155 resultados para Acomodación ocular
Resumo:
PURPOSE: To assess determinants of patients' willingness to pay (WTP) for potential components of a multi-tiered cataract surgical package offered by a non-governmental organization (NGO) in rural China. DESIGN: Cross-sectional study. METHODS: Demographic and clinical data were collected from 505 patients presenting for cataract screening or surgery in Yangjiang, China. Willingness to pay for potential enhancements to the current surgery package was assessed using a bidding format with random payment cards. RESULTS: Among 426 subjects (84.4%) completing interviews, the mean age was 73.9 ± 7.3 years, 67.6% were women and 73% (n = 310) would pay for at least one offering, with 33-38% WTP for each item. Among those who would pay, the mean WTP for food was US$1.68 ± 0.13, transportation US$3.24 ± 0.25, senior surgeon US$50.0 ± 3.36 and US$89.4 ± 4.19 for an imported intra-ocular lens (IOL). The estimated total recovery from these enhancements under various assumptions would be US$20-50 (compared to the current programme price of US$65). In multivariate models, WTP for the senior surgeon increased with knowledge of a person previously operated for cataract (OR = 2.13, 95% CI 1.42-3.18, p < 0.001). Willingness to pay for the imported IOL increased with knowledge of a previously operated person (OR = 1.85, 95% CI 1.24-2.75, p < 0.01) and decreased with age >75 years (OR = 0.61, 0.40-0.93, p < 0.05). CONCLUSIONS: Opportunities exist to increase cataract programme revenues through multi-tiered offerings in this setting, allowing greater subsidization of low-income patients. Personal familiarity with cataract surgery is important in determining WTP. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
Resumo:
BACKGROUND: We sought to determine whether corneal biomechanical parameters are predictive of reduction in axial length after anti-metabolite trabeculectomy. METHODS: Chinese subjects undergoing trabeculectomy with mitomycin C by a single experienced surgeon underwent the following measurements: Corneal hysteresis (CH, Ocular Response Analyzer, Reichert Ophthalmic Instruments), Goldmann intra-ocular pressure (IOP), central corneal thickness (CCT) and axial length (AL, IOLMaster, Carl Zeiss Meditec, Dublin, CA) were measured pre-operatively, and AL, CH and IOP were measured 1 day and 1 week post-operatively. RESULTS: Mean age of 31 subjects was 52.0 ± 15.2 years, and 15 (48.4%) were female. The mean pre-operative IOP of 21.4 ± 9.3 mmHg was reduced to 8.2 ± 4.6 mmHg 1 day and 11.0 ± 4.4 mmHg 1 week post-operatively (p < 0.001). AL declined from 22.99 ± 0.90 to 22.76 ± 0.87 mm at 1 day and 22.74 ± 0.9 mm at 1 week; 30/31 (%) eyes had a decline in AL (p < 0.001, sign test). In multivariate linear regression models including post-operative data from 1 day and 1 week, greater decline in Goldmann IOP (p < 0.0001, greater pre-op axial length (p < 0.001) and lower pre-operative CH (p = 0.03), were all associated with greater decline in post-operative axial length. CONCLUSIONS: Eyes with lesser ability of the ocular coat to absorb energy (lower CH) had significantly greater decrease in axial length after trabeculectomy-induced IOP-lowering.
Resumo:
Purpose: To investigate how potentially functional genetic variants are coinherited on each of four common complement factor H (CFH) and CFH-related gene haplotypes and to measure expression of these genes in eye and liver tissues.
Methods: We sequenced the CFH region in four individuals (one homozygote for each of four common CFH region haplotypes) to identify all genetic variants. We studied associations between the haplotypes and AMD phenotypes in 2157 cases and 1150 controls. We examined RNA-seq profiles in macular and peripheral retina and retinal pigment epithelium/choroid/sclera (RCS) from eight eye donors and three liver samples.
Results: The haplotypic coinheritance of potentially functional variants (including missense variants, novel splice sites, and the CFHR3–CFHR1 deletion) was described for the four common haplotypes. Expression of the short and long CFH transcripts differed markedly between the retina and liver. We found no expression of any of the five CFH-related genes in the retina or RCS, in contrast to the liver, which is the main source of the circulating proteins.
Conclusions: We identified all genetic variants on common CFH region haplotypes and described their coinheritance. Understanding their functional effects will be key to developing and stratifying AMD therapies. The small scale of our expression study prevented us from investigating the relationships between CFH region haplotypes and their expression, and it will take time and collaboration to develop epidemiologic-scale studies. However, the striking difference between systemic and ocular expression of complement regulators shown in this study suggests important implications for the development of intraocular and systemic treatments.
Resumo:
Microneedles (MNs) are minimally invasive devices consisting of numerous micron-sized projections amassed on a baseplate, designed to enhance transdermal drug delivery. When applied to the skin, the needles puncture the outermost layer, the stratum corneum, forming aqueous conduits through which drugs can diffuse to the dermal microcirculation. With an average length of 50-900 μm, MNs are short enough to avoid stimulation of dermal nerves and do not induce bleeding, yet gain access to the skin's rich microcirculation for drug delivery. MNs have been extensively investigated for drug and vaccine delivery, demonstrating their efficacy at increasing the number of compounds amenable to delivery through the skin. This chapter discusses the materials and fabrication methods involved in MN production, alongside the different types of MN arrays and their delivery capabilities. The field has expanded to consider novel applications of MNs including minimally invasive patient monitoring, ocular delivery and enhanced administration of cosmeceuticals. Patient usage and effects on the skin are also considered in terms of safety, efficacy and acceptability. The next steps in MN development are to focus on the scale-up of manufacturing processes, a challenge considering the number of small-scale methods detailed in the literature. Regulatory guidance is awaited to direct this, alongside provision of clearer patient instruction for safe and effective use of MN devices. MNs have tremendous potential to yield real benefits for patients and industry and with continued research in the key areas highlighted, this will begin to be realised over the next number of years.
Resumo:
PURPOSE: Glaucoma patients are still at risk of becoming blind. It is of clinical significance to determine the risk of blindness and its causes to prevent its occurrence. This systematic review estimates the number of treated glaucoma patients with end-of-life visual impairment (VI) and blindness and the factors that are associated with this.
METHODS: A systematic literature search in relevant databases was conducted in August 2014 on end-of-life VI. A total of 2574 articles were identified, of which 5 on end-of-life VI. Several data items were extracted from the reports and presented in tables.
RESULTS: All studies had a retrospective design. A considerable number of glaucoma patients were found to be blind at the end of their life; with up to 24% unilateral and 10% bilateral blindness. The following factors were associated with blindness: (1) baseline severity of visual field loss: advanced stage of glaucoma or substantial visual field loss at the initial visit; (2) factors influencing progression: fluctuation of intraocular pressure (IOP) during treatment, presence of pseudoexfoliation, poor patient compliance, higher IOP; (3) longer time period: longer duration of disease and older age at death because of a longer life expectancy; and (4) coexistence of other ocular pathology.
CONCLUSIONS: Further prevention of blindness in glaucoma patients is needed. To reach this goal, it is important to address the risk factors for blindness identified in this review, especially those that can be modified, such as advanced disease at diagnosis, high and fluctuating IOP, and poor compliance.