338 resultados para HEART INVOLVEMENT


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The transient receptor potential melastatin 8 (TRPM8) channel has been characterized as a cold and menthol receptor expressed in a subpopulation of sensory neurons but was recently identified in other tissues, including the respiratory tract, urinary system, and vasculature. Thus TRPM8 may play multiple functional roles, likely to be in a tissue- and activation state-dependent manner. We examined the TRPM8 channel presence in large arteries from rats and the functional consequences of their activation. We also aimed to examine whether these channels contribute to control of conscious human skin blood flow. TRPM8 mRNA and protein were detected in rat tail, femoral and mesenteric arteries, and thoracic aorta. This was confirmed in single isolated vascular myocytes by immunocytochemistry. Isometric contraction studies on endothelium-denuded relaxed rat vessels found small contractions on application of the TRPM8-specific agonist menthol (300 microM). However, both menthol and another agonist icilin (50 microM) caused relaxation of vessels precontracted with KCl (60 mM) or the alpha-adrenoceptor agonist phenylephrine (2 microM) and a reduction in sympathetic nerve-mediated contraction. These effects were antagonized by bromoenol lactone treatment, suggesting the involvement of Ca(2+)-independent phospholipase A(2) activation in TRPM8-mediated vasodilatation. In thoracic aorta with intact endothelium, menthol-induced inhibition of KCl-induced contraction was enhanced. This was unaltered by preincubation with either N(omega)-nitro-l-arginine methyl ester (l-NAME; 100 nM), a nitric oxide synthase inhibitor, or the ACh receptor antagonist atropine (1 microM). Application of menthol (3% solution, topical application) to skin caused increased blood flow in conscious humans, as measured by laser Doppler fluximetry. Vasodilatation was markedly reduced or abolished by prior application of l-NAME (passive application, 10 mM) or atropine (iontophoretic application, 100 nM, 30 s at 70 microA). We conclude that TRPM8 channels are present in rat artery vascular smooth muscle and on activation cause vasoconstriction or vasodilatation, dependent on previous vasomotor tone. TRPM8 channels may also contribute to human cutaneous vasculature control, likely with the involvement of additional neuronal mechanisms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Service user and carer involvement in social work education is now well established since its inception as a compulsory requirement in the social work curriculum in the United Kingdom in 2003. Since then, there have been many examples of how such involvement has been approached by education providers. Nevertheless, one of the key obstacles and challenges in this field continues to centre on the need to achieve non-tokenistic user involvement which cements the engagement of service users and carers at the heart of social work education. This paper describes one such initiative where service user and carer colleagues in a university in Northern Ireland have been actively involved in the assessment of first year social work students’ preparation for their first period of practice learning. The paper presents the background to this initiative explaining how the project unfolded; the detailed preparations that were involved and the evidence gathered from evaluations undertaken with the students, service users and carers, and academic colleagues who were all involved. We believe that the findings from this project can contribute to the advancement of existing knowledge in the field in exploring and recommending creative methodologies for user involvement in social work education.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background A previous review suggested that the MacNew Quality of Life Questionnaire was the most appropriate disease-specific measure of health-related quality of life among people with ischaemic heart disease. However, there is ambiguity about the allocation of items to the three factors underlying the MacNew and the factor structure has not been confirmed previously among the people in the UK. Methods The MacNew Questionnaire and the SF-36 were administered to 117 newly admitted patients to a tertiary referral centre in Northern Ireland. All patients had been diagnosed with ischaemic heart disease. Results A confirmatory factor analysis was conducted on the factor structure of the MacNew and the model was found to be an inadequate fit of the data. A quantitative and qualitative analysis of the items suggested that a five factor solution was more appropriate and this was validated by confirmatory factor analysis. This new structure also displayed strong evidence of concurrent validity when compared to the SF-36. Conclusion We recommend that researchers should submit scores obtained from items on the MacNew to secondary analyses after being grouped according to the factor structure proposed in this paper, in order to explore further the most appropriate grouping of items.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigated whether the SF-12 could replace the SF-36 in the measurement of health status among ischaemic heart disease patients. The SF-36 and SF-12 were administered to 105 cardiac patients. The SF-36 summary scores were strongly correlated and similar to the SF-12 summary scores. Also, the SF-12 scores were as powerful as the SF-36 summary scores in discriminating between subgroups of patients categorized according to their self-reported health status or angina classification. It is suggested that when there is a need to collect routine information about cardiac patients' general physical and mental health, the SF-12 is preferable to the SF-36 because of its brevity and acceptability to patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives—To inform researchers and clinicians about the most appropriate generic and disease specific measures of health related quality of life for use among people with ischaemic heart disease. Methods—MEDLINE and BIDS were searched for research papers which contained a report of at least one of the three most common generic instruments or at least one of the five disease specific instruments used with ischaemic heart disease patients. Evidence for the validity, reliability, and sensitivity of these instruments was critically appraised. Results—Of the three generic measures—the Nottingham health profile, sickness impact profile, and short form 36 (SF-36)—the SF-36 appears to offer the most reliable, valid, and sensitive assessment of quality of life. However, a few of the SF-36 subscales lack a sufficient degree of sensitivity to detect change in a patient’s clinical condition. According to the best available evidence, the quality of life after myocardial infarction questionnaire should be preferred to the Seattle angina questionnaire, the quality of life index cardiac version, the angina pectoris quality of life questionnaire, and the summary index. Overall, research on disease specific measures is sparse compared to the number of studies which have investigated generic measures. Conclusions—An assessment of the quality of life of people with ischaemic heart disease should comprise a disease specific measure in addition to a generic measure. The SF-36 and the quality of life after myocardial infarction questionnaire (version 2) are the most appropriate currently available generic and disease specific measures of health related quality of life, respectively. Further research into the measurement of health related quality of life of people with ischaemic heart disease is required in order to address the problems (such as lack of sensitivity to detect change) identified by the review.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increasing emphasis is being placed on the evaluation of health-related quality of life. However, there is no consensus on the definition of this concept and as a result there are a plethora of existing measurement instruments. Head-to-head comparisons of the psychometric properties of existing instruments are necessary to facilitate evidence-based decisions about which instrument should be chosen for routine use. Therefore, an individualised instrument (the modified Patient Generated Index), a generic instrument (the Short Form 36) and a disease-specific instrument (the Quality of Life after Myocardial Infarction questionnaire) were administered to patients with ischaemic heart disease (n=117) and the evidence for the validity, reliability and sensitivity of each instrument was examined and compared. The modified Patient Generated Index compared favourably with the other instruments but none of the instruments examined provided sound evidence for sensitivity to change. Therefore, any recommendation for the use of the individualised approach in the routine collection of health-related quality of life data in clinical practice must be conditional upon the submission of further evidence to support the sensitivity of such instruments.