3 resultados para Network air gap
em QSpace: Queen's University - Canada
Resumo:
Multi-frequency Eddy Current (EC) inspection with a transmit-receive probe (two horizontally offset coils) is used to monitor the Pressure Tube (PT) to Calandria Tube (CT) gap of CANDU® fuel channels. Accurate gap measurements are crucial to ensure fitness of service; however, variations in probe liftoff, PT electrical resistivity, and PT wall thickness can generate systematic measurement errors. Validated mathematical models of the EC probe are very useful for data interpretation, and may improve the gap measurement under inspection conditions where these parameters vary. As a first step, exact solutions for the electromagnetic response of a transmit-receive coil pair situated above two parallel plates separated by an air gap were developed. This model was validated against experimental data with flat-plate samples. Finite element method models revealed that this geometrical approximation could not accurately match experimental data with real tubes, so analytical solutions for the probe in a double-walled pipe (the CANDU® fuel channel geometry) were generated using the Second-Order Vector Potential (SOVP) formalism. All electromagnetic coupling coefficients arising from the probe, and the layered conductors were determined and substituted into Kirchhoff’s circuit equations for the calculation of the pickup coil signal. The flat-plate model was used as a basis for an Inverse Algorithm (IA) to simultaneously extract the relevant experimental parameters from EC data. The IA was validated over a large range of second layer plate resistivities (1.7 to 174 µΩ∙cm), plate wall thickness (~1 to 4.9 mm), probe liftoff (~2 mm to 8 mm), and plate-to plate gap (~0 mm to 13 mm). The IA achieved a relative error of less than 6% for the extracted FP resistivity and an accuracy of ±0.1 mm for the LO measurement. The IA was able to achieve a plate gap measurement with an accuracy of less than ±0.7 mm error over a ~2.4 mm to 7.5 mm probe liftoff and ±0.3 mm at nominal liftoff (2.42±0.05 mm), providing confidence in the general validity of the algorithm. This demonstrates the potential of using an analytical model to extract variable parameters that may affect the gap measurement accuracy.
Resumo:
Wireless sensor networks (WSNs) have shown wide applicability to many fields including monitoring of environmental, civil, and industrial settings. WSNs however are resource constrained by many competing factors that span their hardware, software, and networking. One of the central resource constrains is the charge consumption of WSN nodes. With finite energy supplies, low charge consumption is needed to ensure long lifetimes and success of WSNs. This thesis details the design of a power system to support long-term operation of WSNs. The power system’s development occurs in parallel with a custom WSN from the Queen’s MEMS Lab (QML-WSN), with the goal of supporting a 1+ year lifetime without sacrificing functionality. The final power system design utilizes a TPS62740 DC-DC converter with AA alkaline batteries to efficiently supply the nodes while providing battery monitoring functionality and an expansion slot for future development. Testing tools for measuring current draw and charge consumption were created along with analysis and processing software. Through their use charge consumption of the power system was drastically lowered and issues in QML-WSN were identified and resolved including the proper shutdown of accelerometers, and incorrect microcontroller unit (MCU) power pin connection. Controlled current profiling revealed unexpected behaviour of nodes and detailed current-voltage relationships. These relationships were utilized with a lifetime projection model to estimate a lifetime between 521-551 days, depending on the mode of operation. The power system and QML-WSN were tested over a long term trial lasting 272+ days in an industrial testbed to monitor an air compressor pump. Environmental factors were found to influence the behaviour of nodes leading to increased charge consumption, while a node in an office setting was still operating at the conclusion of the trail. This agrees with the lifetime projection and gives a strong indication that a 1+ year lifetime is achievable. Additionally, a light-weight charge consumption model was developed which allows charge consumption information of nodes in a distributed WSN to be monitored. This model was tested in a laboratory setting demonstrating +95% accuracy for high packet reception rate WSNs across varying data rates, battery supply capacities, and runtimes up to full battery depletion.
Resumo:
The Canadian economy is largely dependent on the distribution of large volumes of oil to domestic and international markets by a long network of pipelines. Unfortunately, accidents occur, and oil can leak or spill from these pipelines before it reaches its destination. Of particular concern are the long-term consequences of oil spills in freshwater, which include sinking of oil in water and the contamination of sensitive areas, such as where fish (e.g., salmon) deposit their eggs in gravel-dominated river sediments. There is a knowledge gap regarding the fate and behaviour of oil in river sediment. To this end, this study aimed at finding the potential for diluted bitumen (dilbit) oil to become trapped in gravel and to transfer hydrocarbons into water by dissolution, which are harmful to aquatic life. Two sets of laboratory experiments were conducted to simulate conditions of an oil spill on an exposed bank or in shallow water. In the first set, by conducting capillary pressure-saturation (Pc-Sw) experiments it was found that dilbit can enter gravel pores without much resistance and approximately 14% of the pore volume can be occupied by discontinuous single or multipore blobs of dilbit following imbibition of water. Air-water Pc-Sw experiments done in laboratory 1-D columns required gravity correction and could be successfully scaled to predict dilbit-water Pc-Sw curves, except for the trapped amount of dilbit. Trapped dilbit constituents can be dissolved into the water flowing through gravel pores (hyporheic flow) at different velocities. In the second set, dissolution experiments suggested that for the duration of the test, hydrocarbons that cause acute toxicity dissolve rapidly, likely resulting in a decrease in their effective solubility. However, dilbit saturation changed only <2% within that time. Chronically toxic PAH compounds were also detected in the effluent water. The total concentration of all detected PAHs and alkylPAHs exceeded the threshold literature value to protect early-life stage fish. Observations of decreased concentrations with increased aqueous velocities as well as less than equilibrium concentrations indicated that the mass transfer was rate-limited. A correlation was developed for the mass transfer rate coefficient to understand the mass transfer behaviour beyond the conditions used in the experiments, which had a Reynolds number exponent similar to the studies of NAPL dissolution in groundwater.