42 resultados para On-line monitoring


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

TiO2 photocatalysis is a promising technology for the destruction of organic pollutants in both waste and potable waters with the mineralisation of a wide range of compounds having been reported. TiO 2 has many advantages over other semiconductors, it is highly photoreactive, cheap, non-toxic, chemically and biologically inert, and photostable. The photocatalytic activity of TiO2 has been shown to depend upon many criteria including the ratio of anatase/rutile crystal phase, particle size and oxidation state. This paper reports the use of optical surface second harmonic generation (SSHG) to monitor modifications in TiO 2 powder induced following laser treatment. SSHG is a non-contact, non-destructive technique, which is highly sensitive to both surface chemical and physical changes. Results show that three different SSH intensities were observable as the TiO2 samples were irradiated with the laser light. These regions were related to changes in chemical characteristics and particle size of the TiO2 powder

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is an increasing interest in the biomedical field to create implantable medical devices to provide a temporary mechanical function for use inside the human body. In many of these applications bioresorbable polymer composites using PLLA with β-TCP , are increasingly being used due to their biocompatability, biodegradability and mechanical strength.1,3 These medical devices can be manufactured using conventional plastics processing methods such as injection moulding and extrusion, however there is great need to understand and control the process due to a lack of knowledge on the influence of processing on material properties. With the addition of biocompatible additives there is also a requirement to be able to predict the quality and level of dispersion within the polymer matrix. On-line UV-Vis spectroscopy has been shown to monitor the quality of fillers in polymers. This can eliminate time consuming and costly post-process evaluation of additive dispersion. The aim of this work was to identify process and performance relationships of PLLA/β-TCP composites with respect to melt-extrusion conditions. This is part of a wider study into on-line process monitoring of bioresorbable polymers as used in the medical industry.
These results show that final properties of the PLLA/ β-TCP composite are highly influenced by the particle size and loading. UV-Vis spectroscopy can be used on-line to monitor the final product and this can be utilised as a valuable tool for quality control in an application where consistent performance is of paramount importance.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Calibration is essential for interpretation of radiocarbon dates, especially when the 14C dates are compared to historical or climatic records with a different chronological basis. 14C ages of samples from the marine environment, such as shells or fish bones, or samples with a marine component, such as human bone in coastal regions, require an additional consideration because of the reservoir age of the ocean. While the pre-industrial global mean reservoir correction, R(t), is about 400 years, local variations (?R) can be several hundred years or more. ?R compilations on a global scale have been undertaken previously (Stuiver et al. 1986; Stuiver and Braziunas 1993), but have not been updated recently. Here we describe an on-line reservoir correction database accessed via mapping software. Rather than publishing a static ?R compilation, new data will be incorporated when it becomes available. The on-line marine reservoir correction database can be accessed at the website http://www.calib.org/.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador: