18 resultados para Mustafa <Kara>Mustafa <Kara>
Resumo:
A cartographer constructs a map of an individual creative history, that of the American artist kara lynch, as it emerges in connection to a collective history of African American cultural expression. Positioning history as complex, dynamic systems of interwoven memory networks, the map follows lynch’s traversals through various “zones of cultural haunting”: places where collective memories made invisible through systematic processes of cultural erasure may be recovered and revived. Through these traversals, which are inspired by lynch’s “forever project” Invisible, the map covers such terrains as haunted narratives, mechanisms of abstraction and coding within African American media production, water as an informational technology, the distribution of memory in blood, the dialectics of materiality and immateriality that frame considerations of black subjectivity, and the possibility that place of music might not be the site of sound but instead the social production of memory.
Resumo:
Multicore computational accelerators such as GPUs are now commodity components for highperformance computing at scale. While such accelerators have been studied in some detail as stand-alone computational engines, their integration in large-scale distributed systems raises new challenges and trade-offs. In this paper, we present an exploration of resource management alternatives for building asymmetric accelerator-based distributed systems. We present these alternatives in the context of a capabilities-aware framework for data-intensive computing, which uses an enhanced implementation of the MapReduce programming model for accelerator-based clusters, compared to the state of the art. The framework can transparently utilize heterogeneous accelerators for deriving high performance with low programming effort. Our work is the first to compare heterogeneous types of accelerators, GPUs and a Cell processors, in the same environment and the first to explore the trade-offs between compute-efficient and control-efficient accelerators on data-intensive systems. Our investigation shows that our framework scales well with the number of different compute nodes. Furthermore, it runs simultaneously on two different types of accelerators, successfully adapts to the resource capabilities, and performs 26.9% better on average than a static execution approach.
Resumo:
A 42-year-old man has been under long-term follow-up since he was a child for congenital glaucoma and buphthalmos in both eyes. His left eye best corrected visual acuity (BCVA) was counting fingers, due to end-stage glaucoma. He was on maximal medical therapy with an intraocular pressure (IOP) maintained at mid to low twenties. His right eye, the only seeing eye, had a BCVA of 6/9. This eye had undergone multiple glaucoma laser and surgical procedures, including an initial first Molteno drainage device inserted superonasally that failed in April 2003 due to fibrotic membrane over the tube opening. As a result, he subsequently had a second Molteno drainage device inserted inferotemporally. To further maximize his vision he had an uncomplicated cataract extraction and intraocular lens implant in December 2004, after which he developed postoperative cystoid macular edema and corneal endothelial failure. He underwent a penetrating keratoplasty in the right eye thereafter in March 2007. After approximately a year, the second Molteno device developed drainage tube retraction, which was managed surgically to maintain optimum IOP in the right eye. His right eye vision to date is maintained at 6/12. © 2011 Mustafa and Azuara-Blanco.
Resumo:
PURPOSE: To evaluate the changes in the Visual Field Index (VFI) in eyes with perimetric glaucomatous progression, and to compare these against stable glaucoma patients.
PATIENTS AND METHODS: Consecutive patients with open angle glaucoma with a minimum of 6 reliable visual fields and 2 years of follow-up were identified. Perimetric progression was assessed by 4 masked glaucoma experts from different units, and classified into 3 categories: "definite progression," "suspected progression," or "no progression." This was compared with the Glaucoma Progression Analysis (GPA) II and VFI linear regression analysis, where progression was defined as a negative slope with significance of <5%.
RESULTS: Three hundred ninety-seven visual fields from 51 eyes of 39 patients were assessed. The mean number of visual fields was 7.8 (SD 1.1) per eye, and the mean follow-up duration was 63.7 (SD 13.4) months. The mean VFI linear regression slope showed an overall statistically significant difference (P<0.001, analysis of variance) for each category of progression. Using expert consensus opinion as the reference standard, both VFI analysis and GPA II had high specificity (0.93 and 0.90, respectively), but relatively low sensitivity (0.45 and 0.41, respectively).
CONCLUSIONS: The mean VFI regression slope in our cohort of eyes without perimetric progression showed a statistically significant difference compared with those with suspected and definite progression. VFI analysis and GPA II both had similarly high specificity but low sensitivity when compared with expert consensus opinion.
Resumo:
Purpose: To evaluate the influence of socioeconomic factors on visual acuity before cataract surgery. ?Methods: The medical case notes of 240 consecutive patients listed for cataract surgery from January 1, 2010, at Grampian University Hospital, Aberdeen, were reviewed retrospectively. Patients with ocular comorbidity were excluded. Demographics, postal codes, and visual acuity were recorded. Scottish Index of Multiple Deprivation was used to determine the deprivation rank. Home location was classified as urban or rural. The effect of these parameters on preoperative visual acuity was investigated using chi-square tests or Fisher exact test as appropriate. ?Results: A total of 184 patients (mean 75 years) were included. A total of 127 (69%) patients had visual acuity of 6/12 or better. An association was found between affluence and preoperative visual acuity of 6/12 or better (?2trend = 4.97, p = 0.03), with a significant rising trend across quintile of deprivation. There was no evidence to suggest association between geographical region and preoperative visual acuity (p = 0.63). ?Conclusion: Affluence was associated with good visual acuity (6/12 or better) before cataract surgery. There was no difference in preoperative visual acuity between rural and urban populations.
Resumo:
Cronobacter (formerly known as Enterobacter sakazakii) is a genus comprising seven species regarded as opportunistic pathogens that can be found in a wide variety of environments and foods, including powdered infant formula (PIF). Cronobacter sakazakii, the major species of this genus, has been epidemiologically linked to cases of bacteremia, meningitis in neonates, and necrotizing enterocolitis, and contaminated PIF has been identified as an important source of infection. Robust and reproducible subtyping methods are required to aid in the detection and investigation, of foodborne outbreaks. In this study, a pulsed-field gel electrophoresis (PFGE) protocol was developed and validated for subtyping Cronobacter species. It was derived from an existing modified PulseNet protocol, wherein XbaI and SpeI were the primary and secondary restriction enzymes used, generating an average of 14.7 and 20.3 bands, respectively. The PFGE method developed was both reproducible and discriminatory for subtyping Cronobacter species.
Resumo:
Objective: To investigate the effect of socioeconomic deprivation on cornea graft survival in the United Kingdom.
Design: Retrospective cohort study.
Participants: All the recipients (n = 13?644) undergoing their first penetrating keratoplasty (PK) registered on the United Kingdom Transplant Registry between April 1999 and March 2011 were included.
Methods: Data of patients' demographic details, indications, graft size, corneal vascularization, surgical complication, rejection episodes, and postoperative medication were collected at the time of surgery and 1, 2, and 5 years postoperatively. Patients with endophthalmitis were excluded from the study. Patients' home postcodes were used to determine the socioeconomic status using a well-validated deprivation index in the United Kingdom: A Classification of Residential Neighborhoods (ACORN). Kaplan–Meier survival and Cox proportional hazards regression were used to evaluate the influence of ACORN categories on 5-year graft survival, and the Bonferroni method was used to adjust for multiple comparisons.
Main Outcome Measures: Patients' socioeconomic deprivation status and corneal graft failure.
Results: A total of 13?644 patients received their first PK during the study periods. A total of 1685 patients (13.36%) were lost to follow-up, leaving 11?821 patients (86.64%) for analysis. A total of 138 of the 11?821 patients (1.17%) developed endophthalmitis. The risk of graft failure within 5 years for the patients classified as hard-pressed was 1.3 times that of the least deprived (hazard ratio, 1.3; 95% confidence interval, 1.1–1.5; P = 0.003) after adjusting for confounding factors and indications. There were no statistically significant differences between the causes of graft failure and the level of deprivation (P = 0.14).
Conclusions: Patients classified as hard-pressed had an increased risk of graft failure within 5 years compared with the least deprived patients.
Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article
Resumo:
The exponential growth in user and application data entails new means for providing fault tolerance and protection against data loss. High Performance Com- puting (HPC) storage systems, which are at the forefront of handling the data del- uge, typically employ hardware RAID at the backend. However, such solutions are costly, do not ensure end-to-end data integrity, and can become a bottleneck during data reconstruction. In this paper, we design an innovative solution to achieve a flex- ible, fault-tolerant, and high-performance RAID-6 solution for a parallel file system (PFS). Our system utilizes low-cost, strategically placed GPUs — both on the client and server sides — to accelerate parity computation. In contrast to hardware-based approaches, we provide full control over the size, length and location of a RAID array on a per file basis, end-to-end data integrity checking, and parallelization of RAID array reconstruction. We have deployed our system in conjunction with the widely-used Lustre PFS, and show that our approach is feasible and imposes ac- ceptable overhead.