71 resultados para SOLID-LIQUID EXTRACTION


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes the development of the first ion pair solid phase extraction technique (IPSPE), which has been applied to the extraction of metformin from plasma samples. In addition an ion pair chromatographic method was developed for the specific HPLC determination of metformin. Several extraction and HPLC methods have been described previously for metformin, however, most of them did not solve the problems associated with the high polarity of this drug. Drug recovery in the developed method was found to be more than 98%. The limit of detection and limit of quantification was 3 and 5 ng/ml, respectively. The intraday and interday precision (measured by coefficient of variation, CV%) was always less than 9%. The accuracy (measured by relative error, R.E.%) was always less than 6.9%. Stability analysis showed that metformin is stable for at least 3 months when stored at -70degreesC. The method has been applied to 150 patient samples as part of a medication adherence study. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid liquid chromatographic-tandem mass spectrometric (LC-MS/MS) multi-residue method for the simultaneous quantitation and identification of sixteen synthetic growth promoters and bisphenol A in bovine milk has been developed and validated. Sample preparation was straightforward, efficient and economically advantageous. Milk was extracted with acetonitrile followed by phase separation with NaCl. After centrifugation, the extract was purified by dispersive solid-phase extraction with C18 sorbent material. The compounds were analysed by reversed-phase LC-MS/MS using both positive and negative ionization and operated in multiple reaction monitoring (MRM) mode, acquiring two diagnostic product ions from each of the chosen precursor ions for unambiguous confirmation. Total chromatographic run time was less than 10 min for each sample. The method was validated at a level of 1 mu g L-1. A wide variety of deuterated internal standards were used to improve method performance. The accuracy and precision of the method were satisfactory for all analytes. The confirmative quantitative liquid chromatographic tandem mass spectrometric (LC-MS/MS) method was validated according to Commission Decision 2002/657/EC. The decision limit (CC alpha) and the detection capability (CC beta) were found to be below the chosen validation level of 1 mu g L-1 for all compounds. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ionic liquid 1-ethyl-3-methylimidazolium bis{(trifluoromethyl)sulfonyl}amide ([C(2)mim][NTf2]) was tested as solvent for the separation of aromatic and aliphatic hydrocarbons containing 7 or 8 carbon atoms (the C-7- and C-8-fractions). The liquid-liquid equilibria (LLE) of the ternary systems (heptane + toluene + [C(2)mim][NTf2]) and (octane + ethylbenzene + [C(2)mim][NTf2]), at 25 degrees C, were experimentally determined. The performance of the ionic liquid as the solvent in such systems was evaluated by means of the calculation of the solute distribution ratio and the selectivity. The results were compared to those previously reported for the extraction of benzene from its mixtures with hexane by using the same ionic liquid, therefore analysing the influence of the size of the hydrocarbons. It was found that the ionic liquid is also good for the extraction of C-7- and C-8- fraction aromatic compounds, just a greater amount of ionic liquid being needed to perform an equivalently efficient separation than for the C-6-fraction. It is also discussed how [C(2)mim][NTf2] performs comparably better than the conventional solvent sulfolane. The original 'Non-Random Two-Liquid' (NRTL) equation was used to adequately correlate the experimental LLE data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Solid-phase extraction (SPE) and direct competitive chemiluminescence enzyme immunoassay (dcCL-EIA) were combined for the detection of organophosphorus pesticides (OPs) in environmental water samples. dcCL-EIA based on horseradish peroxidase labeled with a broad-specificity monoclonal antibody against OPs was developed, and the effects of several physicochemical parameters on dcCL-EIA performance were studied. SPE was used for the pretreatment of water samples to remove interfering substances and to concentrate the OP analytes. The coupling of SPE and dcCL-EIA can detect seven OPs (parathion, coumaphos, phoxim, quinalphos, triazophos, dichlofenthion, and azinphos-ethyl) with the limit of quantitation below 0.1 ng/mL. The recoveries of OPs from spiked water samples ranged from 62.5% to 131.7% by SPE-dcCL-EIA and 69.5% to 112.3% by SPE-HPLC-MS/MS. The screening of OP residues in real-world environmental water samples by the developed SPE-dcCL-EIA and their confirmatory analysis using SPE-HPLC-MS/MS demonstrated that the assay is ideally suited as a monitoring method for OP residues prior to chromatographic analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A molecularly imprinted polymer (MIP) was prepared with caffeine as the template molecule. Thermal polymerisation (60°C) was optimised, varying ratios of monomer, cross linker and template. The polymer was used as a solid-phase extraction (SPE) sorbent, for selective trapping and pre-concentration of caffeine. Caffeine was loaded on the MIP-SPE cartridge using different loading conditions (solvents, pH value). Washing and elution of the caffeine bound to the MIP was studied utilising different protocols. The extraction protocol was successfully applied to the direct extraction of caffeine from beverages and spiked human plasma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Molecularly imprinted polymers (MIPs) selective for scopolamine were produced using hyoscyamine (a close structural analogue) as template molecule. The produced polymers were used as media for solid-phase extraction, exhibiting selective binding properties for the analyte from biological samples. Human and calf urine and serum were processed on the MIP under various extraction protocols. The best performance was observed after loading the analyte in aqueous environment facilitating retention on the MIP by non-selective hydrophobic interactions. The MIPs were subsequently washed using an optimised solvent system to enable selective desorption of the analyte. Other related and non-related compounds were accessed to evaluate molecular recognition properties. Recoveries of up to 79% were achieved for the analyte of interest from biological samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the extraction of C5–C8 linear α-olefins from olefin/paraffin mixtures of the same carbon number via a reversible complexation with a silver salt (silver bis(trifluoromethylsulfonyl)imide, Ag[Tf2N]) to form room temperature ionic liquids [Ag(olefin)x][Tf2N]. From the experimental (liquid + liquid) equilibrium data for the olefin/paraffin mixtures and Ag[Tf2N], 1-pentene showed the best separation performance while C7 and C8 olefins could only be separated from the corresponding mixtures on addition of water which also improves the selectivity at lower carbon numbers like the C5 and C6, for example. Using infrared and Raman spectroscopy of the complex and Ag[Tf2N] saturated by olefin, the mechanism of the extraction was found to be based on both chemical complexation and the physical solubility of the olefin in the ionic liquid ([Ag(olefin)x][Tf2N]). These experiments further support the use of such extraction techniques for the separation of olefins from paraffins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have resolved the solid-liquid phase transition of carbon at pressures around 150GPa. High-pressure samples of different temperatures were created by laser-driven shock compression of graphite and varying the initial density from 1.30g/cm3 to 2.25g/cm3. In this way, temperatures from 5700K to 14,500K could be achieved for relatively constant pressure according to hydrodynamic simulations. From measuring the elastic X-ray scattering intensity of vanadium K-alpha radiation at 4.95keVat a scattering angle of 126°, which is very sensitive to the solid-liquid transition, we can determine whether the sample had transitioned to the fluid phase. We find that samples of initial density 1.3g/cm3 and 1.85g/cm3 are liquid in the compressed states, whereas samples close to the ideal graphite crystal density of 2.25g/cm3 remain solid, probably in a diamond-like state.