145 resultados para Coupled oscillator
Resumo:
The ground state potential energy surface for CO chemisorption across Pd{110} has been calculated using density functional theory with gradient corrections at monolayer coverage. The most stable site corresponds well with the experimental adsorption heat, and it is found that the strength of binding to sites is in the following order: pseudo-short-bridge>atop>long-bridge>hollow. Pathways and transition states for CO surface diffusion, involving a correlation between translation and orientation, are proposed and discussed. (C) 1997 American Institute of Physics.
Resumo:
Traditional Chinese Medicines (TCMs) derived from animal horns are one of the most important types of Chinese medicine. In the present study, a fast and sensitive analytical method was established for qualitative and quantitative determination of 14 nucleosides and nucleobases in animal horns using hydrophilic interaction ultra-high performance liquid chromatography coupled with triple-quadruple tandem mass spectrometry (HILIC-UPLC-QQQ-MS/MS) in selective reaction monitoring (SRM) mode. The method was optimized and validated, and showed good linearity, precision, repeatability, and accuracy. The method was successfully used to determine contents of the 14 nucleosides and nucleobases in 25 animal horn samples. Hierarchical clustering analysis (HCA) and principal component analysis (PCA) were performed and the 25 samples were thereby divided into two groups, which agreed with taxonomy. The method may enable quick and effective search of substitutes for precious horns.
Resumo:
The electron dynamics in a planar coil inductively coupled plasma (ICP) system with a capacitively biased electrode is investigated using space and phase resolved optical emission spectroscopy. The two power source frequencies are exact multiple of each other and phase-locked. In this configuration, the system is investigated when the coil is operated in both E-mode and H-mode. The results show that in a phase synchronized RF biased ICP, the electrode bias power couples with the capacitive contribution of the coil, in both E-mode and H-modes, similar to dual-frequency capacitively coupled plasmas (2f-CCPs). It is also demonstrated that in H-mode, the phase between the electrode bias frequency and the ICP coil frequency influences the electron heating, similar to the electrical asymmetry effect in 2f-CCPs.
Resumo:
A simple circuit that is able to indicate if an injection-locked oscillator is in the locked condition by providing a ‘high’ or ‘low’ output is presented. The detector is compatible with most injection-locked oscillators as all that is required is access to the low-frequency bias circuit, with no direct access needed to the RF/microwave signals. To prove the universal nature of the lock detector it is successfully demonstrated practically for two scenarios: (i) a 1 GHz injection-locked VCO and (ii) a 60 GHz SiGe VCO MMIC.
Resumo:
How can we correlate neural activity in the human brain as it responds to words, with behavioral data expressed as answers to questions about these same words? In short, we want to find latent variables, that explain both the brain activity, as well as the behavioral responses. We show that this is an instance of the Coupled Matrix-Tensor Factorization (CMTF) problem. We propose Scoup-SMT, a novel, fast, and parallel algorithm that solves the CMTF problem and produces a sparse latent low-rank subspace of the data. In our experiments, we find that Scoup-SMT is 50-100 times faster than a state-of-the-art algorithm for CMTF, along with a 5 fold increase in sparsity. Moreover, we extend Scoup-SMT to handle missing data without degradation of performance. We apply Scoup-SMT to BrainQ, a dataset consisting of a (nouns, brain voxels, human subjects) tensor and a (nouns, properties) matrix, with coupling along the nouns dimension. Scoup-SMT is able to find meaningful latent variables, as well as to predict brain activity with competitive accuracy. Finally, we demonstrate the generality of Scoup-SMT, by applying it on a Facebook dataset (users, friends, wall-postings); there, Scoup-SMT spots spammer-like anomalies.
Resumo:
We present a comprehensive model for predicting the full performance of a second harmonic generation-optical parametric amplification system that aims at enhancing the temporal contrast of laser pulses. The model simultaneously takes into account all the main parameters at play in the system such as the group velocity mismatch, the beam divergence, the spectral content, the pump depletion, and the length of the nonlinear crystals. We monitor the influence of the initial parameters of the input pulse and the interdependence of the two related non-linear processes on the performance of the system and show its optimum configuration. The influence of the initial beam divergence on the spectral and the temporal characteristics of the generated pulse is discussed. In addition, we show that using a crystal slightly longer than the optimum length and introducing small delay between the seed and the pump ensures maximum efficiency and compensates for the spectral shift in the optical parametric amplification stage in case of chirped input pulse. As an example, calculations for bandwidth transform limited and chirped pulses of sub-picosecond duration in beta barium borate crystal are presented.
Resumo:
Ligands targeting G protein-coupled receptors (GPCRs) are currently classified as either orthosteric, allosteric, or dualsteric/bitopic. Here, we introduce a new pharmacological concept for GPCR functional modulation: sequential receptor activation. A hallmark feature of this is a stepwise ligand binding mode with transient activation of a first receptor site followed by sustained activation of a second topographically distinct site. We identify 4-CMTB (2-(4-chlorophenyl)-3-methyl-N-(thiazol-2-yl)butanamide), previously classified as a pure allosteric agonist of the free fatty acid receptor 2, as the first sequential activator and corroborate its two-step activation in living cells by tracking integrated responses with innovative label-free biosensors that visualize multiple signaling inputs in real time. We validate this unique pharmacology with traditional cellular readouts, including mutational and pharmacological perturbations along with computational methods, and propose a kinetic model applicable to the analysis of sequential receptor activation. We envision this form of dynamic agonism as a common principle of nature to spatiotemporally encode cellular information.