4 resultados para research planning
em QSpace: Queen's University - Canada
Resumo:
This research explores the policy implications of the approval of three wind energy projects on the Oak Ridges Moraine, and their impact on the Coordinated Land Use Planning Review process. Specifically, it focuses on the involvement of First Nations and environmental non-governmental organizations (ENGOs). This research was conducted through analyzing submissions to the Coordinated Land Use Planning Review, related legislation and policy, Environmental Review Tribunal hearing documents, and interviews with key informants. This research culminates in a number of recommendations to the Coordinated Review informed by the analysis.
Resumo:
A scenario-based two-stage stochastic programming model for gas production network planning under uncertainty is usually a large-scale nonconvex mixed-integer nonlinear programme (MINLP), which can be efficiently solved to global optimality with nonconvex generalized Benders decomposition (NGBD). This paper is concerned with the parallelization of NGBD to exploit multiple available computing resources. Three parallelization strategies are proposed, namely, naive scenario parallelization, adaptive scenario parallelization, and adaptive scenario and bounding parallelization. Case study of two industrial natural gas production network planning problems shows that, while the NGBD without parallelization is already faster than a state-of-the-art global optimization solver by an order of magnitude, the parallelization can improve the efficiency by several times on computers with multicore processors. The adaptive scenario and bounding parallelization achieves the best overall performance among the three proposed parallelization strategies.
Resumo:
In radiotherapy planning, computed tomography (CT) images are used to quantify the electron density of tissues and provide spatial anatomical information. Treatment planning systems use these data to calculate the expected spatial distribution of absorbed dose in a patient. CT imaging is complicated by the presence of metal implants which cause increased image noise, produce artifacts throughout the image and can exceed the available range of CT number values within the implant, perturbing electron density estimates in the image. Furthermore, current dose calculation algorithms do not accurately model radiation transport at metal-tissue interfaces. Combined, these issues adversely affect the accuracy of dose calculations in the vicinity of metal implants. As the number of patients with orthopedic and dental implants grows, so does the need to deliver safe and effective radiotherapy treatments in the presence of implants. The Medical Physics group at the Cancer Centre of Southeastern Ontario and Queen's University has developed a Cobalt-60 CT system that is relatively insensitive to metal artifacts due to the high energy, nearly monoenergetic Cobalt-60 photon beam. Kilovoltage CT (kVCT) images, including images corrected using a commercial metal artifact reduction tool, were compared to Cobalt-60 CT images throughout the treatment planning process, from initial imaging through to dose calculation. An effective metal artifact reduction algorithm was also implemented for the Cobalt-60 CT system. Electron density maps derived from the same kVCT and Cobalt-60 CT images indicated the impact of image artifacts on estimates of photon attenuation for treatment planning applications. Measurements showed that truncation of CT number data in kVCT images produced significant mischaracterization of the electron density of metals. Dose measurements downstream of metal inserts in a water phantom were compared to dose data calculated using CT images from kVCT and Cobalt-60 systems with and without artifact correction. The superior accuracy of electron density data derived from Cobalt-60 images compared to kVCT images produced calculated dose with far better agreement with measured results. These results indicated that dose calculation errors from metal image artifacts are primarily due to misrepresentation of electron density within metals rather than artifacts surrounding the implants.
Resumo:
To reach for a target, we must formulate a movement plan - a difference vector of the target position with respect to the starting hand position. While it is known that the medial part of the intraparietal sulcus (mIPS) and the dorsal premotor (PMd) activity reflects aspects of a kinematic plan for a reaching movement, it is unclear whether or how the two regions may differ. We investigated the functional roles of the mIPS and PMd in the planning of reaching movements using high definition transcranial direct current stimulation (HD-tDCS) and examined changes in horizontal endpoint error when participants were subjected to anodal and cathodal stimulation. The left mIPS and PMd were functionally localized with fMRI in each participant using an interleaved center-out pointing and saccade task and mapped onto the scalp using Brainsight. We adopted a randomized, single-blind design and applied anodal and cathodal stimulation (2mA for 20 min; 3cm radius 4x1 electrode placement) during 4 separate visits scheduled at least a week apart. Each participant performed 250 baseline, stimulation, and post-stimulation memory-guided reaches starting from one of two initial hand positions (IHPs) to one of 4 briefly flashed targets (20 cm distant, 5 cm apart horizontally) while fixating on a straight-ahead cross located at the target line. Separate 2-way repeated measures ANOVAs of horizontal endpoint error difference after cathodal tDCS at each stimulation site revealed a significant IHP by target position interaction effect at the left mIPS, and significant IHP and target main effects at the left PMd. Behaviorally, these effects corresponded to IHP-dependent contractions after cathodal mIPS tDCS and IHP-independent contractions after cathodal PMd tDCS. These results suggest that the movement vector is not yet formed at the input level of mIPS, but is encoded at the input of PMd. These results also indicate that tDCS is a viable, useful method in investigating movement planning properties through temporary perturbations of the system.