143 resultados para Insertion
Resumo:
In 1862, Glasgow Corporation initiated the first of a series of three legislative acts which would become known collectively as the City Improvements Acts. Despite having some influence on the nature of the built fabric on the expanding city as a whole, the most extensive consequences of these acts was reserved for one specific area of the city, the remnants of the medieval Old Town. As the city had expanded towards all points of the compass in a regular, grid-iron structure throughout the nineteenth century, the Old Town remained singularly as a densely wrought fabric of medieval wynds, vennels, oblique passageways and accelerated tenementalisation. Here, as the rest of the city began to assume the form of an ordered entity, visible and classifiable, one could still find and addresses such as ‘Bridgegate, No. 29, backland, stair first left, three up, right lobby, door facing’ (quoted in Pacione, 1995).
Unsurprisingly, this place, where proximity to the midden (dung-heap) was considered an enviable position, was seen by the authorities as a major health hazard and a source not only of cholera, but also of the more alarming typhoid epidemic of 1842. Accordingly, the demolitions which occurred in the backlands of the Old Town under the first of the acts, the Glasgow Police Act of 1862, were justified on health and medical grounds. But disease was not the only social problem thought to issue from this district. Reports from social reformers including Fredrick Engels suggested that the decay of the area’s physical fabric could be extended to the moral profile of its inhabitants. This was in such a state of degeneracy that there were calls for a nearby military barracks to be relocated to more salubrious climes because troops were routinely coming into contact ‘with the most dissolute and profligate portion of the population’ (Peter Clonston, Lord Provost, June 1861). Perhaps more worrying for the city fathers, however, was that the barracks’ arsenal was seen as a potential source of arms for the militant and often illegal cotton workers’ unions and organisations who inhabited the Old Town as well as the districts to the east. In fact, the Old Town and East End had been the site of numerous working class actions and riots since 1787, including a strike of 60,000 workers in 1820, 100,000 in 1838, and the so-called Bread Riots of 1848 where shouts of ‘Vive La Revolution’ were reported in the Gallowgate.
The events in Paris in 1848 precipitated Baron Hausmann’s interventions into that city. The boulevards were in turn visited by members of Glasgow Corporation and ultimately, it can be argued, provided an example for Old Town Glasgow. This paper suggests that the city improvement acts carried a similarly complex and pervasive agenda, one which embodied not only health, class conflict and sexual morality but also the more local condition of sectarianism. And, like in Paris, these were played out spatially in a extensive reconfiguration of the urban fabric of the Old Town which, through the creation of new streets and a railway yard, not only made it more amenable to large scale military manoeuvres but also, opened up the area to capitalist accumulation. By the end of the works, the medieval heritage of the Old Town had been almost completely razed, the working class and Catholic East End had, through the insertion of the railway yard, been isolated from the city centre and approximately 70,000 people had been made homeless.
Resumo:
BACKGROUND: This study aims to assess the quality of various steps of manual small incision cataract surgery and predictors of quality, using video recordings.
DESIGN: This paper applies a retrospective study.
PARTICIPANTS: Fifty-two trainees participated in a hands-on small incision cataract surgery training programme at rural Chinese hospitals.
METHODS: Trainees provided one video each recorded by a tripod-mounted digital recorder after completing a one-week theoretical course and hands-on training monitored by expert trainers. Videos were graded by two different experts, using a 4-point scale developed by the International Council of Ophthalmology for each of 12 surgical steps and six global factors. Grades ranged from 2 (worst) to 5 (best), with a score of 0 if the step was performed by trainers.
MAIN OUTCOME MEASURES: Mean score for the performance of each cataract surgical step rated by trainers.
RESULTS: Videos and data were available for 49/52 trainees (94.2%, median age 38 years, 16.3% women and 77.5% completing > 50 training cases). The majority (53.1%, 26/49) had performed ≤ 50 cataract surgeries prior to training. Kappa was 0.57∼0.98 for the steps (mean 0.85). Poorest-rated steps were draping the surgical field (mean ± standard deviation = 3.27 ± 0.78), hydro-dissection (3.88 ± 1.22) and wound closure (3.92 ± 1.03), and top-rated steps were insertion of viscoelastic (4.96 ± 0.20) and anterior chamber entry (4.69 ± 0.74). In linear regression models, higher total score was associated with younger age (P = 0.015) and having performed >50 independent manual small incision cases (P = 0.039).
CONCLUSIONS: More training should be given to preoperative draping, which is poorly performed and crucial in preventing infection. Surgical experience improves ratings.© 2015 Royal Australian and New Zealand College of Ophthalmologists.
Resumo:
OBJECTIVE:
To design a system of gonioscopy that will allow greater interobserver reliability and more clearly defined screening cutoffs for angle closure than current systems while being simple to teach and technologically appropriate for use in rural Asia, where the prevalence of angle-closure glaucoma is highest.
DESIGN:
Clinic-based validation and interobserver reliability trial.
PARTICIPANTS:
Study 1: 21 patients 18 years of age and older recruited from a university-based specialty glaucoma clinic; study 2: 32 patients 18 years of age and older recruited from the same clinic.
INTERVENTION:
In study 1, all participants underwent conventional gonioscopy by an experienced observer (GLS) using the Spaeth system and in the same eye also underwent Scheimpflug photography, ultrasonographic measurement of anterior chamber depth and axial length, automatic refraction, and biometric gonioscopy with measurement of the distance from iris insertion to Schwalbe's line using a reticule based in the slit-lamp ocular. In study 2, all participants underwent both conventional gonioscopy and biometric gonioscopy by an experienced gonioscopist (NGC) and a medical student with no previous training in gonioscopy (JK).
MAIN OUTCOME MEASURES:
Study 1: The association between biometric gonioscopy and conventional gonioscopy, Scheimpflug photography, and other factors known to correlate with the configuration of the angle. Study 2: Interobserver agreement using biometric gonioscopy compared to that obtained with conventional gonioscopy.
RESULTS:
In study 1, there was an independent, monotonic, statistically significant relationship between biometric gonioscopy and both Spaeth angle (P = 0.001, t test) and Spaeth insertion (P = 0.008, t test) grades. Biometric gonioscopy correctly identified six of six patients with occludable angles according to Spaeth criteria. Biometric gonioscopic grade was also significantly associated with the anterior chamber angle as measured by Scheimpflug photography (P = 0.005, t test). In study 2, the intraclass correlation coefficient between graders for biometric gonioscopy (0.97) was higher than for Spaeth angle grade (0.72) or Spaeth insertion grade (0.84).
CONCLUSION:
Biometric gonioscopy correlates well with other measures of the anterior chamber angle, shows a higher degree of interobserver reliability than conventional gonioscopy, and can readily be learned by an inexperienced observer.
Resumo:
AIM:
To utilise a novel method for making measurements in the anterior chamber in order to compare the anterior chamber angles of people of European, African, and east Asian descent aged 40 years and over.
METHODS:
A cross sectional study on 15 people of each sex from each decade from the 40s to the 70s, from each of three racial groups-black, white, and Chinese Singaporeans. Biometric gonioscopy (BG) utilises a slit lamp mounted reticule to make measurements from the apparent iris insertion to Schwalbe's line through a Goldmann one mirror goniolens. The main outcome measures were BG measurements of the anterior chamber angle as detailed above.
RESULTS:
There was no significant difference in angle measurement between black, white, and Chinese races in this study. However, at younger ages people of Chinese race appeared to have deeper angles than white or black people, whereas the angles of older Chinese were significantly narrower (p = 0.004 for the difference in slope of BG by age between Chinese and both black and white people).
CONCLUSION:
The failure to detect a difference in angle measurements between these groups was surprising, given the much higher prevalence of angle closure among Chinese. It appears that the overall apparent similarity of BG means between Chinese and Western populations may mask very different trends with age. The apparently more rapid decline in angle width measurements with age among Chinese may be due to the higher prevalence of cataract or "creeping angle closure." However, longitudinal inferences from cross sectional data are problematic, and this may represent a cohort phenomenon caused by the increasing prevalence of myopia in the younger Singaporean population.
Resumo:
We describe, for the first time, hydrogel-forming microneedle (MN) arrays for minimally-invasive extraction and quantification of lithium in vitro and in vivo. MN arrays, prepared from aqueous blends of hydrolysed poly(methyl-vinylether-co-maleic anhydride) and crosslinked by poly(ethyleneglycol), imbibed interstitial fluid (ISF) upon skin insertion. Such MN were always removed intact. In vitro, mean detected lithium concentrations showed no significant difference following 30 min MN application to excised neonatal porcine skin for lithium citrate concentrations of 0.9 and 2 mmol/l. However, after 1 h application, the mean lithium concentrations extracted were significantly different, being appropriately concentration-dependent. In vivo, rats were orally dosed with lithium citrate equivalent to 15 mg/kg and 30 mg/kg lithium carbonate, respectively. MN arrays were applied 1 h after dosing and removed 1 h later. The two groups, having received different doses, showed no significant difference between lithium concentrations in serum or MN. However, the higher dosed rats demonstrated a lithium concentration extracted from MN arrays equivalent to a mean increase of 22.5 % compared to rats which received the lower dose. Hydrogel-forming MN clearly have potential as a minimally-invasive tool for lithium monitoring in out-patient settings. We will now focus on correlation of serum and MN lithium concentrations.
Resumo:
This paper describes the design of a frequency selective surface (FSS) which provides transmission of 228 - 230 GHz radiation and rejection from 164 – 191.3 GHz with insertion losses under 0.25 dB for TE wave polarization at 45 incidence. This state-of-the art filter consists of two air spaced freestanding perforated screens, comprising unit cell elements of resonant slots folded for the purpose of miniaturisation to enhance angular stability. The reported geometry enhances the angular stability (45 ± 10) of the FSS beyond what is possible with canonical linear slots and satisfies the stringent electromagnetic performance requirements for signal demultiplexing in the quasi-optical feed train of the Microwave Sounder (MWS) instrument.
Resumo:
A new heuristic based on Nawaz–Enscore–Ham (NEH) algorithm is proposed for solving permutation flowshop scheduling problem in this paper. A new priority rule is proposed by accounting for the average, mean absolute deviation, skewness and kurtosis, in order to fully describe the distribution style of processing times. A new tie-breaking rule is also introduced for achieving effective job insertion for the objective of minimizing both makespan and machine idle-time. Statistical tests illustrate better solution quality of the proposed algorithm, comparing to existing benchmark heuristics.
Resumo:
Side channel attacks permit the recovery of the secret key held within a cryptographic device. This paper presents a new EM attack in the frequency domain, using a power spectral density analysis that permits the use of variable spectral window widths for each trace of the data set and demonstrates how this attack can therefore overcome both inter-and intra-round random insertion type countermeasures. We also propose a novel re-alignment method exploiting the minimal power markers exhibited by electromagnetic emanations. The technique can be used for the extraction and re-alignment of round data in the time domain.