237 resultados para Defined Daily Dose
Resumo:
For the delivery of intensity-modulated radiation therapy (IMRT), highly modulated fields are used to achieve dose conformity across a target tumour volume. Recent in vitro evidence has demonstrated significant alterations in cell survival occurring out-of-field which cannot be accounted for on the basis of scattered dose. The radiobiological effect of area, dose and dose-rate on out-of-field cell survival responses following exposure to intensity-modulated radiation fields is presented in this study. Cell survival was determined by clonogenic assay in human prostate cancer (DU-145) and primary fibroblast (AG0-1522) cells following exposure to different modulated field configurations delivered using a X-Rad 225 kVp x-ray source. Uniform survival responses were compared to in- and out-of-field responses in which 25-99% of the cell population was shielded. Dose delivered to the out-of-field region was varied from 1.6-37.2% of that delivered to the in-field region using different levels of brass shielding. Dose rate effects were determined for 0.2-4 Gy min⁻¹ for uniform and modulated exposures with no effect seen in- or out-of-field. Survival responses showed little dependence on dose rate and area in- and out-of-field with a trend towards increased survival with decreased in-field area. Out-of-field survival responses were shown to scale in proportion to dose delivered to the in-field region and also local dose delivered out-of-field. Mathematical modelling of these findings has shown survival response to be highly dependent on dose delivered in- and out-of-field but not on area or dose rate. These data provide further insight into the radiobiological parameters impacting on cell survival following exposure to modulated irradiation fields highlighting the need for refinement of existing radiobiological models to incorporate non-targeted effects and modulated dose distributions.
Resumo:
Purpose: The aim of this work was to determine if volumetric modulated arc therapy (VMAT) plans, created for constant dose-rate (cdrVMAT) delivery are a viable alternative to step and shoot five-field intensity modulated radiation therapy (IMRT). Materials and methods: The cdrVMAT plans, inverse planned on a treatment planning system with no solution to account for couch top or rails, were created for delivery on a linear accelerator with no variable dose rate control system. A series of five-field IMRT and cdrVMAT plans were created using dual partial arcs (gantry rotating between 260° and 100°) with 4° control points for ten prostate patients with the average rectal constraint incrementally increased. Pareto fronts were compared for the planning target volume homogeneity and average rectal dose between the two techniques for each patient. Also investigated were tumour control probability and normal tissue complication probability values for each technique. The delivery parameters [monitor units (MU) and time] and delivery accuracy of the IMRT and VMAT plans were also compared. Results: Pareto fronts showed that the dual partial arc plans were superior to the five-field IMRT plans, particularly for the clinically acceptable plans where average rectal doses were less for rotational plans (p = 0·009) with no statistical difference in target homogeneity. The cdrVMAT plans had significantly more MU (p = 0·005) but the average delivery time was significantly less than the IMRT plans by 42%. All clinically acceptable cdrVMAT plans were accurate in their delivery (gamma 99·2 ± 1·1%, 3%3 mm criteria). Conclusions Accurate delivery of dual partial arc cdrVMAT avoiding the couch top and rails has been demonstrated.
Resumo:
The purpose of this randomized controlled trial was to investigate the dose-response effect of fruit and vegetable (F&V) intake on insulin resistance (IR) in people who are overweight and at high risk of cardiovascular disease (CVD).
Resumo:
Systematic reviews have considerable potential to provide evidence-based data to aid clinical decision-making. However, there is growing recognition that trials involving mechanical ventilation lack consistency in the definition and measurement of ventilation outcomes, creating difficulties in combining data for meta-analyses. To address the inconsistency in outcome definitions, international standards for trial registration and clinical trial protocols published recommendations, effectively setting the “gold standard” for reporting trial outcomes. In this Critical Care Perspective, we review the problems resulting from inconsistent outcome definitions and inconsistent reporting of outcomes (outcome sets). We present data highlighting the variability of the most commonly reported ventilation outcome definitions. Ventilation outcomes reported in trials over the last 6 years typically fall into four domains: measures of ventilator dependence; adverse outcomes; mortality; and resource use. We highlight the need, first, for agreement on outcome definitions and, second, for a minimum core outcome set for trials involving mechanical ventilation. A minimum core outcome set would not restrict trialists from measuring additional outcomes, but would overcome problems of variability in outcome selection, measurement, and reporting, thereby enhancing comparisons across trials.
Resumo:
Purpose: Aspirin use is associated with reduced risk of, and death from, prostate cancer. Our aim was to determine whether low-dose aspirin use after a prostate cancer diagnosis was associated with reduced prostate cancer-specific mortality.
Methods: A cohort of newly diagnosed prostate cancer patients (1998–2006) was identified in the UK Clinical Practice Research Datalink (confirmed by cancer registry linkage). A nested case–control analysis was conducted using conditional logistic regression to compare aspirin usage in cases (prostate cancer deaths) with up to three controls (matched by age and year of diagnosis).
Results: Post-diagnostic low-dose aspirin use was identified in 52 % of 1,184 prostate cancer-specific deaths and 39 % of 3,531 matched controls (unadjusted OR 1.51, 95 % CI 1.19, 1.90; p < 0.001). After adjustment for confounders including treatment and comorbidities, this association was attenuated (adjusted OR 1.02 95 % CI 0.78, 1.34; p = 0.86). Adjustment for estrogen therapy accounted for the majority of this attenuation. There was also no evidence of dose–response association after adjustments. Compared with no use, patients with 1–11 prescriptions and 12 or more prescriptions had adjusted ORs of 1.07 (95 % CI 0.78, 1.47; p = 0.66) and 0.97 (95 % CI 0.69, 1.37; p = 0.88), respectively. There was no evidence of a protective association between low-dose aspirin use in the year prior to diagnosis and prostate cancer-specific mortality (adjusted OR 1.04 95 % CI 0.89, 1.22; p = 0.60).
Conclusion: We found no evidence of an association between low-dose aspirin use before or after diagnosis and risk of prostate cancer-specific mortality, after potential confounders were accounted for, in UK prostate cancer patients.
Resumo:
Doses from CT examinations are difficult to estimate. However, they are requested more frequently due to the increase in CT examinations. In particular, fetal dose estimations are frequently required for patients who have discovered, subsequent to the examination, that they were pregnant when the examination was conducted. A computer model has been developed to facilitate such dose calculations. This model combines empirical beam data with anatomical information. The model has been verified using thermoluminescent dosemeter (TLD) readings of internal and surface dose from both phantoms and patients, including intrauterine doses for patients undergoing afterloading gynaecological intracavitary treatment. Although only limited experimental data were available, the results indicate that the model accurately predicts uterine doses within acceptable errors. This approach has been validated for fetal dose estimation. The model was also used in a comparison with the nationally available CT dose data from the National Radiological Protection Board (NRPB). The two models were found to be in agreement for fetal dose estimations.
Resumo:
This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was developed, and validated, to track MLC positional accuracy with the rotational and static gantry picket fence tests using an integrated electronic portal image. This software was used to monitor MLC daily performance over a 1 year period for two Varian TrueBeam linear accelerators, with the results directly compared with MLC positions determined using leaf trajectory log files. This software was validated by introducing known shifts and collimator errors. Skewness of the MLCs was found to be 0.03 ± 0.06° (mean ±1 standard deviation (SD)) and was dependent on whether the collimator was rotated manually or automatically. Trajectory log files, analysed using in-house software, showed average MLC positioning errors with a magnitude of 0.004 ± 0.003 mm (rotational) and 0.004 ± 0.011 mm (static) across two TrueBeam units over 1 year (mean ±1 SD). These ranges, as indicated by the SD, were lower than the related average MLC positioning errors of 0.000 ± 0.025 mm (rotational) and 0.000 ± 0.039 mm (static) that were obtained using the in-house EPID based software. The range of EPID measured MLC positional errors was larger due to the inherent uncertainties of the procedure. Over the duration of the study, multiple MLC positional errors were detected using the EPID based software but these same errors were not detected using the trajectory log files. This work shows the importance of increasing linac specific QC when phantom-less methodologies, such as the use of log files, are used to reduce patient specific QC. Tolerances of 0.25 mm have been created for the MLC positional errors using the EPID-based automated picket fence test. The software allows diagnosis of any specific leaf that needs repair and gives an indication as to the course of action that is required.
Resumo:
Objective: To investigate the association between serum 25-hydroxyvitamin D concentrations (25(OH)D) and mortality in a large consortium of cohort studies paying particular attention to potential age, sex, season, and country differences.
Design: Meta-analysis of individual participant data of eight prospective cohort studies from Europe and the US.
Setting: General population.
Participants: 26 018 men and women aged 50-79 years
Main outcome measures: All-cause, cardiovascular, and cancer mortality.
Results: 25(OH)D concentrations varied strongly by season (higher in summer), country (higher in US and northern Europe) and sex (higher in men), but no consistent trend with age was observed. During follow-up, 6695 study participants died, among whom 2624 died of cardiovascular diseases and 2227 died of cancer. For each cohort and analysis, 25(OH)D quintiles were defined with cohort and subgroup specific cut-off values. Comparing bottom versus top quintiles resulted in a pooled risk ratio of 1.57 (95% CI 1.36 to 1.81) for all-cause mortality. Risk ratios for cardiovascular mortality were similar in magnitude to that for all-cause mortality in subjects both with and without a history of cardiovascular disease at baseline. With respect to cancer mortality, an association was only observed among subjects with a history of cancer (risk ratio, 1.70 (1.00 to 2.88)). Analyses using all quintiles suggest curvilinear, inverse, dose-response curves for the aforementioned relationships. No strong age, sex, season, or country specific differences were detected. Heterogeneity was low in most meta-analyses.
Conclusions: Despite levels of 25(OH)D strongly varying with country, sex, and season, the association between 25(OH)D level and all-cause and cause-specific mortality was remarkably consistent. Results from a long term randomised controlled trial addressing longevity are being awaited before vitamin D supplementation can be recommended in most individuals with low 25(OH)D levels.
Resumo:
Aim: Chloral hydrate is generally considered a safe and effective single dosing procedural sedative for neonates in the clinical setting. However, its safety profile as a repetitive dosing maintenance sedative is largely unknown. This study aimed to document current administration practices of chloral hydrate in the Neonatal Unit, Royal Children's Hospital, Melbourne, Australia, over a 6-month period.
Methods: Patients who had been prescribed chloral hydrate during the specified audit period were recruited into the study and prospectively followed for a period of 28 days, or until they were discharged from the unit. Demographic data were collected on recruitment, and daily documentation of chloral hydrate administration was recorded.
Results: A total of 238 doses of chloral hydrate were administered to a cohort of 32 patients during the study period. The majority of the audited doses (84%) were ordered as repeating doses. Doses were more likely to be given at night than during the day, and the median dosage for repetitive dosing was found to be above the study site's recommended dosing range. Pre-dose and/or post-dose assessment of distress/agitation accompanied dosage approximately half of the time. The audit did not reveal any recognisable pattern of sedation maintenance or weaning process for patients who received multiple doses.
Conclusions: Health-care professionals caring for hospitalised infants should be made aware of the potential risks of chloral hydrate as a repetitive dosing sedative, and of the importance of systematically evaluating the appropriateness and effectiveness of utilising such pharmacological intervention for managing and treating distress.
Resumo:
INTRODUCTION: Recent observational studies indicate that post-diagnostic use of aspirin in breast cancer patients may protect against cancer progression perhaps by inhibiting cyclooxygenase-2 dependent mechanisms. Evidence also supports a crucial role for interactions between tumour cells and circulating platelets in cancer growth and dissemination, therefore, use of low-dose aspirin may reduce the risk of death from cancer in breast cancer patients.
METHODS: A cohort of newly diagnosed breast cancer patients (1998 to 2006) were identified in the UK Clinical Practice Research Datalink (and confirmed by cancer registry linkage). Cancer-specific deaths were identified up to 2011 from Office for National Statistics mortality data. A nested case-control analysis was conducted using conditional logistic regression to compare post-diagnostic aspirin exposure using General Practice prescription data in 1,435 cases (breast cancer deaths) with 5,697 controls (matched by age and year of diagnosis).
RESULTS: After breast cancer diagnosis, 18.3% of cancer-specific deaths and 18.5% of matched controls received at least one prescription for low-dose aspirin, corresponding to an odds ratio (OR) of 0.98 (95% CI 0.83, 1.15). Adjustment for potential confounders (including stage and grade) had little impact on this estimate. No dose response relationship was observed when the number of tablets was investigated and no associations were seen when analyses were stratified by receipt of prescriptions for aspirin in the pre-diagnostic period, by stage at diagnosis or by receipt of prescriptions for hormone therapy.
CONCLUSIONS: Overall, in this large population-based cohort of breast cancer patients, there was little evidence of an association between receipt of post-diagnostic prescriptions for low-dose aspirin and breast cancer-specific death. However, information was not available on medication compliance or over-the-counter use of aspirin, which may have contributed to the null findings.