250 resultados para glaucoma surgery


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report a case of malignant glaucoma after diode laser cyclophotocoagulation. METHOD: Case report. RESULTS: A 45-year-old man with uncontrolled secondary glaucoma in his right eye after corneoscleral graft and cataract extraction underwent diode laser cyclophotocoagulation. The right eye was aphakic, with an intact posterior capsule. Two weeks later, the patient presented with blurred vision, edematous cornea, and flat anterior chamber. The posterior capsule was touching the endothelium. Intraocular pressure was 20 mm Hg. Repeated Nd:YAG laser capsulotomy was effective in reversing the malignant glaucoma attack, and the anterior chamber deepened. CONCLUSION: Malignant glaucoma can occur after diode laser cyclophotocoagulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study evaluated the changing trends in glaucoma management in Scotland between 1994 and 2004. Methods: A retrospective analysis of national health statistics in Scotland from 1994 to 2004. The Scottish morbidity record was used to collect information on all episodes of trabeculectomy. Data on number of prescriptions were gathered for individual drugs and also for groups of active ingredient. The population likely to have glaucoma (PLG) was calculated from estimates of prevalence in individuals aged 40 years and older, based on published epidemiological studies. The outcome measures were trabeculectomy rates, corrected for population likely to be at risk of glaucoma (PLG), and prescribing volume and cost for glaucoma medications. Results: Trabeculectomy rates have fallen by 67% from 46 per 1000 PLG in 1994 to 15.4 per 1000 PLG in 2004. Over the same time period, the population likely to be at risk of glaucoma (PLG) increased by 16.6%. The cost of prescribing has increased by 122% over 11 years compared with an increase in number of items per 1000 PLG by 27.5%. In 1994, ß-blockers accounted for 65.2% of prescribed drugs but by 2004 this had dropped to 33%. Since their introduction, the prescribing of prostaglandin analogues has increased rapidly and in 2004, they accounted for 39.4% of prescribed drugs. Conclusion: The increasing useof prostaglandin analogues has led to an increase in prescribing rates and a rapid increase in cost. At the same time, prescribing of ß-blockers has declined and trabeculectomy rates have fallen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sensitivity and specificity of the screening mode of the Humphrey-Welch Allyn frequency-doubling technology (FDT), Octopus tendency-oriented perimetry (TOP), and the Humphrey Swedish Interactive Threshold Algorithm (SITA)-fast (HSF) in patients with glaucoma. DESIGN: A comparative consecutive case series. METHODS: This was a prospective study which took place in the glaucoma unit of an academic department of ophthalmology. One eye of 70 consecutive glaucoma patients and 28 age-matched normal subjects was studied. Eyes were examined with the program C-20 of FDT, G1-TOP, and 24-2 HSF in one visit and in random order. The gold standard for glaucoma was presence of a typical glaucomatous optic disk appearance on stereoscopic examination, which was judged by a glaucoma expert. The sensitivity and specificity, positive and negative predictive value, and receiver operating characteristic (ROC) curves of two algorithms for the FDT screening test, two algorithms for TOP, and three algorithms for HSF, as defined before the start of this study, were evaluated. The time required for each test was also analyzed. RESULTS: Values for area under the ROC curve ranged from 82.5%-93.9%. The largest area (93.9%) under the ROC curve was obtained with the FDT criteria, defining abnormality as presence of at least one abnormal location. Mean test time was 1.08 ± 0.28 minutes, 2.31 ± 0.28 minutes, and 4.14 ± 0.57 minutes for the FDT, TOP, and HSF, respectively. The difference in testing time was statistically significant (P <.0001). CONCLUSIONS: The C-20 FDT, G1-TOP, and 24-2 HSF appear to be useful tools to diagnose glaucoma. The test C-20 FDT and G1-TOP take approximately 1/4 and 1/2 of the time taken by 24 to 2 HSF. © 2002 by Elsevier Science Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the influence of socio-economic factors on severity of glaucoma at presentation

METHODS: All newly diagnosed glaucoma patients at the University Hospitals-NHS, Aberdeen and South Glasgow University Hospitals-NHS, in 2006, were included. Glaucoma was severe at presentation if there was a repeatable visual-field loss with a mean deviation index greater than 12 dB in the Humphreys visual fields test or an absolute paracentral scotoma within the central 5 degrees of the visual fields. Home address was used to determine the Scottish Index of Multiple Deprivation (SIMD) rank. The SIMD rank, demographics and severity of glaucoma at presentation were investigated using general linear modelling.

RESULTS: There were 48 patients with severe glaucoma and 74 patients with non-severe glaucoma. In four, the severity could not be determined. Severity of glaucoma at presentation was significantly associated with SIMD rank, being most severe in patients from areas with the lowest ranks (p = 0.026). Age was a significant factor (p = 0.024), with severe glaucoma being more common in elderly patients.

CONCLUSIONS: Age and socio-economic deprivation were associated with severity of glaucoma at presentation, with patients from areas of higher socio-economic deprivation presenting with more advanced glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To compare the diagnostic performance of accredited glaucoma optometrists (AGO) for both the diagnosis of glaucoma and the decision to treat with that of routine hospital eye care, against a reference standard of expert opinion (a consultant ophthalmologist with a special interest in glaucoma). Methods: A directly comparative, masked, performance study was undertaken in Grampian, Scotland. Of 165 people invited to participate, 100 (61%) were examined. People suspected of having glaucoma underwent, within one month, a full ophthalmic assessment in both a newly established community optometry led glaucoma management scheme and a consultant led hospital eye service. Results: Agreement between the AGO and the consultant ophthalmologist in diagnosing glaucoma was substantial (89%; ? = 0.703, SE = 0.083). Agreement over the need for treatment was also substantial (88%; ? = 0.716, SE = 0.076). The agreement between the trainee ophthalmologists and the consultant ophthalmologist in the diagnosis of glaucoma and treatment recommendation was moderate (83%, ? = 0.541, SE = 0.098, SE = 0.98; and 81%, ? = 0.553, SE = 0.90, respectively). The diagnostic accuracy of the optometrists in detecting glaucoma in this population was high for specificity (0.93 (95% confidence interval, 0.85 to 0.97)) but lower for sensitivity (0.76 (0.57 to 0.89)). Performance was similar when accuracy was assessed for treatment recommendation (sensitivity 0.73 (0.57 to 0.85); specificity 0.96 (0.88 to 0.99)). The differences in sensitivity and specificity between AGO and junior ophthalmologist were not statistically significant. Conclusions: Community optometrists trained in glaucoma provided satisfactory decisions regarding diagnosis and initiation of treatment for glaucoma. With such additional training in glaucoma, optometrists are at least as accurate as junior ophthalmologists but some cases of glaucoma are missed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To identify vision Patient-Reported Outcomes instruments relevant to glaucoma and assess their content validity.

METHODS: MEDLINE, MEDLINE in Process, EMBASE and SCOPUS (to January 2009) were systematically searched. Observational studies or randomised controlled trials, published in English, reporting use of vision instruments in glaucoma studies involving adults were included. In addition, reference lists were scanned to identify additional studies describing development and/or validation to ascertain the final version of the instruments. Instruments' content was then mapped onto a theoretical framework, the World Health Organization International Classification of Functioning, Disability and Health. Two reviewers independently evaluated studies for inclusion and quality assessed instrument content.

RESULTS: Thirty-three instruments were identified. Instruments were categorised into thirteen vision status, two vision disability, one vision satisfaction, five glaucoma status, one glaucoma medication related to health status, five glaucoma medication side effects and six glaucoma medication satisfaction measures according to each instruments' content. The National Eye Institute Visual Function Questionnaire-25, Impact of Vision Impairment and Treatment Satisfaction Survey-Intraocular Pressure had the highest number of positive ratings in the content validity assessment.

CONCLUSION: This study provides a descriptive catalogue of vision-specific PRO instruments, to inform the choice of an appropriate measure of patient-reported outcomes in a glaucoma context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the incidence of glaucoma and elevation of intraocular pressure (IOP) in patients with inflammatory eye disease. Methods: Retrospective review of medical records of 391 consecutive patients with uveitis attending a uveitis clinic of an academic Department of Ophthalmology from January 1999 to August 2002. Demographic, ocular and systemic variables were recorded. The diagnosis and treatment of uveitis were recorded. Uveitis was classified according to standard anatomic, etiological and clinical criteria. "Glaucoma" was defined as elevated IOP (>21 mm Hg) or glaucomatous optic nerve damage requiring medical and/or surgical anti-glaucoma treatment. Kaplan-Maier analysis and log-rank tests were used to evaluate and compare the incidence of glaucoma. Results: The incidence of glaucoma as defined above at 3 and 12 months after acute uveitis was 7.6%. In patients with chronic uveitis (n = 337), the incidence of glaucoma at 1 and 5 years was 6.5% and 11.1%, respectively. There was no statistically significant difference in the incidence of glaucoma between different types of uveitis, idiopathic versus non-idiopathic, and among anterior, intermediate, posterior and panuveitis. Visual loss occurred more frequently in patients with glaucoma than in patients without glaucoma. Conclusion: In patients with chronic inflammatory eye disease, the presence of glaucoma was associated with an increasing risk of visual loss. The incidence of glaucoma increased with time and was similar among the different types of uveitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the correlation between central corneal thickness (CCT) and anterior scleral thickness (ST) in patients of primary open-angle glaucoma (POAG), normal tension glaucoma (NTG), and ocular hypertension (OHT). PATIENTS AND METHODS: Consecutive patients with OHT, POAG, NTG, and normal individuals were recruited. CCT was measured by ultrasonic pachymetry, whereas ST was measured using ultrasonic biomicroscopy at the temporal quadrant, 2'mm posterior to the scleral spur. Investigators were masked to the diagnosis and CCT/ ultrasonic biomicroscopy data. Correlation between mean CCT and ST was analyzed. RESULTS: One hundred and twenty-four subjects (31 with OHT, 31 with POAG, 31 with NTG, and 31 normal individuals) were enrolled. The CCT (OHT 548.06±30.45'µm; POAG 519.39±42.95'µm; NTG 505.81±27.23'µm; controls 529.90±43.40'µm) was found to be thicker in patients with OHT than POAG (P=0.004) or NTG (P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the quality of reporting of diagnostic accuracy studies using optical coherence tomography (OCT) in glaucoma. Design: Descriptive series of published studies. Participants: Published studies reporting a measure of the diagnostic accuracy of OCT for glaucoma. Methods: Review of English language papers reporting measures of diagnostic accuracy of OCT for glaucoma. Papers were identified from a Medline literature search performed in June 2006. Articles were appraised using the 25 items provided by the Standards for Reporting of Diagnostic Accuracy (STARD) initiative. Each item was recorded as full, partially, or not reported. Main Outcome Measures: Degree of compliance with the STARD guidelines. Results: Thirty papers were appraised. Eight papers (26.7%) fully reported more than half of the STARD items. The lowest number of fully reported items in a study was 5 and the highest was 17. Descriptions of key aspects of methodology frequently were missing. For example, details of participant sampling (e.g., consecutive or random selection) were described in only 8 (26.7%) of 30 publications. Measures of statistical uncertainty were reported in 18 (60%) of 30 publications. No single STARD item was fully reported by all the papers. Conclusions: The standard of reporting of diagnostic accuracy studies in glaucoma using OCT was suboptimal. It is hoped that adoption of the STARD guidelines will lead to an improvement in reporting of diagnostic accuracy studies, enabling clearer evidence to be produced for the usefulness of OCT for the diagnosis of glaucoma. © 2007 American Academy of Ophthalmology.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim - To evaluate the comparative efficacy and tolerance of latanoprost versus timolol through a meta-analysis of randomised controlled trials (RCTs). Methods - Systematic retrieval of RCTs of latanoprost versus timolol to allow pooling of results from head to head comparison studies. Quality of trials was assessed based on randomisation, masking, and withdrawal. Sensitivity analyses were used to estimate the effects of quality of study on outcomes. The data sources were Medline, Embase, Scientific Citation Index, Merck Glaucoma, and Pharmacia and Upjohn ophthalmology databases. There were 1256 patients with open angle glaucoma or ocular hypertension reported in 11 trials of latanoprost versus timolol. The main outcome measures were (i) percentage intraocular pressure (IOP) reduction for efficacy; (ii) relative risk, risk difference, and number needed to harm for side effects such as hyperaemia, conjunctivitis, increased pigmentation, hypotension, and bradycardia expressed as dichotomous outcomes; and (iii) reduction in systemic blood pressure and heart rate as side effects. Results - Both 0.005% latanoprost once daily and 0.5% timolol twice daily reduced IOP. The percentage reductions in IOP from baseline (mean (SE)) produced by latanoprost and timolol were 30.2 (2.3) and 26.9 (3.4) at 3 months. The difference in IOP reduction between the two treatments were 5.0 (95% confidence intervals 2.8, 7.3). However, latanoprost caused iris pigmentation in more patients than timolol (relative risk = 8.01, 95% confidence intervals 1.87, 34.30). The 2 year risk with latanoprost reached 18% (51/277). Hyperaemia was also more often observed with latanoprost (relative risk = 2.20, 95% confidence intervals 1.33, 3.64). Timolol caused a significant reduction in heart rate of 4 beats/minute (95% confidence interval 2, 6). Conclusion - This meta-analysis suggests that latanoprost is more effective than timolol in lowering IOP. However, it often causes iris pigmentation. While current evidence suggests that this pigmentation is benign, careful lifetime evaluation of patients is still justified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the changes in the Visual Field Index (VFI) in eyes with perimetric glaucomatous progression, and to compare these against stable glaucoma patients.

PATIENTS AND METHODS: Consecutive patients with open angle glaucoma with a minimum of 6 reliable visual fields and 2 years of follow-up were identified. Perimetric progression was assessed by 4 masked glaucoma experts from different units, and classified into 3 categories: "definite progression," "suspected progression," or "no progression." This was compared with the Glaucoma Progression Analysis (GPA) II and VFI linear regression analysis, where progression was defined as a negative slope with significance of <5%.

RESULTS: Three hundred ninety-seven visual fields from 51 eyes of 39 patients were assessed. The mean number of visual fields was 7.8 (SD 1.1) per eye, and the mean follow-up duration was 63.7 (SD 13.4) months. The mean VFI linear regression slope showed an overall statistically significant difference (P<0.001, analysis of variance) for each category of progression. Using expert consensus opinion as the reference standard, both VFI analysis and GPA II had high specificity (0.93 and 0.90, respectively), but relatively low sensitivity (0.45 and 0.41, respectively).

CONCLUSIONS: The mean VFI regression slope in our cohort of eyes without perimetric progression showed a statistically significant difference compared with those with suspected and definite progression. VFI analysis and GPA II both had similarly high specificity but low sensitivity when compared with expert consensus opinion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Glaucoma in infants has many causes. Evaluation of the anatomy of the anterior segment of eyes with infantile glaucoma may help to determine the pathogenesis of an infant's disease and influence therapeutic decisions. Methods: Eleven eyes of six infants with glaucoma were evaluated with ultrasound biomicroscopy (UBM) to evaluate the anatomic characteristics and relationships of the anterior segment structures. Results: The anterior chamber angle, iris, lens, ciliary body, and posterior chamber angle could be imaged in detail. Elongated and anteriorly placed ciliary processes were noted in all eight eyes with trabeculodysgenesis. There were no apparent anomalies in the trabecular meshwork, or anterior chamber. In three eyes with dense corneal opacities, ultrasound biomicroscopy showed severe anterior segment disorganization and thin central corneas with posterior corneal excavation. Conclusions: Ultrasound biomicroscopy is a useful non-invasive method for evaluating infants with glaucoma in cases with corneal opacities. This information can help in surgical planning for glaucoma management.