177 resultados para Near-isogenic
Resumo:
Purpose
To evaluate the impact of the position of an asymmetric multifocal near segment on visual quality.
Setting
Cathedral Eye Clinic, Belfast, United Kingdom.
Design
Retrospective comparative case series.
Methods
Data from consecutive patients who had bilateral implantation of the Lentis Mplus LS-312 multifocal intraocular lens were divided into 2 groups. One group received inferonasal near-segment placement and the other, superotemporal near-segment placement. A +3.00 diopter (D) reading addition (add) was used in all eyes. The main outcome measures included uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), contrast sensitivity, and quality of vision. Follow-up was 3 months.
Results
Patients ranged in age from 43 to 76 years. The inferonasal group comprised 80 eyes (40 patients) and the superotemporal group, 76 eyes (38 patients). The mean 3-month spherical equivalent was −0.11 D ± 0.49 (SD) in the inferonasal group and −0.18 ± 0.46 D in the superotemporal group. The mean postoperative UDVA was 0.14 ± 0.10 logMAR and 0.18 ± 0.15 logMAR, respectively. The mean monocular UNVA was 0.21 ± 0.14 logRAD and 0.24 ± 0.13 logRAD, respectively. No significant differences were observed in the higher-order aberrations, total Strehl ratio (point-spread function), or modulation transfer function between the groups. Dysphotopic symptoms measured with a validated quality-of-vision questionnaire were not significantly different between groups.
Conclusion
Positioning of the near add did not significantly affect objective or subjective visual function parameters.
Resumo:
A novel type of microwave probes based on the loaded aperture geometry has been proposed and experimentally evaluated for dielectrics characterisation and high-resolution near-field imaging. Experimental results demonstrate the possibility of very accurate microwave spectroscopic characterisation of thin lossy dielectric samples and biological materials containing water. High-resolution images of the subwavelength lossy dielectric strips and wet and dry leaves have been obtained with amplitude contrast around 10-20 dB and spatial resolution better than one-tenth of a wavelength in the near-field zone. A microwave imaging scenario for the early-stage skin cancer identification based on the artificial dielectric model has also been explored. This model study shows that the typical resolution of an artificial malignant tumour with a characteristic size of one-tenth of a wavelength can be discriminated with at least 6 dB amplitude and 50° phase contrast from the artificial healthy skin and with more than 3 dB contrast from a benign lesion of the same size. It has also been demonstrated that the proposed device can efficiently deliver microwave energy to very small, subwavelength, focal areas which is highly sought in the microwave hyperthermia applications.
Resumo:
A significant portion of UK’s infrastructures earthworks was built more than 100 years ago, without modern construction standards: poor maintenance and the change of precipitations pattern experienced in the past decades are currently compromising their stability, leading to an increasing number of failures. To address the need for a reliable and time-efficient monitoring of earthworks at risk of failure we propose here the use of two established seismic techniques for the characterization of the near surface, MASW and P-wave refraction. We have regularly collected MASW and P-wave refraction data, from March 2014 to February 2015, along 4 reduced-scale seismic lines located on the flanks of a heritage railway embankment located in Broadway, SW of England. We have observed a definite temporal variability in terms of phase velocities of SW dispersion curves and of P-wave travel times. The accurate choice of ad-hoc inversion strategies has allowed to reconstruct reliable VP and VS models through which it is potentially possible to track the temporal variations of geo-mechanical properties of the embankment slopes. The variability over time of seismic data and seismic velocities seems to correlate well with rainfall data recorded in the days immediately preceding the date of acquisition.
Resumo:
Purpose: To estimate the prevalence, potential determinants, and proportion of met need for near vision impairment (NVI) correctable with refraction approximately 2 years after initial examination of a multi-country cohort. Design: Population-based, prospective cohort study. Participants: People aged ≥35 years examined at baseline in semi-rural (Shunyi) and urban (Guangzhou) sites in China; rural sites in Nepal (Kaski), India (Madurai), and Niger (Dosso); a semi-urban site (Durban) in South Africa; and an urban site (Los Angeles) in the United States. Methods: Near visual acuity (NVA) with and without current near correction was measured at 40 cm using a logarithm of the minimum angle of resolution near vision tumbling E chart. Participants with uncorrected binocular NVA ≤20/40 were tested with plus sphere lenses to obtain best-corrected binocular NVA. Main Outcome Measures: Prevalence of total NVI (defined as uncorrected NVA ≤20/40) and NVI correctable and uncorrectable to >20/40, and current spectacle wearing among those with bilateral NVA ≤20/63 improving to >20/40 with near correction (met need). Results: Among 13 671 baseline participants, 10 533 (77.2%) attended the follow-up examination. The prevalence of correctable NVI increased with age from 35 to 50-60 years and then decreased at all sites. Multiple logistic regression modeling suggested that correctable NVI was not associated with gender at any site, whereas more educated persons aged >54 years were associated with a higher prevalence of correctable NVI in Nepal and India. Although near vision spectacles were provided free at baseline, wear among those who could benefit was <40% at all but 2 centers (Guangzhou and Los Angeles). Conclusions: Prevalence of correctable NVI is greatest among persons of working age, and rates of correction are low in many settings, suggesting that strategies targeting the workplace may be needed.
Resumo:
OBJECTIVE:
To study the associations between near work, outdoor activity, and myopia among children attending secondary school in rural China.
METHODS:
Among a random cluster sample of 1892 children in Xichang, China, subjects with an uncorrected acuity of 6/12 or less in either eye (n = 984) and a 25% sample of children with normal vision (n = 248) underwent measurement of refractive error. Subjects were administered a questionnaire on parental education, time spent outdoors, and weekly time spent engaged in and preferred working distance for a variety of near-work activities.
RESULTS:
Among 1232 children with refraction data, 998 (81.0%) completed the near-work survey. Their mean age was 14.6 years (SD, 0.8 years), 55.6% were girls, and 83.1% had myopia of -0.5 diopters or less (more myopia) in both eyes. Time and diopter-hours spent on near activities did not differ between children with and without myopia. In regression models, time spent on near activities and time outdoors were unassociated with myopia, adjusting for age, sex, and parental education.
CONCLUSIONS:
These and other recent results raise some doubts about the association between near work and myopia. Additional efforts to identify other environmental factors associated with myopia risk and that may be amenable to intervention are warranted.
Resumo:
PURPOSE: Presbyopia limits activities of daily living, but population-based data from rural China are scarce. METHODS: A population-based, cross-sectional study was conducted in 2009 among all persons aged 40+ years in a rural area near Shenyang, China. Distance and near VA were measured using logMAR E charts. Individuals with pinhole-corrected distance vision ≥20/63 underwent detailed eye examination and near refraction. RESULTS: A total of 1008 (91.5%) respondents were examined (mean age, 58.4 ± 10.7 years for men, 56.8 ± 9.89 years for women). Women and older subjects were more likely to participate. The prevalence of functional presbyopia (near vision <20/50 [N8] improved by ≥1 line with correction) was 67.3% (95% confidence interval [CI], 64.30%-70.09%), increasing from 27.6% at 40 to 49 years of age to 81.8% at 60 to 69 years. Multivariate analysis showed that older age (P < 0.001), but not gender or education, was significantly associated with a higher risk of presbyopia. Self-reported presbyopic spectacle correction coverage was 51.5%. In multivariate logistic regression models, worse presenting near vision (P = 0.013) and higher required spherical equivalent power (P < 0.001) were associated with having correction, while age, gender, education, and distance vision were unassociated. Major barriers reported by persons without near correction included poor quality of available glasses (33.1%) and lack of awareness of the condition and its treatment (28.8%). CONCLUSIONS: Presbyopia is highly prevalent in rural China, and nearly half of affected persons have no access to correction. Interventions should focus on education and improvement in the quality of refractive services.
Resumo:
PURPOSE: To evaluate the impact of near-vision impairment on visual functioning and quality of life in a rural adult population in Shenyang, northern China. METHODS: A population-based, cross-sectional study was conducted among persons aged 40+ years, during which functional presbyopia (correctable presenting near vision < 20/50 [N8] at 40 cm) was assessed. Near-vision-related quality of life and spectacle usage questionnaires were administered by trained interviewers to determine the degree of self-rated difficulty with near tasks. RESULTS: A total of 1008 respondents (91.5% of 1102 eligible persons) were examined, and 776 (78%) of completed the questionnaires (mean age, 57.0 ± 10.2 years; 63.3% women). Near-vision spectacle wearers obtained their spectacles primarily from markets (74.5%) and optical shops (21.7%), and only 1.14% from eye clinics. Among 538 (69.3%) persons with functional presbyopia, self-rated overall (distance and near) vision was worse (P < 0.001) and difficulty with activities of daily living greater (P < 0.001) than among nonpresbyopes. Odds of reporting any difficulty with daily tasks remained higher (OR = 2.32; P < 0.001) for presbyopes after adjustment for age, sex, education and distance vision. Compared to persons without presbyopia, presbyopic persons were more likely to report diminished accomplishment due to vision (P = 0.01, adjusted for age, sex, education, and distance vision.) CONCLUSIONS: Difficulties with activities of daily living and resulting social impediments are common due to presbyopia in this setting. Most spectacle wearers with presbyopia in rural China obtain near correction from sources that do not provide comprehensive vision care.
Resumo:
A novel microwave high-resolution near-field imaging technique is proposed and experimentally evaluated in reflectometry imaging scenarios involving planar metal-dielectric structures. Two types of resonance near field probes-a small helix antenna and a loaded subwavelength slot aperture are studied in this paper. These probes enable very tight spatial field localization with the full width at half maximum around one tenth of a wavelength, λ, at λ/100-λ/10 standoff distance. Importantly, the proposed probes permit resonance electromagnetic coupling to dielectric or printed conductive patterns, which leads to the possibility of very high raw image resolution with imaged feature-to-background contrast greater than 10-dB amplitude and 50° phase. In addition, high-resolution characterization of target geometries based on the cross correlation image processing technique is proposed and assessed using experimental data. It is shown that printed elements features with subwavelength size ~λ/15 or smaller can be characterized with at least 10-dB resolution contrast.
Resumo:
Resonance states in atoms or ions at low energies can control the rates of important plasma processes (e.g., dielectronic recombination). We examine the role of states at negative energies just below the ionization threshold of the recombined system and find that they can contribute as much, or more, to recombination as positive energy states. In plasmas, negative energy states can be populated by three body recombination, photorecombination, or continuum lowering. Properly including these negative energy states in a theoretical treatment of plasma processes can change the thermally averaged rate coefficients and, in some cases, removes much of the sensitivity to the energy of a state.
Resumo:
This is an essay including annotated critical editions documenting the history of reception of this song since 1848. Published in the Liederlexikon for the AHRC and DFG funded project 'The History of Reception of the Songs of the 1848 Revolution' (2009-2013).