275 resultados para X-ray technique
Resumo:
X-ray backscatter imaging can be used for a wide range of imaging applications, in particular for industrial inspection and portal security. Currently, the application of this imaging technique to the detection of landmines is limited due to the surrounding sand or soil strongly attenuating the 10s to 100s of keV X-rays required for backscatter imaging. Here, we introduce a new approach involving a 140 MeV short-pulse (< 100 fs) electron beam generated by laser wakefield acceleration to probe the sample, which produces Bremsstrahlung X-rays within the sample enabling greater depths to be imaged. A variety of detector and scintillator configurations are examined, with the best time response seen from an absorptive coated BaF2 scintillator with a bandpass filter to remove the slow scintillation emission components. An X-ray backscatter image of an array of different density and atomic number items is demonstrated. The use of a compact laser wakefield accelerator to generate the electron source, combined with the rapid development of more compact, efficient and higher repetition rate high power laser systems will make this system feasible for applications in the field.
Resumo:
X-ray spectra of the late-type star AB Dor obtained with the XMM-Newton satellite are analyzed. AB Dor was particularly active during the observations. An emission measure reconstruction technique is employed to analyze flare and quiescent spectra, with emphasis on the Fe XVII 15 - 17 angstrom wavelength region. The Fe XVII 16.78 angstrom/ 15.01 angstrom line ratio increases significantly in the hotter flare plasma. This change in the ratio is opposite to the theoretical predictions and is attributed to the scattering of 15.01 angstrom line photons from the line of sight. The escape probability technique indicates an optical depth of approximate to 0.4 for the 15.01 angstrom line. During the flare, the electron density is 4.4(-1.6)(+2.7) x 10(10) cm(-3), and the fractional Fe abundance is 0.5 +/- 0.1 of the solar photospheric value Using these parameters, a path length of approximate to 8000 km is derived. There is no evidence of opacity in the quiescent X-ray spectrum of the star.
Resumo:
Charge exchange followed by radiative stabilization are the main processes responsible for the recent observations of X-ray emission from comets in their approach to the Sun. A new apparatus was constructed at JPL to measure, in collisions of HCIs with atoms and molecules, (a) absolute cross sections for single and multiple charge exchange, and (b) normalized X-ray emission cross sections. The ions are produced by the JPL HCI Facility and passed through a neutral-gas target cell. The product charge states are analyzed by a retarding potential difference technique. Results are made absolute by measuring target pressure, and incident and product ion currents. X-rays emitted from the product ions are detected with a Ge solid-state detector having a resolution of approximately 100 eV. X-ray astronomy has taken major steps forward with the recent launch of the high-resolution satellites Chandra and Newton. The cross sections reported herein are essential for the development of the solar wind comet interaction models inspired by these observations.
Resumo:
Context. The I(15.01 Å)/I(16.78 Å) emission line intensity ratio in Fe xvii has been reported to deviate from its theoretical value
in solar and stellar X-ray spectra. This is attributed to opacity in the 15.01 Å line, leading to a reduction in its intensity, and was
interpreted in terms of a geometry in which the emitters and absorbers are spatially distinct.
Aims. We study the I(15.01 Å)/I(16.78 Å) intensity ratio for the active cool dwarf EV Lac, in both flare and quiescent spectra.
Methods. The observations were obtained with the Reflection Grating Spectrometer on the XMM-Newton satellite. The emission
measure distribution versus temperature reconstruction technique is used for our analysis.
Results. We find that the 15.01 Å line exhibits a significant enhancement in intensity over the optically thin value. To our knowledge,
this is the first time that such an enhancement has been detected on such a sound statistical basis. We interpret this enhancement
in terms of a geometry in which the emitters and absorbers are not spatially distinct, and where the geometry is such that resonant
pumping of the upper level has a greater effect on the observed line intensity than resonant absorption in the line-of-sight.
Resumo:
Through the use of time-integrated space-resolved keV spectroscopy, we investigate line plasmas showing gain in Ne-like nickel, copper, and zinc for irradiation using the prepulse technique. The experiments were conducted at 1.06 mu m with the prepulse to main pulse intensity contrast ranging from 10(-6) to 10(-2). The effect of the prepulses on the plasma conditions is inferred through spectroscopic line ratio diagnostics for the electron temperature, the Ne-like ground-state density, and the lateral size of the Ne-like region. It is observed that neither the value of the electronic temperature nor its spatially resolved profile along the linear focus axis varies significantly with the prepulse level, contrary to the lateral width and the density of the Ne-like region in the plasma, which are seen to increase. These results explain, at least in part, why prepulsed x-ray lasers show such high gain and brightness.
Resumo:
Through the use of time-integrated space-resolved keV spectroscopy, we characterize line plasmas showing gain in Ne-like Zn with prepulsed irradiation to explain the enhanced performances of x-ray lasers using the prepulse technique. It is observed that the value of the electron temperature does not vary significantly with prepulse level, nor does its spatially resolved profile along the line. The lateral width and density of the Ne-like region in the plasma are seen to increase with the prepulse level. (C) 1995 Optical Society of America
Resumo:
For the first time, the technique of point projection absorption spectroscopy - which uses an intense, point source of X-rays to project and spectrally disperse an image of a plasma onto a detector- has been shown to be applicable to the study of expanding aluminium plasmas generated by approximately 80ps (2-omega) laser pulses. Massive, stripe targets of approximately 125-mu-m width and wire targets of 25-mu-m diameter have been studied. Using a PET Bragg crystal as the dispersive element, a resolving power of approximately 3500 was achieved with spatial resolution at the 5-mu-m level in frame times of the order of 80ps. Reduction of the data for times up to 150ps after the peak of the incident laser pulse produced estimates of the temperature and densities present, as a function of space and time.
Resumo:
A detailed knowledge of the physical phenomena underlying the generation and the transport of fast electrons generated in high-intensity laser-matter interactions is of fundamental importance for the fast ignition scheme for inertial confinement fusion.
Here we report on an experiment carried out with the VULCAN Petawatt beam and aimed at investigating the role of collisional return currents in the dynamics of the fast electron beam. To that scope, in the experiment counter-propagating electron beams were generated by double-sided irradiation of layered target foils containing a Ti layer. The experimental results were obtained for different time delays between the two laser beams as well as for single-sided irradiation of the target foils. The main diagnostics consisted of two bent mica crystal spectrometers placed at either side of the target foil. High-resolution X-ray spectra of the Ti emission lines in the range from the Ly alpha to the K alpha line were recorded. In addition, 2D X-ray images with spectral resolution were obtained by means of a novel diagnostic technique, the energy-encoded pin-hole camera, based on the use of a pin-hole array equipped with a CCD detector working in single-photon regime. The spectroscopic measurements suggest a higher target temperature for well-aligned laser beams and a precise timing between the two beams. The experimental results are presented and compared to simulation results.
Resumo:
The subambient behavior of aqueous mannitol solutions is of considerable relevance to the preparation of freeze dried formulations. In this investigation the properties of 3% w/v mannitol solutions were investigated using differential scanning calorimetry (DSC), cold stage microscopy (CSM), and X-ray diffraction (XRD) to identify the thermal transitions and structural transformations undergone by this system. It was found that on cooling from ambient the system formed ice at circa -20°C while a further exotherm was seen at approximately -30°C. Upon reheating an endotherm was seen at circa -30°C followed immediately by an exotherm at circa -25°C. Temperature cycling indicated that the thermal transitions observed upon reheating were not reversible. Modulated temperature DSC (MTDSC) indicated that the transitions observed upon reheating corresponded to a glass transition immediately followed by recrystallization, XRD data showed that recrystallization was into the ß form. Annealing at -35°C for 40 min prior to cooling and reheating resulted in a maximum enthalpy being observed for the reheating exotherm. It is concluded that on cooling 3% w/v aqueous mannitol solutions an amorphous phase is formed that subsequently recrystallises into the ß form. The study has also shown that DSC, CSM, and XRD are useful complementary techniques for the study of frozen systems
Resumo:
High-resolution synchrotron X-ray diffraction was used to study the phase transformations in titanium alloys. Three titanium alloys were investigated: Ti-6Al-4V, Ti-6Al-2Sn-4Zr-2Mo-0.08Si and beta21s. Both room and high temperature measurements were performed. The room temperature experiments were performed to study the structure of the alloys after different heat treatments, namely as received (AR), furnace cooling (FC), water quenching (WQ) and water quenching followed by ageing. The alpha, alpha', alpha'' and beta phases were observed in different combinations depending on the heat treatment conditions and the alloy studied. A multicomponent hexagonal close packed (hcp) alpha phase, with different c and the same a lattice parameters, was detected in Ti-6Al-4V after FC. High temperature synchrotron X-ray diffraction was used for 'in situ' study of the transformations on the sample surface at elevated temperatures. The results were used to trace the kinetics of surface oxidation and the concurrent phase transformations taking place under different conditions. The influence of the temperature and oxygen content on the lattice parameters of the alpha phase was derived and new data obtained on the coefficients of thermal expansion in the different directions of the hcp alpha phase, for Ti-6Al-4V and Ti-6Al-2Sn-4Zr-2Mo-0.08Si.
Resumo:
The effect of differing the datasets used in the modelling of the Ni-like Gd x-ray laser (XRL) is examined through the 1.50 hydro-atomic code, EHYBRID. Two atomic datasets, including energy levels and radiative and collisional excitation rates, are used as input data for the code. It is found that the behaviour of the XRL is somewhat different than might be expected from superficial examination of the atomic data. The similarities in the gain profiles at low densities are found to have encouraging implications. in our attempts to model XRLs.