18 resultados para Multistage Transmission Network
Resumo:
This study presents a new method for determining the transmission network usage by loads and generators, which can then be used for transmission cost/loss allocation in an explainable and justifiable manner. The proposed method is based on solid physical grounds and circuit theory. It relies on dividing the currents through the network into two components; the first one is attributed to power flows from generators to loads, whereas the second one is because of the generators only. Unlike almost all the available methods, the proposed method is assumption free and hence it is more accurate than similar methods even those having some physical basis. The proposed method is validated through a transformer analogy, and theoretical derivations. The method is verified through application to the IEEE 30 bus system and the IEEE 118 test system. The results obtained verified many desirable features of the proposed method. Being more accurate in determining the network usage, in an explainable transparent manner, and in giving accurate cost signals, indicating the best locations to add loads and generation, are among the many desirable features.
Resumo:
This paper investigates the control and operation of doubly-fed induction generator (DFIG) and fixed-speed induction generator (FSIG) based wind farms under unbalanced grid conditions. A DFIG system model suitable for analyzing unbalanced operation is developed, and used to assess the impact of an unbalanced supply on DFIG and FSIG operation. Unbalanced voltage at DFIG and FSIG terminals can cause unequal heating on the stator windings, extra mechanical stresses and output power fluctuations. These problems are particularly serious for the FSIG-based wind farm without a power electronic interface to the grid. To improve the stability of a wind energy system containing both DFIG and FSIG based wind farms during network unbalance, a control strategy of unbalanced voltage compensation by the DFIG systems is proposed. The DFIG system compensation ability and the impact of transmission network impedance are illustrated. The simulation results implemented in Matlab/Simulink show that the proposed DFIG control system improves not only its own performance, but also the stability of the FSIG system with the same grid connection point during network unbalance.
Resumo:
Cognitive radio network is defined as an intelligent wireless communication network that should be able to adaptively reconfigure its communication parameters to meet the demands of the transmission network or the user. In this context one possible way to utilize unused licensed spectrum without interfering with incumbent users is through spectrum sensing. Due to channel uncertainties, single cognitive (opportunistic) user cannot make a decision reliably and hence collaboration among multiple users is often required. Here collaboration among large number of users tends to increase power consumption and introduces large communication overheads. In this paper, the number of collaborating users is optimized in order to maximize the probability of detection for any given power budget in a cognitive radio network, while satisfying constraints on the false alarm probability. We show that for the maximum probability of detection, collaboration of only a subset of available opportunistic users is required. The robustness of our proposed spectrum sensing algorithm is also examined under flat Rayleigh fading and AWGN channel conditions.
Resumo:
Currently wind power is dominated by onshore wind farms. However, as the demand for power grows driven by security of energy supply issues, dwindling fossil fuel supplies and greenhouse gas emissions reduction targets, offshore wind power will develop rapidly because of the decline of viable onshore sites. The United Kingdom has a target of 21% renewable electricity by 2020 and this is expected to come mostly from wind power. Britain is the most active internationally in terms of offshore wind farm development with almost 48GW in some stage of development. In addition the Scottish Government, the Northern Ireland Executive and the Government of Ireland undertook the 'Irish-Scottish Links on Energy Study' (ISLES), which examined the feasibility of creating an offshore interconnected transmission network and subsea electricity grid based on renewable energy sources off the coast of western Scotland and the Irish Sea. The aim of this paper is to provide an appraisal of offshore wind power development with a focus on the United Kingdom. © 2013 IEEE.
Resumo:
In this paper, the performance of the network coded amplify-forward cooperative protocol is studied. The use of network coding can suppress the bandwidth resource consumed by relay transmission, and hence increase the spectral efficiency of cooperative diversity. A distributed strategy of relay selection is applied to the cooperative scheme, which can reduce system overhead and also facilitate the development of the explicit expressions of information metrics, such as outage probability and ergodic capacity. Both analytical and numerical results demonstrate that the proposed protocol can achieve large ergodic capacity and full diversity gain simultaneously.
Resumo:
This paper presents a new method for transmission loss allocation. The method is based on tracing the complex power flow through the network and determining the share of each load on the flow and losses through each line. Transmission losses are taken into consideration during power flow tracing. Unbundling line losses is carried out using an equation, which has a physical basis, and considers the coupling between active and reactive power flows as well as the cross effects of active and reactive power on active and reactive losses. A tracing algorithm which can be considered direct to a good extent, as there is no need for exhaustive search to determine the flow paths as these are determined in a systematic way during the course of tracing. Results of application of the proposed method are also presented.
Resumo:
A three-phase four-wire shunt active power filter for harmonic mitigation and reactive power compensation in power systems supplying nonlinear loads is presented. Three adaptive linear neurons are used to tackle the desired three-phase filter current templates. Another feedforward three-layer neural network is adopted to control the output filter compensating currents online. This is accomplished by producing the appropriate switching patterns of the converter's legs IGBTs. Adequate tracking of the filter current references is obtained by this method. The active filter injects the current required to compensate for the harmonic and reactive components of the line currents, Simulation results of the proposed active filter indicate a remarkable improvement in the source current waveforms. This is reflected in the enhancement of the unified power quality index defined. Also, the filter has exhibited quite a high dynamic response for step variations in the load current, assuring its potential for real-time applications
Resumo:
The impact that the transmission-line load-network has on the performance of the recently introduced series-L/parallel-tuned Class-E amplifier and the classic shunt-C/series-tuned configuration when compared to optimally derived lumped load networks is discussed. In addition an improved load topology which facilitates harmonic suppression of up to 5 order as required for maximum Class-E efficiency as well as load resistance transformation and a design procedure involving the use of Kuroda's identity and Richard's transformation enable a distributed synthesis process which dispenses with the need for iterative tuning as previously required in order to achieve optimum Class-E operation. © 2005 IEEE.
Resumo:
A graphical method is presented for determining the capability of individual system nodes to accommodate wind power generation. The method is based upon constructing a capability chart for each node at which a wind farm is to be connected. The capability chart defines the domain of allowable power injections at the candidate node, subject to constraints imposed by voltage limits, voltage stability and equipment capability limits being satisfied. The chart is first derived for a two-bus model, before being extended to a multi-node power system. The graphical method is employed to derive the chart for a two-node system, as well as its application to a multi-node power system, considering the IEEE 30-bus test system as a case study. Although the proposed method is derived with the intention of determining the wind farm capacity to be connected at a specific node, it can be used for the analysis of a PQ bus loading as well as generation.
Resumo:
In this paper, analysis and synthesis approach for two new variants within the Class-EF power amplifier (PA) family is elaborated. These amplifiers are classified here as Class-E3 F2 and transmission-line (TL) Class-E3 F 2. The proposed circuits offer means to alleviate some of the major issues faced by existing topologies such as substantial power losses due to the parasitic resistance of the large inductor in the Class-EF load network and deviation from ideal Class-EF operation due to the effect of device output inductance at high frequencies. Both lumped-element and transmission-line load networks for the Class-E 3 F PA are described. The load networks of the Class-E3 F and TL Class-E 3 F2amplifier topologies developed in this paper simultaneously satisfy the Class-EF optimum impedance requirements at fundamental frequency, second, and third harmonics as well as simultaneously providing matching to the circuit optimum load resistance for any prescribed system load resistance. Optimum circuit component values are analytically derived and validated by harmonic balance simulations. Trade-offs between circuit figures of merit and component values with some practical limitations being considered are discussed. © 2010 IEEE.
Resumo:
A novel Class-E power amplifier (PA) topology with transmission-line load network is presented in this brief. When compared with the classic Class-E topology, the new circuit can increase the maximum operating frequency up to 50% higher without trading the other Class-E figures of merit. Neither quarterwave line/massive radio-frequency choke for collector/drain biasing nor additional fundamental-frequency output matching circuit are needed in the proposed PA, thus resulting in a compact design. Closed-form formulations are derived and verified by simulations with practical design limitations carefully taken into consideration and good agreement achieved.
Resumo:
In this paper, characterizing transmission losses according to their origin is carried out. Transmission loss is decomposed into three components. The first is due to the current flow from generators to loads. The second is due to the circulating current between generators. The third represents the contribution of network structure and controls to increasing or decreasing transmission losses. Analytical proofs of the proposed loss decomposition are presented along with methods of allocating each component to the parties contributing to it. Illustration on simple dc and ac systems is presented. Results of application of the proposed method compared with other methods are also presented.
Resumo:
Experimental assessments of the modified power-combining Class-E amplifier are described. The technique used to combine the output of individual power amplifiers (PAs) into an unbalanced load without the need for bulky transformers permits the use of small RF chokes useful for the deployment in the EER transmitter. The modified output load network of the PA results in excellent 50 dBc and 46 dBc second and third-harmonic suppressions, dispensing the need for additional lossy filtering block. Operating from a 3.2 V dc supply voltage, the PA exhibits 64% drain efficiency at 24 dBm output power. Over a wide bandwidth of 350 MHz, drain efficiency of better than 60% at output power higher than 22 dBm were achieved. © 2010 IEICE Institute of Electronics Informati.
Resumo:
Analysis and synthesis of the new Class-EF power amplifier (PA) are presented in this paper. The proposed circuit offers means to alleviate some of the major issues faced by existing Class-EF and Class-EF PAs, such as (1) substantial power losses due to parasitic resistance of the large inductor in the Class-EF load network, (2) unpredictable behaviour of practical lumped inductors and capacitors at harmonic frequencies, and (3) deviation from ideal Class-EF operation mode due to detrimental effects of device output inductance at high frequencies. The transmission-line load network of the Class-EF PA topology elaborated in this paper simultaneously satisfies the Class-EF optimum impedance requirements at fundamental frequency, second, and third harmonics as well as simultaneously providing matching to the circuit optimum load resistance for any prescribed system load resistance. Furthermore, an elegant solution using an open and short-circuit stub arrangement is suggested to overcome the problem encountered in the mm-wave IC realizations of the Class-EF PA load network due to lossy quarter-wave line. © 2010 IEICE Institute of Electronics Informati.