237 resultados para Dental software
Resumo:
The agile model of software development has been mainstream for several years, and is now in a phase where its principles and practices are maturing. The purpose of this paper is to describe the results of an industry survey aimed at understanding how maturation is progressing. The survey was taken across 40 software development companies in Northern Ireland at the beginning of 2012. The paper describes the design of the survey and examines maturity by comparing the results obtained in 2012 with those from a study of agile adoption in the same region in 2010. Both surveys aimed to achieve comprehensive coverage of a single area rather than rely on a voluntary sample. The main outcome from the work is a collection of ‘insights’ into the nature and practice of agile development, the main two of which are reported in this paper.
Resumo:
Software is patentable in Europe so long as there is sufficient ‘technical contribution’ under the decades-long interpretation of the European Patent Convention made by the Boards of Appeal of the European Patent Office. Despite the failure of the proposed Directive on Computer Implemented Inventions, opponents of software patents have failed to have any affect upon this technical contrivance. Yet, while national courts find the Boards of Appeal decisions persuasive, ‘technical contribution’ remains a difficult test for these various courts to apply. In this article I outline that the test is difficult to utilise in national litigation (it is an engineering approach, rather than a legal one) and suggest that as the Boards of Appeal become less important (and thus less persuasive) should the proposed Unified Patent Court come to fruition, the ‘technical contribution’ test is unlikely to last. This may again make the whole issue of what/whether/how software should be patentable open to debate, hopefully in a less aggressive environment than has existed to date.
Resumo:
Endodontic lubricants, irrigating solutions and medicaments help reduce the microbial load within root canals. Primary and secondary cases involve different microbes. Each'solution'or combinations thereof could play a significant role but no detailed guidelines exist on their use. An audit was undertaken to compare current practice in Belfast Dental School to the others across the UK and Republic of Ireland (ROI). This audit highlighted three main differences between Belfast and other dental schools. Many other institutions utilized other irrigants besides sodium hypochlorite (NaOCl), different intracanal medicaments, including calcium hydroxide, and higher concentrations of NaOCl. Having gathered this information, we ask, 'Is there sufficient evidence to change the endodontic regime currently used at Belfast Dental School?'. Using the findings from the literature review (Part 1), we introduce new evidence-based protocols for primary and secondary cases for use in Belfast Dental School. Clinical Relevance: In the absence of detailed clinical guidelines on the use of endodontic lubricants, irrigants and medicaments in primary and secondary cases, it is important to be aware of current practice in UK and ROI dental schools where dentists and specialists are trained.
Resumo:
Objectives: To investigate dental erosion among 12-14 year old Sudanese school children and evaluate the associated risk factors. Basic Research Design: Cross sectional survey in secondary schools in Khartoum city, Sudan. Method and Participants: A sample of 157 school children was obtained from both private and public schools. Erosion on the labial and palatal surfaces of maxillary incisors was measured by criterion based on the Smith and Knight Tooth Wear Index. Dietary intake and other related factors were assessed using a questionnaire. Results: The overall erosion prevalence in this group was 66.9%, of which 45.2% was mild and 21.7% was moderate erosion. A strong association was found between erosion and private schooling (higher socioeconomic groups), carbonated drinks, herbal hibiscus drink and traditional acidic food consumption. Conclusion: There was a high prevalence of dental erosion among Sudanese school children which was mild to moderate in severity and was strongly associated with acidic dietary intake © BASCD 2007.
Resumo:
Abstract
INTRODUCTION:
Transient receptor potential (TRP) channels comprise a group of nonselective calcium-permeable cationic channels, which are polymodal sensors of environmental stimuli such as thermal changes and chemicals. TRPM8 and TRPA1 are cold-sensing TRP channels activated by moderate cooling and noxious cold temperatures, respectively. Both receptors have been identified in trigeminal ganglion neurones, and their expression in nonneuronal cells is now the focus of much interest. The aim of this study was to investigate the molecular and functional expression of TRPA1 and TRPM8 in dental pulp fibroblasts.
METHODS:
Human dental pulp fibroblasts were derived from healthy molar teeth. Gene and protein expression was determined by polymerase chain reaction and Western blotting. Cellular localization was investigated by immunohistochemistry, and TRP functionality was determined by Ca(2+) microfluorimetry.
RESULTS:
Polymerase chain reaction and Western blotting showed gene and protein expression of both TRPA1 and TRPM8 in fibroblast cells in culture. Immunohistochemistry studies showed that TRPA1 and TRPM8 immunoreactivity co-localized with the human fibroblast surface protein. In Ca(2+) microfluorimetry studies designed to determine the functionality of TRPA1 and TRPM8 in pulp fibroblasts, we showed increased intracellular calcium ([Ca(2+)](i)) in response to the TRPM8 agonist menthol, the TRPA1 agonist cinnamaldehyde, and to cool and noxious cold stimuli, respectively. The responses to agonists and thermal stimuli were blocked in the presence of specific TRPA1 and TRPM8 antagonists.
CONCLUSIONS:
Human dental pulp fibroblasts express TRPA1 and TRPM8 at the molecular, protein, and functional levels, indicating a possible role for fibroblasts in mediating cold responses in human teeth.
Resumo:
The effect of preparation design and the physical properties of the interface lute on the restored machined ceramic crown-tooth complex are poorly understood. The aim of this work was to determine, by means of three-dimensional finite element analysis (3D FEA) the effect of the tooth preparation design and the elastic modulus of the cement on the stress state of the cemented machined ceramic crown-tooth complex. The three-dimensional structure of human premolar teeth, restored with adhesively cemented machined ceramic crowns, was digitized with a micro-CT scanner. An accurate, high resolution, digital replica model of a restored tooth was created. Two preparation designs, with different occlusal morphologies, were modeled with cements of 3 different elastic moduli. Interactive medical image processing software (mimics and professional CAD modeling software) was used to create sophisticated digital models that included the supporting structures; periodontal ligament and alveolar bone. The generated models were imported into an FEA software program (hypermesh version 10.0, Altair Engineering Inc.) with all degrees of freedom constrained at the outer surface of the supporting cortical bone of the crown-tooth complex. Five different elastic moduli values were given to the adhesive cement interface 1.8 GPa, 4 GPa, 8 GPa, 18.3 GPa and 40 GPa; the four lower values are representative of currently used cementing lutes and 40 GPa is set as an extreme high value. The stress distribution under simulated applied loads was determined. The preparation design demonstrated an effect on the stress state of the restored tooth system. The cement elastic modulus affected the stress state in the cement and dentin structures but not in the crown, the pulp, the periodontal ligament or the cancellous and cortical bone. The results of this study suggest that both the choice of the preparation design and the cement elastic modulus can affect the stress state within the restored crown-tooth complex.
Resumo:
Objective: The aim of this research is to use finite element analysis (FEA) to quantify the effect of the sample shape and the imperfections induced during the manufacturing process of samples on the bond strength and modes of failure of dental adhesive systems through microtensile test. Using the FEA prediction for individual parameters effect, estimation of expected variation and spread of the microtensile bond strength results for different sample geometries is made. Methods: The estimated stress distributions for three different sample shapes, hourglass, stick and dumbbell predicted by FEA are used to predict the strength for different fracture modes. Parameters such as the adhesive thickness, uneven interface of the adhesive and composite and dentin, misalignment of axis of loading, the existence of flaws such as induced cracks during shaping the samples or bubbles created during application of the adhesive are considered. Microtensile experiments are performed simultaneously to measure bond strength and modes of failure. These are compared with the FEA results. Results: The relative bonding strength and its standard deviation for the specimens with different geometries measured through the microtensile tests confirm the findings of the FEA. The hourglass shape samples show lower tensile bond strength and standard deviation compared to the stick and dumbbell shape samples. ANOVA analysis confirms no significant difference between dumbbell and stick geometry results, and major differences of these two geometries compared to hourglass shape measured values. Induced flaws in the adhesive and misalignment of the angle of application of load have significant effect on the microtensile bond strength. Using adhesive with higher modulus the differences between the bond strength of the three sample geometries increase. Significance: The result of the research clarifies the importance of the sample geometry chosen in measuring the bond strength. It quantifies the effect of the imperfections on the bond strength for each of the sample geometries through a systematic and all embracing study. The results explain the reasons of the large spread of the microtensile test results reported by various researchers working in different labs and the need for standardization of the test method and sample shape used in evaluation of the dentin-adhesive bonding system. © 2007 Academy of Dental Materials.
Resumo:
A set of cylindrical porous titanium test samples were produced using the three-dimensional printing and sintering method with samples sintered at 900 °C, 1000 °C, 1100 °C, 1200 °C or 1300 °C. Following compression testing, it was apparent that the stress-strain curves were similar in shape to the curves that represent cellular solids. This is despite a relative density twice as high as what is considered the threshold for defining a cellular solid. As final sintering temperature increased, the compressive behaviour developed from being elastic-brittle to elastic-plastic and while Young's modulus remained fairly constant in the region of 1.5 GPa, there was a corresponding increase in 0.2% proof stress of approximately 40-80 MPa. The cellular solid model consists of two equations that predict Young's modulus and yield or proof stress. By fitting to experimental data and consideration of porous morphology, appropriate changes to the geometry constants allow modification of the current models to predict with better accuracy the behaviour of porous materials with higher relative densities (lower porosity).
Resumo:
Software Product-Line Engineering has emerged in recent years, as an important strategy for maximising reuse within the context of a family of related products. In current approaches to software product-lines, there is general agreement that the definition of a reference-architecture for the product-line is an important step in the software engineering process. In this paper we introduce ADLARS, a new form of architecture Description language that places emphasis on the capture of architectural relationships. ADLARS is designed for use within a product-line engineering process. The language supports both the definition of architectural structure, and of important architectural relationships. In particular it supports capture of the relationships between product features, component and task architectures, interfaces and parameter requirements.
Resumo:
Optimizing and editing enterprise software systems, after the implementation process has started, is widely recognized to be an expensive process. This has led to increasing emphasis on locating mistakes within software systems at the design stage, to help minimize development costs. There is increasing interest in the field of architecture evaluation techniques that can identify problems at the design stage, either within complete, or partially complete architectures. Most current techniques rely on manual review-based evaluation methods that require advanced skills from architects and evaluators. We are currently considering what a formal Architecture Description Language (ADL) can contribute to the process of architecture evaluation and validation. Our investigation is considering the inter-relationships between the activities performed during the architecture evaluation process, the characteristics an ADL should possess to support these activities, and the tools needed to provide convenient access to, and presentation of architectural information.