178 resultados para objective tests


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abstract This study evaluates the reliability of self-assessment as a measure of computer competence. This evaluation is carried out in response to recent research which has employed self-reported ratings as the sole indicator of students’ computer competence. To evaluate the reliability of self-assessed computer competence, the scores achieved by students in self-assessed computer competence tests are compared with scores achieved in objective tests. The results reveal a statistically significantly over-estimation of computer competence among the students surveyed. Furthermore, reported pre-university computer experience in terms of home and school use and formal IT education does not affect this result. The findings call into question the validity of using self-assessment as a measure of computer competence. More generally, the study also provides an up-to-date picture of self-reported computer usage and IT experience among pre-university students from New Zealand and South-east Asia and contrasts these findings with those from previous research.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: The majority of women (71%) who undergo BRCA1/2 testing—designed to identify genetic mutations associated with increased risk of cancer—receive results that are termed ‘ambiguous’ or ‘uninformative negative’. How women interpret these results and the association with numerical ability was examined. Methods: In this study, 477 women at increased risk for breast and ovarian cancer were recruited via the Cancer Genetics Network. They were presented with information about the four different possible BRCA1/2 test results—positive, true negative, ambiguous and uninformative negative—and asked to indicate which of six options represents the best response. Participants were then asked which treatment options they thought a woman receiving the results should discuss with her doctor. Finally, participants completed measures of objective and subjective numeracy. Results: Almost all of the participants correctly interpreted the positive and negative BRCA1/2 genetic test results. However, they encountered difficulties interpreting the uninformative and ambiguous BRCA1/2 genetic test results. Participants were almost equally likely to think either that the woman had learned nothing from the test result or that she was as likely to develop cancer as the average woman. Highly numerate participants were more likely to correctly interpret inconclusive test results (ambiguous, OR = 1.62; 95% CI [1.28, 2.07]; p < 0.001; uninformative, OR = 1.40; 95% CI [1.10, 1.80]). Discussion: Given the medical and psychological ramifications of genetic testing, healthcare professionals should consider devoting extra effort to ensuring proper comprehension of ambiguous and uninformative negative test results by women. Copyright © 2014 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To determine whether optical aberrations caused by cataract can be detected and quantified objectively using a newly described focus detection system (FDS). SETTING: The Wilmer Opthalmological Institute, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. METHODS: The FDS uses a bull's eye photodetector to measure the double-pass blur produced from a point source of light. To determine the range and level of focus, signals are measured with a series of trial lenses in the light path selected to span the point of best focus to generate focus curves. The best corrected visual acuity (BCVA), refractive error, lens photograph grades, and FDS signals were obtained in 18 patients scheduled to have cataract surgery. The tests were repeated 6 weeks after surgery. RESULTS: The mean FDS outcome measures improved after cataract surgery, with increased peak height (P=.001) and decreased peak width (P=.001). Improvement in signal strength (integral of signal within +/-1.5 diopters of the point of best focus) strongly correlated with improvement in peak height (R(2)=.88, P<.0001) and photographic cataract grade (R(2)=.72, P<.0001). The mean BCVA improved from 20/50 to 20/26 (P<.0001). The improvement in BCVA correlated more closely with FDS signal strength (R(2)=.44, P=.001) than with cataract grade (R(2)=.25, P=.06). CONCLUSIONS: Improvement in FDS outcome measures correlated with cataract severity and improvement in visual acuity. This objective approach may be useful in long-term studies of cataract progression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently there has been an increasing interest in the development of new methods using Pareto optimality to deal with multi-objective criteria (for example, accuracy and architectural complexity). Once one has learned a model based on their devised method, the problem is then how to compare it with the state of art. In machine learning, algorithms are typically evaluated by comparing their performance on different data sets by means of statistical tests. Unfortunately, the standard tests used for this purpose are not able to jointly consider performance measures. The aim of this paper is to resolve this issue by developing statistical procedures that are able to account for multiple competing measures at the same time. In particular, we develop two tests: a frequentist procedure based on the generalized likelihood-ratio test and a Bayesian procedure based on a multinomial-Dirichlet conjugate model. We further extend them by discovering conditional independences among measures to reduce the number of parameter of such models, as usually the number of studied cases is very reduced in such comparisons. Real data from a comparison among general purpose classifiers is used to show a practical application of our tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atherosclerosis has an inflammatory basis, with cytokines, cellular adhesion molecules and pro-inflammatory cells having important roles in the initiation and progression of this process. Interleukin (IL) 6, IL-10 and transforming growth factor (TGF) β have been proposed as important modulators of the atherosclerotic process, with IL-6 having a pro-inflammatory, atherogenic effect and IL-10 and TGF-β having anti-inflammatory, protective roles. The possible role of functional polymorphisms in the promoter regions of the IL-6, IL-10 and TGF-β genes in the susceptibility to ischaemic heart disease (IHD) was investigated in a well-defined Irish population using two recently described family-based tests of association. We genotyped 1,012 individuals from 386 families with at least one member prematurely affected with IHD. Using the combined transmission disequilibrium test (TDT)/sib-TDT and the pedigree disequilibrium test, no association between any of the IL-6 -174G/C, IL-10 -1082G/A and TGF-β -509C/T polymorphisms and IHD was found. Our data demonstrate that, in an Irish population, these polymorphisms are not associated with IHD. © Springer-Verlag 2004.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sequential biological permeable reactive barrier (PRB) was determined to be the best option for remediating groundwater that has become contaminated with a wide range of organic contaminants (i.e., benzene, toluene, ethylbenzene, xylene and polyaromatic hydrocarbons), heavy metals (i.e., lead and arsenic), and cyanide at a former manufactured gas plant after 150 years of operation in Portadown, Northern Ireland. The objective of this study was to develop a modified flyash that could be used in the initial cell within a sequential biological PRB to filter complex contaminated groundwater containing ammonium. Flyash modified with lime (CaOH) and alum was subjected to a series of batch tests which investigated the modified cation exchange capacity (CEC) and rate of removal of anions and cations from the solution. These tests showed that a high flyash composition medium (80%) could remove 8.65 mol of ammonium contaminant for every kilogram of medium. The modified CEC procedure ruled out the possibility of cation exchange as the major removal mechanism. The medium could also adsorb anions as well as cations (i.e., Pb and Cr), but not with the same capacity. The initial mechanism for Pb and Cr removal is probably precipitation. This is followed by sorption, which is possibly the only mechanism for the removal of dichromate anions. Scanning electron microscopic analysis revealed very small (