Since the first launch of the new engineering contract (NEC) in 1993, early warning of problems has been widely recognized as an important approach of proactive management during a construction or engineering project. Is early warning really effective for the improvement of problem solving and project performance? This is a research question that still lacks a good answer. For this reason, an empirical investigation was made in the United Kingdom (U.K.) to answer the question. This study adopts a combination of literature review, expert interview, and questionnaire survey. Nearly 100 questionnaire responses were collected from the U.K. construction industry, based on which the use of early warning under different forms of contract is compared in this paper. Problem solving and project performance are further compared between the projects using early warning and the projects not using early warning. The comparison provides clear evidence for the significant effect of early warning on problem solving and project performance in terms of time, cost, and quality. Subsequently, an input-process-output model is developed in this paper to explore the relationship among early warning, problem solving, and project
performance. All these help construction researchers and practitioners to better understand the role of early warning in ensuring project success.
Resumo:
Spin chains are promising media for short-haul quantum communication. Their usefulness is manifested in all those situations where stationary information carriers are involved. In the majority of the communication schemes relying on quantum spin chains, the latter are assumed to be finite in length, with well-addressable end-chain spins. In this paper we propose that such a configuration could actually be achieved by a mechanism that is able to effectively cut a spin ring through the insertion of bond defects. We then show how suitable physical quantities can be identified as figures of merit for the effectiveness of the cut. We find that, even for modest strengths of the bond defect, a ring is effectively cut at the defect site. In turn, this has important effects on the amount of correlations shared by the spins across the resulting chain, which we study by means of a scattering-based mechanism of a clear physical interpretation. © 2013 American Physical Society.
Resumo:
Introduction: Immediate reconstruction following mastectomy for breast cancer has been shown to be oncologically safe and associated with improved psychosocial outcomes for patients. Bostwick described a technique for one-stage implant based reconstruction, combining skin-sparing mastectomy with concurrent reduction of the skin envelope. This report reviews the experience of a single centre using skin-reducing mastectomy and one-stage implant reconstruction in both early stage breast cancer and risk-reducing mastectomy, with specific reference to frequency of complications, implant loss and oncological outcomes.
Methods and results: A retrospective review was undertaken to identify women who had undergone skin-reducing mastectomy and one-stage implant reconstruction using a de-epithelialised dermal flap, between October 2008 and October 2012. One hundred and four consecutive mastectomies, with reconstruction, were performed by two surgeons on 64 patients. No complications were seen in 43.8% of patients. At three months, four implants were lost (3.8% of breast reconstructions, 6.3% of patients), due to either peri-implant infection or mastectomy skin flap necrosis. One patient required unplanned return to theatre for evacuation of a haematoma. Minor mastectomy skin flap necrosis was seen in 10 breasts (9.6% of reconstructed breasts) and superficial wound infection in 8 breasts (7.7% of reconstructed breasts). All of these complications were managed conservatively and none required operative intervention. At a median follow up of 35 months (4-53 months) there had been one episode of ipsilateral axillary nodal recurrence.
Conclusion: One-stage implant reconstruction using a myo-dermal flap technique following skin-reducing mastectomy is safe and should be considered in selected patients. Most complications are minor and will resolve with conservative management. Major complications such as implant failure or immediate reoperation, were relatively uncommon (6.3% patients, 3.8% of reconstructed breasts). Early follow-up suggests that oncological outcomes are satisfactory, but longer follow-up is required to substantiate this. (C) 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Resumo:
The exponential growth in user and application data entails new means for providing fault tolerance and protection against data loss. High Performance Com- puting (HPC) storage systems, which are at the forefront of handling the data del- uge, typically employ hardware RAID at the backend. However, such solutions are costly, do not ensure end-to-end data integrity, and can become a bottleneck during data reconstruction. In this paper, we design an innovative solution to achieve a flex- ible, fault-tolerant, and high-performance RAID-6 solution for a parallel file system (PFS). Our system utilizes low-cost, strategically placed GPUs — both on the client and server sides — to accelerate parity computation. In contrast to hardware-based approaches, we provide full control over the size, length and location of a RAID array on a per file basis, end-to-end data integrity checking, and parallelization of RAID array reconstruction. We have deployed our system in conjunction with the widely-used Lustre PFS, and show that our approach is feasible and imposes ac- ceptable overhead.
Resumo:
Context. Absorption or emission lines of Fe II are observed in many astrophysical spectra and accurate atomic data are required to interpret these lines. The calculation of electron-impact excitation rates for transitions among even the lowest lying levels of Fe II is a formidable task for theoreticians.
Aims. In this paper, we present collision strengths and effective collision strengths for electron-impact excitation of Fe II for low-lying forbidden transitions among the lowest 16 fine-structure levels arising from the four LS states 3d(6)4s D-6(e), 3d(7) F-4(e), 3d(6)4s D-4(e), and 3d(7) P-4(e). The effective collision strengths are calculated for a wide range of electron temperatures of astrophysical importance from 30-100 000 K.
Methods. The parallel suite of Breit-Pauli codes are utilised to compute the collision cross sections for electron-impact excitation of Fe II and relativistic terms are included explicitly in both the target and the scattering approximation. 100 LS or 262-jj levels formed from the basis configurations 3d(6)4s, 3d(7), and 3d(6)4p were included in the wavefunction representation of the target, including all doublet, quartet, and sextet terms. Collision strengths for a total of 34191 individual transitions were computed.
Results. A detailed comparison is made with previous theoretical works and significant differences were found to occur in the effective collision strengths, particularly at low temperatures.
ARTICLE: No Effective Trafficking Definition Exists: Domestic Implementation of the Palermo Protocol
Medically unexplained symptoms: The need for effective communication and an integrated care strategy
Resumo:
Much is already known about medically unexplained symptoms (MUS) in terms of incidence, presentation and current treatment. What needs to be urgently addressed is a strategy for dealing with patients and their conditions, particularly when they do not fall neatly into medical frameworks or pathologies where the syndrome can be easily explained. This article will consider the provision of health and social care support for patients with MUS within an interprofessional education context. The author will contend that a sensitive and valued service for this large client group is dependent upon services without professional boundaries and practitioners with a clinical interest that can work together and agree an appropriate way forward in terms of care, support and strategic service provision. The article will support the idea that clear guidelines through the National Institute for Health and Care Excellence can offer clear clinical direction for practitioners working in primary and secondary care settings to work together interprofessionally to ensure a seamless and sensitive service for people with this condition.
Resumo:
Purpose: We reviewed the outcome of cuff downsizing with an artificial urinary sphincter for treating recurrent incontinence due to urethral atrophy.
Materials and Methods: We analyzed the records of 17 patients in a 7-year period in whom clinical, radiological and urodynamic evidence of urethral atrophy was treated with cuff downsizing. Cuff downsizing was accomplished by removing the existing cuff and replacing it with a 4 cm. cuff within the established false capsule. Incontinence and satisfaction parameters before and after the procedure were assessed by a validated questionnaire.
Results: Mean patient age was 70 years (range 62 to 79). Average time to urethral atrophy was 31 months (range 5 to 96) after primary sphincter implantation. Mean followup after downsizing was 22 months (range 1 to 64). Cuff downsizing caused a mean decrease of 3.9 to 0.5 pads daily. The number of severe leakage episodes decreased from a mean of 5.4 to 2.1 The mean SEAPI (stress leakage, emptying, anatomy, protection, inhibition) score decreased from 8.2 to 2.4. Patient satisfaction increased from 15% to 80% after cuff downsizing. In 1 patient an infected cuff required complete removal of the device.
Conclusions: Patient satisfaction and continence parameters improved after cuff downsizing. We believe that this technique is a simple and effective method of restoring continence after urethral atrophy.
Resumo:
Patients with intractably diminished bladder storage function are encountered frequently by neurourologists, occasionally requiring reconstructive surgery for appropriate resolution. Although sacral neuromodulation is a recognized effective therapeutic modality, present techniques are technically demanding, invasive, and expensive. This study investigated the effect of non-invasive third sacral nerve (S3) stimulation on bladder activity during filling cystometry. One hundred forty-six patients underwent standard urodynamic filling cystometry that was then immediately repeated. Patients in the study group (n = 74) received antidromic transcutaneous sacral neurostimulation during the second fill and the control group (n = 72) underwent a second fill without neurostimulation. A statistically significant increase in bladder storage capacity without a corresponding rise in detrusor pressure was observed in the neurostimulated patients. This improvement in functional capacity is an encouraging finding that further supports the use of this non-invasive treatment modality in clinical practice. Neurourol. Urodynam. 20:73-84. 2001. (C) 2001 Wiley-Liss, Inc.