39 resultados para data acquisition


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Double beam modulation is widely used in atomic collision experiments in the case where the noise arising froth each of the beams exceeds the measured signal. A method for minimizing the statistical uncertainty in a measured signal in a given time period is discussed, and a flexible modulation and counting system based on a low cost PIC microcontroller is described. This device is capable of modifying the acquisition parameters in real time during the course of an experimental run. It is shown that typical savings in data acquisition time of approximately 30% can be achieved using this optimized modulation scheme.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The introduction of functional data into the radiotherapy treatment planning process is currently the focus of significant commercial, technical, scientific and clinical development. The potential of such data from positron emission tomography (PET) was recognized at an early stage and was integrated into the radiotherapy treatment planning process through the use of image fusion software. The combination of PET and CT in a single system (PET/CT) to form an inherently fused anatomical and functional dataset has provided an imaging modality which could be used as the prime tool in the delineation of tumour volumes and the preparation of patient treatment plans, especially when integrated with virtual simulation. PET imaging typically using F-Fluorodeoxyglucose (F-FDG) can provide data on metabolically active tumour volumes. These functional data have the potential to modify treatment volumes and to guide treatment delivery to cells with particular metabolic characteristics. This paper reviews the current status of the integration of PET and PET/CT data into the radiotherapy treatment process. Consideration is given to the requirements of PET/CT data acquisition with reference to patient positioning aids and the limitations imposed by the PET/CT system. It also reviews the approaches being taken to the definition of functional/ tumour volumes and the mechanisms available to measure and include physiological motion into the imaging process. The use of PET data must be based upon a clear understanding of the interpretation and limitations of the functional signal. Protocols for the implementation of this development remain to be defined, and outcomes data based upon clinical trials are still awaited. © 2006 The British Institute of Radiology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A self-tuning filter is disclosed. The self-tuning filter includes a digital clocking signal and an input coupled to the digital clocking signal, whereby the input reads a value incident on the input when the digital clocking signal changes to a predetermined state. A clock-tunable filter is, furthermore, coupled to the digital clocking signal so that the frequency of the clock-tunable filter is adjusted in relation to a sampling frequency at which the digital clocking signal operates. The self-tuning filter may be applied to an input of a data acquisition unit and applied to an input having a variable sampling frequency. A method of controlling the frequency of a clock-tunable filter is also disclosed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Raman spectroscopy is a noninvasive, nondestructive tool for capturing multiplexed biochemical information across diverse molecular species including proteins, lipids, DNA, and mineralizations. Based on light scattering from molecules, cells, and tissues, it is possible to detect molecular fingerprints and discriminate between subtly different members of each biochemical class. Raman spectroscopy is ideal for detecting perturbations from the expected molecular structure such as those occurring during senescence and the modification of long-lived proteins by metabolic intermediates as we age. Here, we describe the sample preparation, data acquisition, signal processing, data analysis and interpretation involved in using Raman spectroscopy for detecting age-related protein modifications in complex biological tissues.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The injection stretch blow moulding process is used to manufacture PET containers used in the soft drinks and carbonated soft drinks industry. The process consists of a test tube like specimen known as a preform which is heated, stretch and blown into a mould to form the container. This research is focused on developing a validated simulation of the process thus enabling manufacturers to design their products in a virtual environment without the need to waste time, material and energy. The simulation has been developed using the commercial FEA package Abaqus and has been validated using state of the art data acquisition system consisting of measurements for preform temperature (inner and outer wall) using a device known as THERMOscan (Figure 1), stretch rod force and velocity, internal pressure and air temperature inside the preform using an instrumented stretch rod and the?exact?timing of when the preform touches the mould wall using contact sensors.? In addition, validation studies have also been performed by blowing a perform without a mould and using high sped imaging technology in cooperation with an advanced digital image correlation system (VIC 3D) to provided new quantitative information on the behaviour of PET during blowing.? The approach has resulted in a realistic simulation in terms of accurate input parameters, preform shape evolution and prediction of final properties.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Capillary-based systems for measuring the input impedance of musical wind instruments were first developed in the mid-20th century and remain in widespread use today. In this paper, the basic principles and assumptions underpinning the design of such systems are examined. Inexpensive modifications to a capillary-based impedance measurement set-up made possible due to advances in computing and data acquisition technology are discussed. The modified set-up is able to measure both impedance magnitude and impedance phase even though it only contains one microphone. In addition, a method of calibration is described that results in a significant improvement in accuracy when measuring high impedance objects on the modified capillary-based system. The method involves carrying out calibration measurements on two different objects whose impedances are well-known theoretically. The benefits of performing two calibration measurements (as opposed to the one calibration measurement that has been traditionally used) are demonstrated experimentally through input impedance measurements on two test objects and a Boosey and Hawkes oboe. © S. Hirzel Verlag · EAA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tissue microarrays (TMAs) represent a powerful method for undertaking large-scale tissue-based biomarker studies. While TMAs offer several advantages, there are a number of issues specific to their use which need to be considered when employing this method. Given the investment in TMA-based research, guidance on design and execution of experiments will be of benefit and should help researchers new to TMA-based studies to avoid known pitfalls. Furthermore, a consensus on quality standards for TMA-based experiments should improve the robustness and reproducibility of studies, thereby increasing the likelihood of identifying clinically useful biomarkers. In order to address these issues, the National Cancer Research Institute Biomarker and Imaging Clinical Studies Group organized a 1-day TMA workshop held in Nottingham in May 2012. The document herein summarizes the conclusions from the workshop. It includes guidance and considerations on all aspects of TMA-based research, including the pre-analytical stages of experimental design, the analytical stages of data acquisition, and the postanalytical stages of data analysis. A checklist is presented which can be used both for planning a TMA experiment and interpreting the results of such an experiment. For studies of cancer biomarkers, this checklist could be used as a supplement to the REMARK guidelines.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The commonly used British Standard constant head triaxial permeability test for testing of fine-grained soils is relatively time consuming. A reduction in the required time for soil permeability testing would provide potential cost savings to the construction industry, particularly in the construction quality assurance of landfill clay liners. The purpose of this paper is to evaluate an alternative approach of measuring permeability of fine-grained soils benefiting from accelerated time scaling for seepage flow when testing specimens in elevated gravity conditions provided by a centrifuge. As part of the investigation, an apparatus was designed and produced to measure water flow through soil samples under conditions of elevated gravitational acceleration using a small desktop laboratory centrifuge. A membrane was used to hydrostatically confine the test sample. A miniature data acquisition system was designed and incorporated in the apparatus to monitor and record changes in head and flow throughout the tests. Under enhanced gravity in the centrifuge, the flow through the sample was under ‘variable head' conditions as opposed to ‘constant head' conditions as in the classic constant head permeability tests conducted at 1 g . A mathematical model was developed for analysis of Darcy's coefficient of permeability under conditions of elevated gravitational acceleration and verified using the results obtained. The test data compare well with the results on analogous samples obtained using the classical British Standard constant head permeability tests.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The increased complexity and interconnectivity of Supervisory Control and Data Acquisition (SCADA) systems in the Smart Grid has exposed them to a wide range of cyber-security issues, and there are a multitude of potential access points for cyber attackers. This paper presents a SCADA-specific cyber-security test-bed which contains SCADA software and communication infrastructure. This test-bed is used to investigate an Address Resolution Protocol (ARP) spoofing based man-in-the-middle attack. Finally, the paper proposes a future work plan which focuses on applying intrusion detection and prevention technology to address cyber-security issues in SCADA systems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Increased complexity and interconnectivity of Supervisory Control and Data Acquisition (SCADA) systems in Smart Grids potentially means greater susceptibility to malicious attackers. SCADA systems with legacy communication infrastructure have inherent cyber-security vulnerabilities as these systems were originally designed with little consideration of cyber threats. In order to improve cyber-security of SCADA networks, this paper presents a rule-based Intrusion Detection System (IDS) using a Deep Packet Inspection (DPI) method, which includes signature-based and model-based approaches tailored for SCADA systems. The proposed signature-based rules can accurately detect several known suspicious or malicious attacks. In addition, model-based detection is proposed as a complementary method to detect unknown attacks. Finally, proposed intrusion detection approaches for SCADA networks are implemented and verified using a ruled based method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Increased complexity and interconnectivity of Supervisory Control and Data Acquisition (SCADA) systems in Smart Grids potentially means greater susceptibility to malicious attackers. SCADA systems with legacy communication infrastructure have inherent cyber-security vulnerabilities as these systems were originally designed with little consideration of cyber threats. In order to improve cyber-security of SCADA networks, this paper presents a rule-based Intrusion Detection System (IDS) using a Deep Packet Inspection (DPI) method, which includes signature-based and model-based approaches tailored for SCADA systems. The proposed signature-based rules can accurately detect several known suspicious or malicious attacks. In addition, model-based detection is proposed as a complementary method to detect unknown attacks. Finally, proposed intrusion detection approaches for SCADA networks are implemented and verified via Snort rules.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper studies the impact of tower shadow effect on the power output of a fixed-speed wind farm. A data acquisition unit was placed at a wind farm in Northern Ireland which consists of ten fixed-speed wind turbines. The recording equipment logged the wind farmpsilas electrical data, which was time stamped using the global positioning network. Video footage of the wind farm was recorded and from it the blade angle of each turbine was determined with respect to time. Using the blade angle data and the wind farmpsilas power output, studies where performed to ascertain the extent of tower shadow effect on power fluctuation. This paper presents evidence that suggests that tower shadow effect has a significant impact on power fluctuation and that this effect is increased due to the synchronising of turbine blades around the tower region.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The impact of power fluctuations arising from fixed-speed wind turbines on the magnitude and frequency of inter-area oscillations has been investigated. The authors introduced data acquisition equipment to record the power flow on the interconnector between the Northern Ireland and Republic of Ireland systems. Through monitoring the interconnector oscillation using a fast Fourier transform, it was possible to determine the magnitude and frequency of the inter-area oscillation between the two systems. The impact of tower shadow on the output power from a wind farm was analysed using data recorded on site. A case study investigates the effect on the system of the removal of a large fixed-speed wind farm. Conclusions are drawn on the impact that conventional generation and the output from fixed-speed wind farms have on the stability of the Irish power system.