167 resultados para Minorities in medicine


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was developed, and validated, to track MLC positional accuracy with the rotational and static gantry picket fence tests using an integrated electronic portal image. This software was used to monitor MLC daily performance over a 1 year period for two Varian TrueBeam linear accelerators, with the results directly compared with MLC positions determined using leaf trajectory log files. This software was validated by introducing known shifts and collimator errors. Skewness of the MLCs was found to be 0.03 ± 0.06° (mean ±1 standard deviation (SD)) and was dependent on whether the collimator was rotated manually or automatically. Trajectory log files, analysed using in-house software, showed average MLC positioning errors with a magnitude of 0.004 ± 0.003 mm (rotational) and 0.004 ± 0.011 mm (static) across two TrueBeam units over 1 year (mean ±1 SD). These ranges, as indicated by the SD, were lower than the related average MLC positioning errors of 0.000 ± 0.025 mm (rotational) and 0.000 ± 0.039 mm (static) that were obtained using the in-house EPID based software. The range of EPID measured MLC positional errors was larger due to the inherent uncertainties of the procedure. Over the duration of the study, multiple MLC positional errors were detected using the EPID based software but these same errors were not detected using the trajectory log files. This work shows the importance of increasing linac specific QC when phantom-less methodologies, such as the use of log files, are used to reduce patient specific QC. Tolerances of 0.25 mm have been created for the MLC positional errors using the EPID-based automated picket fence test. The software allows diagnosis of any specific leaf that needs repair and gives an indication as to the course of action that is required.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Social and psychological interventions are often complex. Understanding randomized controlled trials (RCTs) of these complex interventions requires a detailed description of the interventions tested and the methods used to evaluate them; however, RCT reports often omit, or inadequately report, this information. Incomplete and inaccurate reporting hinders the optimal use of research, wastes resources, and fails to meet ethical obligations to research participants and consumers. In this article, we explain how reporting guidelines have improved the quality of reports in medicine and describe the ongoing development of a new reporting guideline for RCTs: Consolidated Standards of Reporting Trials-SPI (an extension for social and psychological interventions). We invite readers to participate in the project by visiting our website, in order to help us reach the best-informed consensus on these guidelines (http://tinyurl.com/CONSORT-study).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An algorithm based only on the impedance cardiogram (ICG) recorded through two defibrillation pads, using the strongest frequency component and amplitude, incorporated into a defibrillator could determine circulatory arrest and reduce delays in starting cardiopulmonary resuscitation (CPR). Frequency analysis of the ICG signal is carried out by integer filters on a sample by sample basis. They are simpler, lighter and more versatile when compared to the FFT. This alternative approach, although less accurate, is preferred due to the limited processing capacity of devices that could compromise real time usability of the FFT. These two techniques were compared across a data set comprising 13 cases of cardiac arrest and 6 normal controls. The best filters were refined on this training set and an algorithm for the detection of cardiac arrest was trained on a wider data set. The algorithm was finally tested on a validation set. The ICG was recorded in 132 cardiac arrest patients (53 training, 79 validation) and 97 controls (47 training, 50 validation): the diagnostic algorithm indicated cardiac arrest with a sensitivity of 81.1% (77.6-84.3) and specificity of 97.1% (96.7-97.4) for the validation set (95% confidence intervals). Automated defibrillators with integrated ICG analysis have the potential to improve emergency care by lay persons enabling more rapid and appropriate initiation of CPR and when combined with ECG analysis they could improve on the detection of cardiac arrest.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This overview will demonstrate that cough is a common and potentially expensive health-care problem. Improvement in the quality of care of those with cough has been the focus of study for a variety of disciplines in medicine. The purpose of the Cough Guideline and Expert Panel is to synthesize current knowledge in a form that will aid clinical decision-making for the diagnosis and management of cough across disciplines and also identify gaps in knowledge and treatment options.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES:
To examine the feasibility of a main RCT to compare the effectiveness of two frequencies (2 versus 5 times/week) of acupuncture treatment for chronic low back pain (LBP).
METHODS:
Participants (n=30) with chronic LBP were randomised into two groups to receive 10 acupuncture treatments: Low Frequency Group, 2 times/week for five weeks (n=15); High Frequency Group, 5 times/week for two weeks (n=15). The following outcomes were measured blindly at baseline, 2 weeks, 5 weeks, 3 months and 1 year: pain on a VAS, functional disability using the RMDQ, quality of life using the Measure Yourself Medical Outcome Profile (MYMOP-2), psychological impact with the Coping Strategies Questionnaire (CSQ) and Pain Locus of Control (PLC) questionnaire. Two objective outcomes, the Shuttle Walk Test (SWT) and Lateral Trunk Flexibility (LTF), were also measured.
RESULTS:
The compliance rate was 100% for each group. Some of the measurements were shown to be sensitive (VAS, RMDQ, MYMOP-2 Wellbeing). 66-330 participants would be required for a fully powered non-inferiority trial. The groups were balanced at baseline for LBP and demographic characteristics. There were no significant differences between the groups in terms of any of the outcomes, at each follow-up time point. It was notable however that the clinically important improvement in terms of pain, functional disability, quality of life, and SWT in both groups was achieved within the first two weeks, which was maintained at one year follow-up.
CONCLUSIONS:
It is feasible to conduct a main RCT, to compare different frequencies of acupuncture for LBP, using sensitive measurements. Also the trend for early clinically important improvement within a minimum of four measurements is worthy of further study.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The initial composition of acrylic bone cement along with the mixing and delivery technique used can influence its final properties and therefore its clinical success in vivo. The polymerisation of acrylic bone cement is complex with a number of processes happening simultaneously. Acrylic bone cement mixing and delivery systems have undergone several design changes in their advancement, although the cement constituents themselves have remained unchanged since they were first used. This study was conducted to determine the factors that had the greatest effect on the final properties of acrylic bone cement using a pre-filled bone cement mixing and delivery system. A design of experiments (DoE) approach was used to determine the impact of the factors associated with this mixing and delivery method on the final properties of the cement produced. The DoE illustrated that all factors present within this study had a significant impact on the final properties of the cement. An optimum cement composition was hypothesised and tested. This optimum recipe produced cement with final mechanical and thermal properties within the clinical guidelines and stated by ISO 5833 (International Standard Organisation (ISO), International standard 5833: implants for surgery—acrylic resin cements, 2002), however the low setting times observed would not be clinically viable and could result in complications during the surgical technique. As a result further development would be required to improve the setting time of the cement in order for it to be deemed suitable for use in total joint replacement surgery.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cystic fibrosis (CF) lung disease is characterized by chronic bacterial infection and an unremitting inflammatory response, which are responsible for most of CF morbidity and mortality. The median expected survival has increased from <6 mo in 1940 to >38 yr now. This dramatic improvement, although not great enough, is due to the development of therapies directed at secondary disease pathologies, especially antibiotics. The importance of developing treatments directed against the vigorous inflammatory response was realized in the 1990s. New therapies directed toward the basic defect are now visible on the horizon. However, the impact of these drugs on downstream pathological consequences is unknown. It is likely that antibiotics and anti-inflammatory drugs will remain an important part of the maintenance regimen for CF in the foreseeable future. Current and future antibiotic and anti-inflammatory therapies for CF are reviewed. © 2013 Cold Spring Harbor Laboratory Press; all rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to increase understanding of the mechanism and dominant drivers influencing phase separation during ram extrusion of calcium phosphate (CaP) paste for orthopaedic applications. The liquid content of extrudate was determined, and the flow of liquid and powder phases within the syringe barrel during extrusion were observed, subject to various extrusion parameters. Increasing the initial liquid-to-powder mass ratio, LPR, (0.4-0.45), plunger rate (5-20 mm/min), and tapering the barrel exit (45°-90°) significantly reduced the extent of phase separation. Phase separation values ranged from (6.22 ± 0.69 to 18.94 ± 0.69 %). However altering needle geometry had no significant effect on phase separation. From powder tracing and liquid content determination, static zones of powder and a non-uniform liquid distribution was observed within the barrel. Measurements of extrudate and paste LPR within the barrel indicated that extrudate LPR remained constant during extrusion, while LPR of paste within the barrel decreased steadily. These observations indicate the mechanism of phase separation was located within the syringe barrel. Therefore phase separation can be attributed to either; (1) the liquid being forced downstream by an increase in pore pressure as a result of powder consolidation due to the pressure exerted by the plunger or (2) the liquid being drawn from paste within the barrel, due to suction, driven by dilation of the solids matrix at the barrel exit. Differentiating between these two mechanisms is difficult; however results obtained suggest that suction is the dominant phase separation mechanism occurring during extrusion of CaP paste.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To limit toxicity to normal tissues adjacent to the target tumour volume, radiotherapy is delivered using fractionated regimes whereby the total prescribed dose is given as a series of sequential smaller doses separated by specific time intervals. The impact of fractionation on out-of-field survival and DNA damage responses was determined in AGO-1522 primary human fibroblasts and MCF-7 breast tumour cells using uniform and modulated exposures delivered using a 225 kVp x-ray source. Responses to fractionated schedules (two equal fractions delivered with time intervals from 4 h to 48 h) were compared to those following acute exposures. Cell survival and DNA damage repair measurements indicate that cellular responses to fractionated non-uniform exposures differ from those seen in uniform exposures for the investigated cell lines. Specifically, there is a consistent lack of repair observed in the out-of-field populations during intervals between fractions, confirming the importance of cell signalling to out-of-field responses in a fractionated radiation schedule, and this needs to be confirmed for a wider range of cell lines and conditions.