225 resultados para GAUSSIAN BEAMS
Design proposals for the debonding strengths of FRP strengthened RC beams in the Chinese design code
Resumo:
Multiple Gaussian pulse interactions and scattering in the nonlinear layered dielectric structures have been examined. The Gaussian pulses with different centre frequencies and lengths are incident at oblique angles on the finite stack of nonlinear dielectric layers. The properties of the reflected and refracted waveforms and the effects of the structure and the incident pulses' parameters on the mixing process are discussed. It is shown that the efficiency of forward emission at the combinatorial frequency can be considerably increased when the wavelengths of interacting pulses are close to the edges of electromagnetic bandgap. © 2012 IEEE.
Resumo:
The pulse mixing and scattering by finite nonlinear Thue-Morse quasi-periodic dielectric multilayered structure illuminated by two Gaussian pulses with different centre frequencies and lengths are investigated. The three-wave mixing technique is applied to study the nonlinear processes. The properties of the scattered waveforms and the effects of the structure and the incident pulses' parameters on the mixing process are discussed.
Resumo:
The properties of mixing and scattering of two non-collinear Gaussian pulses with different centre frequencies and lengths, incident on the finite nonlinear periodic layered dielectric structures, have been analysed. It is shown that at the backward emission grows with the number of layers and can reach the level of the forward emission in the direction of combinatorial frequency scattering.
Resumo:
We propose the inverse Gaussian distribution, as a less complex alternative to the classical log-normal model, to describe turbulence-induced fading in free-space optical (FSO) systems operating in weak turbulence conditions and/or in the presence of aperture averaging effects. By conducting goodness of fit tests, we define the range of values of the scintillation index for various multiple-input multiple-output (MIMO) FSO configurations, where the two distributions approximate each other with a certain significance level. Furthermore, the bit error rate performance of two typical MIMO FSO systems is investigated over the new turbulence model; an intensity-modulation/direct detection MIMO FSO system with Q-ary pulse position modulation that employs repetition coding at the transmitter and equal gain combining at the receiver, and a heterodyne MIMO FSO system with differential phase-shift keying and maximal ratio combining at the receiver. Finally, numerical results are presented that validate the theoretical analysis and provide useful insights into the implications of the model parameters on the overall system performance. © 2011 IEEE.
Resumo:
Laser accelerated proton beams have been proposed to be used in different research fields. A great interest has risen for the potential replacement of conventional accelerating machines with laser-based accelerators, and in particular for the development of new concepts of more compact and cheaper hadrontherapy centers. In this context the ELIMED (ELI MEDical applications) research project has been launched by INFN-LNS and ASCR-FZU researchers within the pan-European ELI-Beamlines facility framework. The ELIMED project aims to demonstrate the potential clinical applicability of optically accelerated proton beams and to realize a laser-accelerated ion transport beamline for multi-disciplinary user applications. In this framework the eye melanoma, as for instance the uveal melanoma normally treated with 62 MeV proton beams produced by standard accelerators, will be considered as a model system to demonstrate the potential clinical use of laser-driven protons in hadrontherapy, especially because of the limited constraints in terms of proton energy and irradiation geometry for this particular tumour treatment. Several challenges, starting from laser-target interaction and beam transport development up to dosimetry and radiobiology, need to be overcome in order to reach the ELIMED final goals. A crucial role will be played by the final design and realization of a transport beamline capable to provide ion beams with proper characteristics in terms of energy spectrum and angular distribution which will allow performing dosimetric tests and biological cell irradiation. A first prototype of the transport beamline has been already designed and other transport elements are under construction in order to perform a first experimental test with the TARANIS laser system by the end of 2013. A wide international collaboration among specialists of different disciplines like Physics, Biology, Chemistry, Medicine and medical doctors coming from Europe, Japan, and the US is growing up around the ELIMED project with the aim to work on the conceptual design, technical and experimental realization of this core beamline of the ELI Beamlines facility. © 2013 SPIE.
Resumo:
Gabions are stone-filled wire containers which are frequently used as retaining walls. However, due to their high mass, relatively low cost and visual appeal, a row of single gabion blocks, joined at the ends, has the potential to be used as a roadside impact absorption device where traditional steel or concrete devices may not be suitable. To evaluate such application, the shear and bending deformation of gabions under vehicle impact need to be investigated. In this paper, the shear response of a single gabion block is analytically modelled and a gabion beam multibody model is developed using a discretisation method to capture the deformability of the gabion structure. The material properties of the gabion beam are adopted from experimental values available in the literature and the modelling is statically validated over a three-point bending test and a distributed loading test. The results show that the discretised multibody modelling can be effectively used to describe the static deformation behaviour of gabion blocks.
Resumo:
Studies regarding the radiobiological effects of low dose radiation, microbeam irradiation services have been developed in the world and today laser acceleration of protons and heavy ions may be used in radiation therapy. The application of different facilities is essential for studying bystander effects and relating signalling phenomena in different cells or tissues. In particular the use of ion beams results advantageous in cancer radiotherapy compared to more commonly used X-rays, since the ability of ions in delivering lethal amount of doses into the target tumour avoiding or limiting damage to the contiguous healthy tissues. At the INFN-LNS in Catania, a multidisciplinary radiobiology group is strategically structured aimed to develop radiobiological research, finalised to therapeutic applications, compatible with the use of high dose laser-driven ion beams. The characteristic non-continuous dose rates with several orders of magnitude of laser-driven ion beams makes this facility very interesting in the cellular systems' response to ultra-high dose rates with non-conventional pulse time intervals cellular studies. Our group have projected to examine the effect of high dose laser-driven ion beams on two cellular types: foetal fibroblasts (normal control cells) and DU145 (prostate cancer cells), studying the modulation of some different bio-molecular parameters, in particular cell proliferation and viability, DNA damage, redox cellular status, morphological alterations of both the cytoskeleton components and some cell organelles and the possible presence of apoptotic or necrotic cell death. Our group performed preliminary experiments with high energy (60 MeV), dose rate of 10 Gy/min, doses of 1, 2, 3 Gy and LET 1 keV/µm on human foetal fibroblasts (control cells). We observed that cell viability was not influenced by the characteristics of the beam, the irradiation conditions or the analysis time. Conversely, DNA damage was present at time 0, immediately following irradiation in a dose-dependent manner. The analysis of repair capability showed that the cells irradiated with 1 and 2 Gy almost completely recovered from the damage, but not, however, 3 Gy treated cells in which DNA damage was not recovered. In addition, the results indicate the importance of the use of an appropriate control in radiobiological in vitro analysis.