2 resultados para combined anaerobic-aerobic-anaoxic treatment

em QSpace: Queen's University - Canada


Relevância:

100.00% 100.00%

Publicador:

Resumo:

GM2 gangliosidoses is a family of severe, neurodegenerative disorders resulting from a deficiency in the β-hexosaminidase A (Hex A) enzyme. This disorder is typically caused by a mutation to either the HEXA gene, causing Tay Sachs disease, or a mutation to the HEXB gene, causing Sandhoff disease. The HEXA and HEXB genes are required to produce the α and β subunits of the Hex A enzyme respectively. Using a Sandhoff disease (SD) mouse model (Hexb-/-) we tested the potential of a low dose of systemically delivered single stranded adeno-associated virus 9 (ssAAV9) expressing human HEXB and human HEXA cDNA under the control of a single promoter through the use of a bicistronic vector design with a P2A linker to correct the neurological phenotype. Neonatal mice were injected with either this ssAAV9-HexB-P2A-HexA vector (HexB-HexA) or a vehicle solution via the superficial temporal vein. HexB-HexA treatment alone conferred an increase in survival of 56% compared to vehicle-injected controls and biochemical analysis of the brain tissue and serum revealed an increase in HexA activity and a decrease in brain GM2 ganglioside buildup. Additionally, treatments with the non-steroidal anti-inflammatory drug indomethacin (Indo), the histone deactylase inhibitor ITF2357 (ITF) and the pharmacological chaperone pyrimethamine (Pyr) were tested. The anti-inflammatory treatments of Indo and ITF conferred an increase in survival of 12% and 8% respectively while causing no alteration in the HexA activity or GM2 ganglioside buildup. Pyr had no observable effect on disease progression. Lastly HexB-HexA treatment was tested in conjunction with Indo, ITF and Pyr individually. Additive increases in survival and behavioural testing results were observed with Indo and ITF treatments while no additional benefit to HexA activity or GM2 ganglioside levels in the brain tissue was observed. This indicates the two treatments slowed the progression of the disease through a different mechanism than the reduction of the GM2 ganglioside substrate. Pyr treatment was shown to have no effect when combined with HexB-HexA treatment. This study demonstrates the potential amelioration of SD with a novel AAV9 gene therapy approach as well as helped to identify the additive potential of anti-inflammatory treatments in gene therapy of GM2 gangliosidoses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In radiotherapy planning, computed tomography (CT) images are used to quantify the electron density of tissues and provide spatial anatomical information. Treatment planning systems use these data to calculate the expected spatial distribution of absorbed dose in a patient. CT imaging is complicated by the presence of metal implants which cause increased image noise, produce artifacts throughout the image and can exceed the available range of CT number values within the implant, perturbing electron density estimates in the image. Furthermore, current dose calculation algorithms do not accurately model radiation transport at metal-tissue interfaces. Combined, these issues adversely affect the accuracy of dose calculations in the vicinity of metal implants. As the number of patients with orthopedic and dental implants grows, so does the need to deliver safe and effective radiotherapy treatments in the presence of implants. The Medical Physics group at the Cancer Centre of Southeastern Ontario and Queen's University has developed a Cobalt-60 CT system that is relatively insensitive to metal artifacts due to the high energy, nearly monoenergetic Cobalt-60 photon beam. Kilovoltage CT (kVCT) images, including images corrected using a commercial metal artifact reduction tool, were compared to Cobalt-60 CT images throughout the treatment planning process, from initial imaging through to dose calculation. An effective metal artifact reduction algorithm was also implemented for the Cobalt-60 CT system. Electron density maps derived from the same kVCT and Cobalt-60 CT images indicated the impact of image artifacts on estimates of photon attenuation for treatment planning applications. Measurements showed that truncation of CT number data in kVCT images produced significant mischaracterization of the electron density of metals. Dose measurements downstream of metal inserts in a water phantom were compared to dose data calculated using CT images from kVCT and Cobalt-60 systems with and without artifact correction. The superior accuracy of electron density data derived from Cobalt-60 images compared to kVCT images produced calculated dose with far better agreement with measured results. These results indicated that dose calculation errors from metal image artifacts are primarily due to misrepresentation of electron density within metals rather than artifacts surrounding the implants.