180 resultados para Fluorescence polarization immunoassay (FPIA)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Diabetes Control and Complications Trial (DCCT)/Epidemiology of Diabetes Interventions and Complications(EDIC) studies have established multiyear mean hemoglobin A1c (HbA1c) as predictive of microvascular complications in persons with type 1 diabetes. However, multiyear mean HbA1c is not always available in the clinical setting. Skin advanced glycation end products (AGEs) are thought to partially reflect effects of hyperglycemia over time, and measurement of skin AGEs might be a surrogate for multiyear mean HbA1c. As certain AGEs fluoresce and skin fluorescence has been demonstrated to correlate with the concentration of skin AGEs, noninvasive measurement by skin intrinsic fluorescence(SIF) facilitates the exploration of the association of mean HbA1c and other clinical/technical factors with SIF using the detailed phenotypic database available in DCCT/EDIC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVESTo determine whether skin-intrinsic fluorescence (SIF) is associated with long-term complications of type 1 diabetes (T1D) and, if so, whether it is independent of chronic glycemic exposure and previous intensive therapy.RESEARCH DESIGN AND METHODSWe studied 1,185 (92%) of 1,289 active Diabetes Control and Complications Trial (DCCT)/Epidemiology of Diabetes Interventions and Complications (EDIC) participants from 2010 to 2011. SIF was determined using a fluorescence spectrometer and related cross-sectionally to recently determined measures of retinopathy (stereo fundus photography), cardiac autonomic neuropathy (CAN; R-R interval), confirmed clinical neuropathy, nephropathy (albumin excretion rate [AER]), and coronary artery calcification (CAC).RESULTSOverall, moderately strong associations were seen with all complications, before adjustment for mean HbA1c over time, which rendered these associations nonsignificant with the exception of sustained AER >30 mg/24 h and CAC, which were largely unaffected by adjustment. However, when examined within the former DCCT treatment group, associations were generally weaker in the intensive group and nonsignificant after adjustment, while in the conventional group, associations remained significant for CAN, sustained AER >30 mg/24 h, and CAC even after mean HbA1c adjustment.CONCLUSIONSSIF is associated with T1D complications in DCCT\EDIC. Much of this association appears to be related to historical glycemic exposure, particularly in the previously intensively treated participants, in whom adjustment for HbA1c eliminates statistical significance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional approaches of digital modulation schemes make use of amplitude, frequency and/or phase as modulation characteristic to transmit data. In this paper, we exploit circular polarization (CP) of the propagating electromagnetic carrier as modulation attribute which is a novel concept in digital communications. The requirement of antenna alignment to maximize received power is eliminated for CP signals and these are not affected by linearly polarized jamming signals. The work presents the concept of Circular Polarization Modulation for 2, 4 and 8 states of carrier and refers them as binary circular polarization modulation (BCPM), quaternary circular polarization modulation (QCPM) and 8-state circular polarization modulation (8CPM) respectively. Issues of modulation, demodulation, 3D symbol constellations and 3D propagating waveforms for the proposed modulation schemes are presented and analyzed in the presence of channel effects, and they are shown to have the same bit error performance in the presence of AWGN compared with conventional schemes while provide 3dB gain in the flat Rayleigh fading channel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diazacoronand 2 undergoes drastic conformational switching upon binding sodium ions as demonstrated by solution- and solid-state studies, which permit the design of efficient fluorescent PET (photoinduced electron transfer) switches 3a,b.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coccidiostats are authorized in the European Union (EU) to be used as poultry feed additives. Maximum (residue) levels (M(R)Ls) have been set within the EU for consumer and animal protection against unintended carry-over, and monitoring is compulsory. This paper describes the single-laboratory validation of a previously developed multiplex flow cytometric immunoassay (FCIA) as screening method for coccidiostats in eggs and feed and provides and compares different approaches for the calculation of the cut-off levels which are not described in detail within Commission Decision 2002/657/EC. Comparable results were obtained between the statistical (reference) approach and the rapid approaches. With the most rapid approach, the cut-off levels for narasin/salinomycin, lasalocid, diclazuril, nicarbazin (DNC) and monensin in egg, calculated as percentages of inhibition (%B/B0), were 60, 32, 76, 80 and 84, respectively. In feed, the cut-off levels for narasin/salinomycin, lasalocid, nicarbazin (DNC) and monensin were 70, 64, 72 and 78, respectively, and could not be determined for diclazuril. For all analytes, except for diclazuril in feed, the rate of false positives (false non-compliant) in blank samples was lower than 1 %, and the rate of false negatives (false compliant) at the M(R)Ls was below 5 %. Additionally, very good correlations (r ranging from 0.994 to 0.9994) were observed between two different analysers, a sophisticated flow cytometer (FlexMAP 3D(®)) and a more cost-efficient and transportable planar imaging detector (MAGPIX(®)), hence demonstrating adequate transferability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A lateral flow immunoassay (LFIA) has been developed and fully validated to detect the primary amnesic shellfish poisoning (ASP) toxin, domoic acid (DA). The performance characteristics of two versions of the test were investigated using spiked and naturally contaminated shellfish (mussels, scallops, oysters, clams, and cockles). The tests provide a qualitative result, to indicate the absence or presence of DA in extracts of shellfish tissues, at concentrations that are relevant to regulatory limits. The new rapid assay (LFIA version 2) was designed to overcome the performance limitations identified in the first version of the assay. The improved test uses an electronic reader to remove the subjective nature of the generated results, and the positive cut-off for screening of DA in shellfish was increased from 10 ppm (version 1) to 17.5 ppm (version 2). A simple extraction and test procedure was employed, which required minimal equipment and materials; results were available 15 min after sample preparation. Stability of the aqueous extracts at room temperature (22 C) at four time points (up to 245 min after extraction) and across a range of DA concentrations was 100.3±1.3% and 98.8±2.4% for pre- and post-buffered extracts, respectively. The assay can be used both within laboratory settings and in remote locations. The accuracy of the new assay, to indicate negative results at or below 10 ppm DA, and positive results at or above 17.5 ppm, was 99.5% (n=216 tests). Validation data were obtained from a 2-day, randomised, blind study consisting of multiple LFIA lots (n=3), readers (n=3) and operators (n=3), carrying out multiple extractions of mussel tissue (n=3) at each concentration (0, 10, 17.5, and 20 ppm). No matrix effects were observed on the performance of the assay with different species (mussels, scallops, oysters, clams, and cockles). There was no impact on accuracy or interference from other phycotoxins, glutamic acid or glutamine with various strip incubations (8, 10, and 12 min). The accuracy of the assay, using naturally contaminated samples to indicate negative results at or below 12.5 ppm and positive results at or above 17.5 ppm, was 100%. Variability between three LFIA lots across a range of DA concentrations, expressed as coefficient of variation (% CV), was 1.1±0.4% (n=2 days) based on quantitative readings from the electronic reader. During an 8 week stability study, accuracy of the method with test strips stored at various temperatures (6, 22, 37 and 50 C) was 100%. Validation for both versions included comparisons with results obtained using reference LC-UV methods. © 2013 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The change in the Pt electronic structure following the adsorption of an a,ß-unsaturated aldehyde and ketone was followed by in situ HERFD-XANES in the liquid phase. The resulting shift in the Pt Fermi energy is in good agreement with the molecule adsorption energy trends calculated by DFT and provides insight into the reaction selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapid and robust methods are required to quantify the effect of hydrodynamic shear on protein conformation change. We evaluated such strategies in this work and found that the binding of the fluorescent probe 4,4'-dianilino-1, 1'-binaphthyl-5,5'-disulfonic acid (bis-ANS) to hydrophobic pockets in the blood protein von Willebrand factor (VWF) is enhanced upon the application of fluid shear to the isolated protein. Significant structural changes were observed when the protein was sheared at shear rates >= 6000/s for similar to 3.5 min. The binding of bis-ANS to multimeric VWF, but not dimeric VWF or control protein bovine serum albumin, was enhanced upon fluid shear application. Thus, high-molecular-weight VWF is more susceptible to conformation change upon tensile loading. Although bis-ANS itself did not alter the conformation of VWF, it stabilized protein conformation once it bound the sheared molecule. Bis-ANS binding to VWF was reduced when the sheared protein was allowed to relax before dye addition. Taken together with functional data in the literature, our results suggest that shear-induced conformation changes in VWF reported by bis-ANS correlate well with the normal function of the protein under physiological/pathological fluid flow conditions. Further, this study introduces the fluorescent dye bis-ANS as a tool that may be useful in studies of shear-induced protein conformation change.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design, development and evaluation of an optical fibre pH sensor for monitoring pH in the alkaline region are discussed in detail in this paper. The design of this specific pH sensor is based on the pH induced change in fluorescence intensity of a coumarin imidazole dye which is covalently attached to a polymer network and then fixed to the distal end of an optical fibre. The sensor provides a response over a pH range of 10.0–13.2 with an acceptable response rate of around 50 min, having shown a very good stability over a period of longer than 20 months thus far. The sensor has also demonstrated little cross-sensitivity to ionic strength (IS) and also excellent photostability through a series of laboratory tests. These features make this type of sensor potentially well suited for in situ long term monitoring of pH in concrete structures, to enhance structural monitoring in the civil engineering sector

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An electronically tunable reflection polarizer which exploits the dielectric anisotropy of nematic liquid crystals (LC) has been designed, fabricated and measured in a frequency band centered at 130 GHz. The phase agile polarizing mirror converts an incident slant 45° signal upon reflection to right hand circular (RHCP), orthogonal linear (-45 °) or left hand circular (LHCP) polarization depending on the value of the voltage biasing the LC mixture. In the experimental set-up this is achieved by applying a low frequency bias voltage of 0 V, 40 V and 89 V respectively, across the cavity containing the LC material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A frequency selective surface (FSS) which can be utilized as a diplexer for circular polarization (CP) applications is proposed. The structure consists of two dipole-based FSS placed parallel to each other. The dipoles in one array are rotated by 90° with respect to those in the other. For an angle of incidence of 45° at one frequency band the structure allows a CP signal to be transmitted while at a further band it converts a linearly polarized (LP) signal to CP upon reflection. Full-wave simulation results validated the concept.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We address the propagation of a single photon pulse with two polarization components, i.e., a polarization qubit, in an inhomogeneously broadened "phaseonium" \Lambda-type three-level medium. We combine some of the non-trivial propagation effects characteristic for this kind of coherently prepared systems and the controlled reversible inhomogeneous broadening technique to propose several quantum information processing applications, such as a protocol for polarization qubit filtering and sieving as well as a tunable polarization beam splitter. Moreover, we show that, by imposing a spatial variation of the atomic coherence phase, an effcient quantum memory for the incident polarization qubit can be also implemented in \Lambda-type three-level systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate an optical quantum memory scheme with V-type three-level atoms based on the controlled reversible inhomogeneous broadening (CRIB) technique. We theoretically show the possibility to store and retrieve a weak light pulse interacting with the two optical transitions of the system. This scheme implements a quantum memory for a polarization qubit - a single photon in an arbitrary polarization state - without the need of two spatially separated two-level media, thus offering the advantage of experimental compactness overcoming the limitations due to mismatching and unequal efficiencies that can arise in spatially separated memories. The effects of a relative phase change between the atomic levels, as well as of phase noise due to, for example, the presence of spurious electric and magnetic fields are analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Animals can call on a multitude of sensory information to orient and navigate. In some cases they may calibrate these cues against each other to establish the most accurate information available. One such cue is the pattern of polarized light in the sky, which may be used as a geographical reference to calibrate other cues in the compass mechanism. Mammals, however, have not been shown to use this cue, even though they do calibrate a magnetic compass with sunset. In this paper we demonstrate that bats use polarization cues at sunset to calibrate a magnetic compass, subsequently used for orientation during a homing experiment. It is thus the only mammal known so far to make use of the polarization pattern in the sky. This is an intriguing finding as currently there is no clear understanding of how this cue is perceived in this taxon and has general implications for the sensory biology of mammalian vision.