159 resultados para intergenerational transmission


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we investigate the piezoelectric properties of PbTiO(3) thin films grown by pulsed laser deposition with piezoresponse force microscopy and transmission electron microscopy. The as-grown films exhibit an upward polarization, inhomogeneous distribution of piezoelectric characteristics concerning local coercive fields, and piezoelectric coefficient. In fact, the data obtained reveal imprints during piezoresponse force microscopy measurements, nonlinearity in the piezoelectric deformation, and limited polarization reversal. Moreover, transmission electron microscopy shows the presence of defects near the film/substrate interface, which can be associated with the variations of piezoelectric properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents a new method for determining the transmission network usage by loads and generators, which can then be used for transmission cost/loss allocation in an explainable and justifiable manner. The proposed method is based on solid physical grounds and circuit theory. It relies on dividing the currents through the network into two components; the first one is attributed to power flows from generators to loads, whereas the second one is because of the generators only. Unlike almost all the available methods, the proposed method is assumption free and hence it is more accurate than similar methods even those having some physical basis. The proposed method is validated through a transformer analogy, and theoretical derivations. The method is verified through application to the IEEE 30 bus system and the IEEE 118 test system. The results obtained verified many desirable features of the proposed method. Being more accurate in determining the network usage, in an explainable transparent manner, and in giving accurate cost signals, indicating the best locations to add loads and generation, are among the many desirable features.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a pilot study of a novel observing technique, defocussed transmission spectroscopy, and its application to the study of exoplanet atmospheres using ground-based platforms. Similar to defocussed photometry, defocussed transmission spectroscopy has an added advantage over normal spectroscopy in that it reduces systematic errors due to flat-fielding, PSF variations, slit-jaw imperfections and other effects associated with ground-based observations. For one of the planetary systems studied, WASP-12b, we report a tentative detection of additional Na absorption of 0.12+/-0.03[+0.03]% during transit using a 2A wavelength mask. After consideration of a systematic that occurs mid-transit, it is likely that the true depth is actually closer to 0.15%. This is a similar level of absorption reported in the atmosphere of HD209458b (0.135+/-0.017%, Snellen et al. 2008). Finally, we outline methods that will improve the technique during future observations, based on our findings from this pilot study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method is presented for transmission loss allocation based on the separation of transmission loss caused by load and the loss due to circulating currents between generators. The theoretical basis for and derivation of the loss formulae are presented using simple systems. The concept is then extended to a general power system using the Ybus model. Details of the application of the proposed method to a typical power system are presented along with results from the IEEE 30 bus test system. The results from both the small system and the standard IEEE test system demonstrate the validity of the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we propose general-order transmit antenna selection to enhance the secrecy performance of multiple-input–multiple-output multieavesdropper channels with outdated channel state information (CSI) at the transmitter. To evaluate the effect of the outdated CSI on the secure transmission of the system, we investigate the secrecy performance for two practical scenarios, i.e., Scenarios I and II, where the eavesdropper's CSI is not available at the transmitter and is available at the transmitter, respectively. For Scenario I, we derive exact and asymptotic closed-form expressions for the secrecy outage probability in Nakagami- m fading channels. In addition, we also derive the probability of nonzero secrecy capacity and the \varepsilon -outage secrecy capacity, respectively. Simple asymptotic expressions for the secrecy outage probability reveal that the secrecy diversity order is reduced when the CSI is outdated at the transmitter, and it is independent of the number of antennas at each eavesdropper N_text\rm{E} , the fading parameter of the eavesdropper's channel m_text\rm{E} , and the number of eavesdroppers M . For Scenario II, we make a comprehensive analysis of the average secrecy capacity obtained by the system. Specifically, new closed-form expressions for the exact and asymptotic average secrecy capacity are derived, which are valid for general systems with an arbitrary number of antennas, number of eavesdroppers, and fading severity parameters. Resorting to these results, we also determine a high signal-to-noise ratio power offset to explicitly quantify the impact of the main c- annel and the eavesdropper's channel on the average secrecy capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new class of polarizing surface is proposed that in a given frequency band can reflect incident linearly polarized waves with circular polarization (CP) while at other frequencies is transparent allowing incident waves to transmit unaffected. The proposed structure consists of two parallel anisotropic frequency selective surfaces (FSSs) that independently interact with TE or TM waves, respectively. The FSSs are designed to, respectively, transmit TE and TM waves within the same transmission frequency range, so that the combined structure is transparent to all polarizations in this band. Likewise, the two arrays are designed to, respectively, reflect TE and TM incident waves in a common reflection band, so that all polarizations are fully reflected in this range; if the separation of the two arrays is such that the TE and TM components of an incident wave polarized at slant 45° experience a 90° phase shift, reflection will occur in CP. The concept and performance limitations are theoretically investigated using transmission line theory as well as full wave results. The predicted performance is validated by means of experimental results on a fabricated prototype. The proposed structure is pertinent for employment as a quasi-optical diplexer in CP dual-band systems such as reflector antennas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Nursing homes for older people provide an environment likely to promote the acquisition and spread of meticillin-resistant Staphylococcus aureus (MRSA), putting residents at increased risk of colonisation and infection. It is recognised that infection prevention and control strategies are important in preventing and controlling MRSA transmission.

Objectives: To determine the effects of infection prevention and control strategies for preventing the transmission of MRSA in nursing homes for older people.

Search methods: In August 2013, for this third update, we searched the Cochrane Wounds Group Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library), Database of Abstracts of Reviews of Effects (DARE, The Cochrane Library), Ovid MEDLINE, OVID MEDLINE (In-process and Other Non-Indexed Citations), Ovid EMBASE, EBSCO CINAHL, Web of Science and the Health Technology Assessment (HTA) website. Research in progress was sought through Current Clinical Trials, Gateway to Reseach, and HSRProj (Health Services Research Projects in Progress).

Selection criteria: All randomised and controlled clinical trials, controlled before and after studies and interrupted time series studies of infection prevention and control interventions in nursing homes for older people were eligible for inclusion.

Data collection and analysis: Two review authors independently reviewed the results of the searches. Another review author appraised identified papers and undertook data extraction which was checked by a second review author.

Main results: For this third update only one study was identified, therefore it was not possible to undertake a meta-analysis. A cluster randomised controlled trial in 32 nursing homes evaluated the effect of an infection control education and training programme on MRSA prevalence. The primary outcome was MRSA prevalence in residents and staff, and a change in infection control audit scores which measured adherence to infection control standards. At the end of the 12 month study, there was no change in MRSA prevalence between intervention and control sites, while mean infection control audit scores were significantly higher in the intervention homes compared with control homes.

Authors' conclusions: There is a lack of research evaluating the effects on MRSA transmission of infection prevention and control strategies in nursing homes. Rigorous studies should be conducted in nursing homes, involving residents and staff to test interventions that have been specifically designed for this unique environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High Voltage Direct Current (HVDC) electric power transmission is a promising technology for integrating offshore wind farms and interconnecting power grids in different regions. In order to maintain the DC voltage, droop control has been widely used. Transmission line loss constitutes an import part of the total power loss in a multi-terminal HVDC scheme. In this paper, the relation between droop controller design and transmission loss has been investigated. Different MTDC layout configurations are compared to examine the effect of droop controller design on the transmission loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prevalence of low birth weight is an important aspect of public health which has been linked to increased risk of infant death, increased cost of care, and a range of later life outcomes. Using data from a new Irish cohort study, I document the relationship between birth weight and socio-economic status. The association of maternal education with birth weight does not appear to be due to the timing of birth or complications during pregnancy, even controlling for a wide range of background characteristics. However, results do suggest intergenerational persistence in the transmission of poor early life conditions. Birth weight predicts a number of outcomes at age 9, including test scores, hospital stays and health. An advantage of the data is that I am able to control for a number of typically unmeasured variables. I determine whether parental investments (as measured by the quality of interaction with the child, parenting style, or school quality) mediate the association between birth weight and later indicators. For test scores, there is evidence of non-linearity, and boys are more adversely affected than girls. I also consider whether there are heterogeneous effects by ability using quantile regression. These results are consistent with a literature which finds that there is a causal relationship between early life conditions and later outcomes.