2 resultados para Repeatability
em QSpace: Queen's University - Canada
Resumo:
Background The Allergic Rhinitis Clinical Investigator Collaborative (AR-CIC) uses a Nasal Allergen Challenge (NAC) model to study the pathophysiology of AR and provides proof of concept for novel therapeutics. The NAC model needs to ensure optimal participant qualification, allergen challenge, clinical symptoms capture and biological samples collection. Repeatability of the protocol is key to ensuring unbiased efficacy analysis of novel therapeutics. The effect of allergen challenge on IL-33 gene expression and its relation to IL1RL1 receptor and cytokine secretion was investigated. Methods Several iterations of the NAC protocol was tested, comparing variations of qualifying criteria based on the Total Nasal Symptom Score (TNSS) and Peak Nasal Inspiratory Flow (PNIF). The lowest allergen concentration was delivered and TNSS and PNIF recorded 15 minutes later. Participants qualified if the particular criteria for the protocol were met, otherwise the next higher allergen concentration (4-fold increase), was administered until the targets were reached. Participants returned for a NAC visit and received varying allergen challenge concentrations depending on the protocol, TNSS/PNIF were recorded at 15 minutes, 30 minutes, 1 hour, and hourly up to 12 hours, a 24 hour time point was added in later iterations. Repeatability was evaluated using a 3-4week interval between screening, NAC1, and NAC2 visits. Various biomarker samples were collected. Results A combined TNSS and PNIF criterion was more successful in qualifying participants. The cumulative allergen challenge (CAC) protocol proved more reliable in producing a robust clinical and biomarker response. Repeatability of the CAC protocol was achieved with a 3-week interval between visits, on a clinical and biological basis. IL-33 cytokine is an important biomarker in initiating the inflammatory response in AR in humans. IL-33 and IL1RL1 expression might employ a negative feedback mechanism in human nasal epithelial cells. Comparing the clinical and biological response to ragweed vs cat allergen challenge, proved the CAC protocol’s suitability for use employing different allergens. Conclusion The AR-CIC’s CAC protocol is an effective method of studying AR, capable of generating measurable and repeatable clinical and biomarker responses, enabling better understanding of AR pathophysiology and ensuring that any change would be purely due to medication under investigation in a clinical trial setting.
Resumo:
Measurement of joint kinematics can provide knowledge to help improve joint prosthesis design, as well as identify joint motion patterns that may lead to joint degeneration or injury. More investigation into how the hip translates in live human subjects during high amplitude motions is needed. This work presents a design of a non-invasive method using the registration between images from conventional Magnetic Resonance Imaging (MRI) and open MRI to calculate three dimensional hip joint kinematics. The method was tested on a single healthy subject in three different poses. MRI protocols for the conventional gantry, high-resolution MRI and the open gantry, lowresolution MRI were developed. The scan time for the low-resolution protocol was just under 6 minutes. High-resolution meshes and low resolution contours were derived from segmentation of the high-resolution and low-resolution images, respectively. Low-resolution contours described the poses as scanned, whereas the meshes described the bones’ geometries. The meshes and contours were registered to each other, and joint kinematics were calculated. The segmentation and registration were performed for both cortical and sub-cortical bone surfaces. A repeatability study was performed by comparing the kinematic results derived from three users’ segmentations of the sub-cortical bone surfaces from a low-resolution scan. The root mean squared error of all registrations was below 1.92mm. The maximum range between segmenters in translation magnitude was 0.95mm, and the maximum deviation from the average of all orientations was 1.27◦. This work demonstrated that this method for non-invasive measurement of hip kinematics is promising for measuring high-range-of-motion hip motions in vivo.