4 resultados para Test (assessment)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The photocatalytic activity of self-cleaning glass is assessed using a resazurin (Rz) photocatalyst activity indicator ink, i.e. Rz paii, via both the rate of change in the colour of the ink (blue to pink), R(Abs), and the rate of change in the fluorescence intensity, R(Fl), (λ(excitation) = 593 nm; λ(emission) = 639 nm) of the ink. In both cases the kinetics are zero order. Additional work with a range of glass samples of different photocatalytic activity reveal R(Abs) is directly related to R(Fl), thereby showing that the latter, like the former, can be used to provide a measure of the photocatalytic activity of the sample under test. The measured value of R(Fl) is found to be the same for 5 pieces of, otherwise identical, selfcleaning glass with: black, red, blue, yellow and no coloured tape stuck to their backs, which demonstrates that R(Fl) measurements can be used to measure photocatalytic activity under conditions of high colour and opacity under which R(Abs) cannot be measured. The relevance of this novel, fluorescence-based paii to the assessment of the activity of highly coloured, opaque photocatalytic samples, such as paints and tiles, is discussed briefly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The availability of BRAF inhibitors has given metastatic melanoma patients an effective new treatment choice and molecular testing to determine the presence or absence of a BRAF codon 600 mutation is pivotal in the clinical management of these patients. This molecular test must be performed accurately and appropriately to ensure that the patient receives the most suitable treatment in a timely manner. Laboratories have introduced such testing; however, some experience low sample throughput making it critical that an external quality assurance programme is available to help promote a high standard of testing, reporting and provide an educational aspect for BRAF molecular testing. Laboratories took part in three rounds of external quality assessment (EQA) during a 12-month period giving participants a measure of the accuracy of genotyping, clinical interpretation of the result and experience in testing a range of different samples. Formalin fixed paraffin embedded tissue sections from malignant melanoma patients were distributed to participants for BRAF molecular testing. The standard of testing was generally high but distribution of a mutation other than the most common, p.(Val600Glu), highlighted concerns with detection or reporting of the presence of rarer mutations. The main issues raised in the interpretation of the results were the importance of clear unambiguous interpretation of the result tailored to the patient and the understanding that the treatment is different from that given to other stratified medicine programmes. The variability in reporting and wide range of methodologies used indicate a continuing need for EQA in this field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Sepsis can lead to multiple organ failure and death. Timely and appropriate treatment can reduce in-hospital mortality and morbidity. Objectives: To determine the clinical effectiveness and cost-effectiveness of three tests [LightCycler SeptiFast Test MGRADE® (Roche Diagnostics, Risch-Rotkreuz, Switzerland); SepsiTest™ (Molzym Molecular Diagnostics, Bremen, Germany); and the IRIDICA BAC BSI assay (Abbott Diagnostics, Lake Forest, IL, USA)] for the rapid identification of bloodstream bacteria and fungi in patients with suspected sepsis compared with standard practice (blood culture with or without matrix-absorbed laser desorption/ionisation time-offlight mass spectrometry). Data sources: Thirteen electronic databases (including MEDLINE, EMBASE and The Cochrane Library) were searched from January 2006 to May 2015 and supplemented by hand-searching relevant articles. Review methods: A systematic review and meta-analysis of effectiveness studies were conducted. A review of published economic analyses was undertaken and a de novo health economic model was constructed. A decision tree was used to estimate the costs and quality-adjusted life-years (QALYs) associated with each test; all other parameters were estimated from published sources. The model was populated with evidence from the systematic review or individual studies, if this was considered more appropriate (base case 1). In a secondary analysis, estimates (based on experience and opinion) from seven clinicians regarding the benefits of earlier test results were sought (base case 2). A NHS and Personal Social Services perspective was taken, and costs and benefits were discounted at 3.5% per annum. Scenario analyses were used to assess uncertainty. Results: For the review of diagnostic test accuracy, 62 studies of varying methodological quality were included. A meta-analysis of 54 studies comparing SeptiFast with blood culture found that SeptiFast had an estimated summary specificity of 0.86 [95% credible interval (CrI) 0.84 to 0.89] and sensitivity of 0.65 (95% CrI 0.60 to 0.71). Four studies comparing SepsiTest with blood culture found that SepsiTest had an estimated summary specificity of 0.86 (95% CrI 0.78 to 0.92) and sensitivity of 0.48 (95% CrI 0.21 to 0.74), and four studies comparing IRIDICA with blood culture found that IRIDICA had an estimated summary specificity of 0.84 (95% CrI 0.71 to 0.92) and sensitivity of 0.81 (95% CrI 0.69 to 0.90). Owing to the deficiencies in study quality for all interventions, diagnostic accuracy data should be treated with caution. No randomised clinical trial evidence was identified that indicated that any of the tests significantly improved key patient outcomes, such as mortality or duration in an intensive care unit or hospital. Base case 1 estimated that none of the three tests provided a benefit to patients compared with standard practice and thus all tests were dominated. In contrast, in base case 2 it was estimated that all cost per QALY-gained values were below £20,000; the IRIDICA BAC BSI assay had the highest estimated incremental net benefit, but results from base case 2 should be treated with caution as these are not evidence based. Limitations: Robust data to accurately assess the clinical effectiveness and cost-effectiveness of the interventions are currently unavailable. Conclusions: The clinical effectiveness and cost-effectiveness of the interventions cannot be reliably determined with the current evidence base. Appropriate studies, which allow information from the tests to be implemented in clinical practice, are required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Steady-state computational fluid dynamics (CFD) simulations are an essential tool in the design process of centrifugal compressors. Whilst global parameters, such as pressure ratio and efficiency, can be predicted with reasonable accuracy, the accurate prediction of detailed compressor flow fields is a much more significant challenge. Much of the inaccuracy is associated with the incorrect selection of turbulence model. The need for a quick turnaround in simulations during the design optimisation process, also demands that the turbulence model selected be robust and numerically stable with short simulation times.
In order to assess the accuracy of a number of turbulence model predictions, the current study used an exemplar open CFD test case, the centrifugal compressor ‘Radiver’, to compare the results of three eddy viscosity models and two Reynolds stress type models. The turbulence models investigated in this study were (i) Spalart-Allmaras (SA) model, (ii) the Shear Stress Transport (SST) model, (iii) a modification to the SST model denoted the SST-curvature correction (SST-CC), (iv) Reynolds stress model of Speziale, Sarkar and Gatski (RSM-SSG), and (v) the turbulence frequency formulated Reynolds stress model (RSM-ω). Each was found to be in good agreement with the experiments (below 2% discrepancy), with respect to total-to-total parameters at three different operating conditions. However, for the off-design conditions, local flow field differences were observed between the models, with the SA model showing particularly poor prediction of local flow structures. The SST-CC showed better prediction of curved rotating flows in the impeller. The RSM-ω was better for the wake and separated flow in the diffuser. The SST model showed reasonably stable, robust and time efficient capability to predict global and local flow features.