2 resultados para RESPIRATORY FUNCTION TESTS


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Lumacaftor/ivacaftor combination therapy demonstrated clinical benefits inpatients with cystic fibrosis homozygous for the Phe508del CFTR mutation.Pretreatment lung function is a confounding factor that potentially impacts the efficacyand safety of lumacaftor/ivacaftor therapy. Methods Two multinational, randomised, double-blind, placebo-controlled, parallelgroupPhase 3 studies randomised patients to receive placebo or lumacaftor (600 mgonce daily [qd] or 400 mg every 12 hours [q12h]) in combination with ivacaftor (250 mgq12h) for 24 weeks. Prespecified analyses of pooled efficacy and safety data by lungfunction, as measured by percent predicted forced expiratory volume in 1 second(ppFEV1), were performed for patients with baseline ppFEV1 <40 (n=81) and ≥40(n=1016) and screening ppFEV1 <70 (n=730) and ≥70 (n=342). These studies wereregistered with ClinicalTrials.gov (NCT01807923 and NCT01807949). Findings The studies were conducted from April 2013 through April 2014.Improvements in the primary endpoint, absolute change from baseline at week 24 inppFEV1, were observed with both lumacaftor/ivacaftor doses in the subgroup withbaseline ppFEV1 <40 (least-squares mean difference versus placebo was 3∙7 and 3.3percentage points for lumacaftor 600 mg qd/ivacaftor 250 mg q12h and lumacaftor 400mg q12h/ivacaftor 250 mg q12h, respectively [p<0∙05] and in the subgroup with baselineppFEV1 ≥40 (3∙3 and 2∙8 percentage points, respectively [p<0∙001]). Similar absoluteimprovements versus placebo in ppFEV1 were observed in subgroups with screening 4ppFEV1 <70 (3∙3 and 3∙3 percentage points for lumacaftor 600 mg qd/ivacaftor 250 mgq12h and lumacaftor 400 mg q12h/ivacaftor 250 mg q12h, respectively [p<0∙001]) and≥70 (3∙3 and 1∙9 percentage points, respectively [p=0.002] and [p=0∙079]). Increases inBMI and reduction in number of pulmonary exacerbation events were observed in bothLUM/IVA dose groups vs placebo across all lung function subgroups. Treatment wasgenerally well tolerated, although the incidence of some respiratory adverse events washigher with active treatment than with placebo. Interpretation Lumacaftor/ivacaftor combination therapy benefits patients homozygousfor Phe508del CFTR who have varying degrees of lung function impairment. Funding Vertex Pharmaceuticals Incorporated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work was to track and verify the delivery of respiratory-gated irradiations, performed with three versions of TrueBeam linac, using a novel phantom arrangement that combined the OCTAVIUS® SRS 1000 array with a moving platform. The platform was programmed to generate sinusoidal motion of the array. This motion was tracked using the real-time position management (RPM) system and four amplitude gating options were employed to interrupt MV beam delivery when the platform was not located within set limits. Time-resolved spatial information extracted from analysis of x-ray fluences measured by the array was compared to the programmed motion of the platform and to the trace recorded by the RPM system during the delivery of the x-ray field. Temporal data recorded by the phantom and the RPM system were validated against trajectory log files, recorded by the linac during the irradiation, as well as oscilloscope waveforms recorded from the linac target signal. Gamma analysis was employed to compare time-integrated 2D x-ray dose fluences with theoretical fluences derived from the probability density function for each of the gating settings applied, where gamma criteria of 2%/2 mm, 1%/1 mm and 0.5%/0.5 mm were used to evaluate the limitations of the RPM system. Excellent agreement was observed in the analysis of spatial information extracted from the SRS 1000 array measurements. Comparisons of the average platform position with the expected position indicated absolute deviations of  <0.5 mm for all four gating settings. Differences were observed when comparing time-resolved beam-on data stored in the RPM files and trajectory logs to the true target signal waveforms. Trajectory log files underestimated the cycle time between consecutive beam-on windows by 10.0  ±  0.8 ms. All measured fluences achieved 100% pass-rates using gamma criteria of 2%/2 mm and 50% of the fluences achieved pass-rates  >90% when criteria of 0.5%/0.5 mm were used. Results using this novel phantom arrangement indicate that the RPM system is capable of accurately gating x-ray exposure during the delivery of a fixed-field treatment beam.