3 resultados para Shear stress

em QSpace: Queen's University - Canada


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The walls of blood vessels are lined with a single-cell layer of endothelial cells. As blood flows through the arteries, a frictional force known as shear stress is sensed by mechanosensitive structures on the endothelium. Short and long term changes in shear stress can have a significant influence on the regulation of endothelial function. Acutely, shear stress triggers a pathway that culminates in the release of vasodilatory molecules from the endothelium and subsequent vasodilation of the artery. This endothelial response is known as flow mediated dilation (FMD). FMD is used as an index of endothelial function and is commonly assessed using reactive hyperemia (RH)-FMD, a method which elicits a large, short lived increase in shear stress following the release of a brief (5 min) forearm occlusion. A recent study found that a short term exposure (30 min) to a sustained elevation in shear stress potentiates subsequent RH-FMD. FMD can also result from a more prolonged, sustained increase in shear stress elicited by handgrip exercise (HGEX-FMD). There is evidence to suggest that interventions and conditions impact FMD resulting from sustained and transient shear stress stimuli differently, indicating that HGEX-FMD and RH-FMD provide different information about endothelial function. It is unknown whether HGEX-FMD is improved by short term exposure to shear stress. Understanding how exercise induced FMD is regulated is important because it contributes to blood flow responses during exercise. The study purpose was therefore to assess the impact of a handgrip exercise (intervention) induced sustained elevation in shear stress on subsequent brachial artery (BA) HGEX-FMD. Twenty healthy male participants (22±3yrs) preformed a 30-minute HGEX intervention on two experimental days. BA-FMD was assessed using either an RH or HGEX shear stress stimulus at 3 time points: pre-intervention, 10 min post and 60 min post. FMD and shear stress magnitude were determined via ultrasound. Both HGEX and RH-FMD increased significantly from pre-intervention to 10 min-post (p<0.01). These findings indicate that FMD stimulated by exercise induced increases in shear stress is potentiated by short term shear stress exposure. These findings advance our understanding regarding the regulation of endothelial function by shear stress.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The endothelium is the inner most layer of cells that lines all arteries. A primary function of endothelial cells is to regulate responses to increased blood flow and the resulting frictional forces or shear stress by producing factors such as nitric oxide that mediate arterial dilation (flow mediated dilation (FMD)). Menstrual cycle variations in estrogen (E2) have been shown to influence brachial artery (BA) FMD in response to transient increases in shear stress brought about by the release of a brief forearm occlusion (reactive hyperemia (RH)). FMD can also be assessed in response to a sustained shear stress stimulus such as that created with handgrip exercise (HGEX), and studies have shown that RH- and HGEX stimulated FMD provide unique information regarding endothelial function. However, the impact of menstrual phase on HGEX-FMD is unknown. Therefore, the purpose of this study was to determine the impact of cyclical changes in E2 levels on HGEX-FMD over two discrete phases of the menstrual cycle. FMD was assessed via ultrasound. 12 subjects (21 ± 2yrs) completed two experimental visits: (1) low estrogen phase (early follicular) and (2) High estrogen phase (late follicular). In each visit both RH- and HGEX-FMD (6 min handgrip exercise) were assessed. Results are mean ± SD. E2 increased from the low to the high estrogen phase of the menstrual cycle (low: 34 ± 8, high: 161 ± 113pg/mL, p = 0.004). There was no change in mean FMD between phases (RH-FMD: 7.7 ± 4.3% vs. 6.4 ± 3.1%, p = 0.139; HGEX-FMD: 4.8 ± 2.8% vs. 4.8 ± 2.3%, p = 0.979). The observation that both RH- and HGEX-FMD did not differ between phases indicates that menstrual cycle fluctuations in estrogen may not universally impact endothelial function in young, healthy premenopausal women. Further research is needed to improve our understanding of the mechanisms that underlie variability in the impact of menstrual phase on both transient and sustained FMD responses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Electron beam lithography (EBL) and focused ion beam (FIB) methods were developed in house to fabricate nanocrystalline nickel micro/nanopillars so to compare the effect of fabrication on plastic yielding. EBL was used to fabricate 3 μm and 5 μm thick poly-methyl methacrylate patterned substrates in which nickel pillars were grown by electroplating with height to diameter aspect ratios from 2:1 to 5:1. FIB milling was used to reduce larger grown pillars to sizes similar to EBL grown pillars. X-ray diffraction, electron back-scatter diffraction, scanning electron microscopy, and FIB imaging were used to characterize the nickel pillars. The measured grain size of the pillars was 91±23 nm, with strong <110> and weaker <111> and <110> crystallographic texture in the growth. Load-controlled compression tests were conducted using a MicroMaterials nano-indenter equipped with a 10 μm flat punch at constant rates from 0.0015 to 0.03 mN/s on EBL grown pillars, and 0.0015 and 0.015 mN/s on FIB-milled pillars. The measured Young’s modulus ranged from 55 to 350 GPa for all pillars, agreeing with values in the literature. EBL grown pillars exhibited stochastic strain-bursts at slow loading rates, attributed to local micro yield events, followed by work hardening. Sharp yield points were also observed and attributed to the gold seed layer de-bonding between the nickel pillar and substrate due to the shear stress associated with end effects that arise from the substrate constraint. The onset of yield ranged from 108 to 1800 MPa, which is greater than bulk nickel, but within values given in the literature. FIB-milled pillars demonstrated stochastic yield behaviour at all loading rates tested, yielding between 320 and 625 MPa. Deformation was apparent at FIB-milled pillar tops, where the smallest cross-sectional area was measured, but still exhibited superior yield strength to bulk nickel. The gallium damage at the outer surface of the pillars likely aids in dislocation nucleation and plasticity, leading to lower yield strengths than for the EBL pillars. Thermal drift, substrate effects, and noise due to vibrations within the indenter system contributed to variance and inconsistency in the data.