish tissues, at concentrations that are relevant to regulatory limits. The new rapid assay (LFIA version 2) was designed to overcome the performance limitations identified in the first version of the assay. The improved test uses an electronic reader to remove the subjective nature of the generated results, and the positive cut-off for screening of DA in shellfish was increased from 10 ppm (version 1) to 17.5 ppm (version 2). A simple extraction and test procedure was employed, which required minimal equipment and materials; results were available 15 min after sample preparation. Stability of the aqueous extracts at room temperature (22 C) at four time points (up to 245 min after extraction) and across a range of DA concentrations was 100.3±1.3% and 98.8±2.4% for pre- and post-buffered extracts, respectively. The assay can be used both within laboratory settings and in remote locations. The accuracy of the new assay, to indicate negative results at or below 10 ppm DA, and positive results at or above 17.5 ppm, was 99.5% (n=216 tests). Validation data were obtained from a 2-day, randomised, blind study consisting of multiple LFIA lots (n=3), readers (n=3) and operators (n=3), carrying out multiple extractions of mussel tissue (n=3) at each concentration (0, 10, 17.5, and 20 ppm). No matrix effects were observed on the performance of the assay with different species (mussels, scallops, oysters, clams, and cockles). There was no impact on accuracy or interference from other phycotoxins, glutamic acid or glutamine with various strip incubations (8, 10, and 12 min). The accuracy of the assay, using naturally contaminated samples to indicate negative results at or below 12.5 ppm and positive results at or above 17.5 ppm, was 100%. Variability between three LFIA lots across a range of DA concentrations, expressed as coefficient of variation (% CV), was 1.1±0.4% (n=2 days) based on quantitative readings from the electronic reader. During an 8 week stability study, accuracy of the method with test strips stored at various temperatures (6, 22, 37 and 50 C) was 100%. Validation for both versions included comparisons with results obtained using reference LC-UV methods. © 2013 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the significant burden of cervical cancer, Malaysia like many middle-income countries relies on opportunistic cervical screening as opposed to a more organized population-based program. The aim of this study was to ascertain the effectiveness of a worksite screening initiative upon Papanicolaou smear test (Pap test) uptake among educated working women in Malaysia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fundamental understanding of the activity in heterogeneous catalysis has long been the major subject in chemistry. This paper shows the development of a two-step model to understand this activity. Using the theory of chemical potential kinetics with Bronsted-Evans-Polanyi relations, the general adsorption energy window is determined from volcano curves, using which the best catalysts can be searched. Significant insights into the reasons for catalytic activity are obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inconsistencies surrounding the prevalence levels of depression in later life suggest that the measurement of depression in older people may be problematic. The current study aimed to map responses to a depressive symptom scale, the Mental Health Index-5 (MHI-5) which is part of the Short form 36 (SF-36, Ware et al., 1993) against the diagnostic screening items of the Composite International Diagnostic Instrument-Short Form (CIDI-SF, Kessler et al., 1998) to examine disagreement rates across age groups. The study examined data from a national random sample of 10,641 participants living in Ireland, 58.8% were female and 19% were over 65 (SLÁN, 2007). CIDI-SF depression screening endorsement was lower in older groups, whereas mean MHI-5 depressive symptoms showed less change across age groups. Results showed that the odds of MHI-5 endorsers aged 18–44 endorsing CIDI-SF screening questions were 5 times and 4.5 times (dysphoria and anhedonia, respectively) greater than the odds of people aged 75 or more endorsing these items. Findings suggest that although the risk of depressive disorder may decrease with age, complex diagnostic screening questions may exaggerate lower rates of depression among older people.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of mobile ions complicates the implementation of voltage-modulated scanning probe microscopy techniques such as Kelvin probe force microscopy (KPFM). Overcoming this technical hurdle, however, provides a unique opportunity to probe ion dynamics and electrochemical processes in liquid environments and the possibility to unravel the underlying mechanisms behind important processes at the solid–liquid interface, including adsorption, electron transfer and electrocatalysis. Here we describe the development and implementation of electrochemical force microscopy (EcFM) to probe local bias- and time-resolved ion dynamics and electrochemical processes at the solid–liquid interface. Using EcFM, we demonstrate contact potential difference measurements, consistent with the principles of open-loop KPFM operation. We also demonstrate that EcFM can be used to investigate charge screening mechanisms and electrochemical reactions in the probe–sample junction. We further establish EcFM as a force-based imaging mode, allowing visualization of the spatial variability of sample-dependent local electrochemical properties.