3 resultados para Formative assessment framework. Assessment tools. Ames
em QSpace: Queen's University - Canada
Resumo:
Formative assessment was introduced in Rehabilitation Therapy students’ information literacy programs in Fall Term 2006 in the course OT/PT 892: Evidence-Based Practice. It was subsequently employed in the Winter Term 2008 and again in the Spring Term 2008. Formative assessment during student/librarian face-to-face consultations was one of a variety of teaching techniques used in the program. Other techniques included: a required reading; an interactive hands-on searching session; and a summative assessment of the final revised search strategy assignment (these techniques varied somewhat over the 3 classes). With the 2008 entrance class, this course content moved to OT/PT 898: Critical Enquiry, largely in Module 3: Reviewing the Literature. One of the Critical Enquiry’s learning objectives is: “recognize and reflect on the complexity of gathering evidence to inform decision-making.”
Resumo:
Stroke is a prevalent disorder with immense socioeconomic impact. A variety of chronic neurological deficits result from stroke. In particular, sensorimotor deficits are a significant barrier to achieving post-stroke independence. Unfortunately, the majority of pre-clinical studies that show improved outcomes in animal stroke models have failed in clinical trials. Pre-clinical studies using non-human primate (NHP) stroke models prior to initiating human trials are a potential step to improving translation from animal studies to clinical trials. Robotic assessment tools represent a quantitative, reliable, and reproducible means to assess reaching behaviour following stroke in both humans and NHPs. We investigated the use of robotic technology to assess sensorimotor impairments in NHPs following middle cerebral artery occlusion (MCAO). Two cynomolgus macaques underwent transient MCAO for 90 minutes. Approximately 1.5 years following the procedure these NHPs and two non-stroke control monkeys were trained in a reaching task with both arms in the KINARM exoskeleton. This robot permits elbow and shoulder movements in the horizontal plane. The task required NHPs to make reaching movements from a centrally positioned start target to 1 of 8 peripheral targets uniformly distributed around the first target. We analyzed four movement parameters: reaction time, movement time (MT), initial direction error (IDE), and number of speed maxima to characterize sensorimotor deficiencies. We hypothesized reduced performance in these attributes during a neurobehavioural task with the paretic limb of NHPs following MCAO compared to controls. Reaching movements in the non-affected limbs of control and experimental NHPs showed bell-shaped velocity profiles. In contrast, the reaching movements with the affected limbs were highly variable. We found distinctive patterns in MT, IDE, and number of speed peaks between control and experimental monkeys and between limbs of NHPs with MCAO. NHPs with MCAO demonstrated more speed peaks, longer MTs, and greater IDE in their paretic limb compared to controls. These initial results qualitatively match human stroke subjects’ performance, suggesting that robotic neurobehavioural assessment in NHPs with stroke is feasible and could have translational relevance in subsequent human studies. Further studies will be necessary to replicate and expand on these preliminary findings.
Resumo:
Objectives: The main objective of this pilot study was to investigate which standardized functional and physiological test best predicted perceived disability in a single group of 21 individuals diagnosed with osteoarthritis of the hip. Design: Men and women between 60 and 70 years old with osteoarthritis of the hip were selected. If participants passed study criteria, the Western Ontario McMaster University questionnaire (WOMAC), 6 Minute Walk Test (6MWT) and Timed up and Go (TUG), strength testing and aerobic testing were obtained in one single assessment. Results: Regression analysis revealed that wait time, hip abduction strength of the affected side, Aerobic Capacity (VO2 Peak), hip Extension Peak Torque, hip Flexion Peak Torque, TUG and 6MWT were significantly correlated with the WOMAC. Yet, the 6MWT had the highest significant correlation (r = -0.86, p ≤ 0.0001); R2 = 0.75 or 75% with the WOMAC total scores, (r = -0.82, p ≤ 0.0001); R2 = 0.67 or 67% with the WOMAC function and (r = -0.60, p = .002); R2 = 0.36 or 36% with the WOMAC stiffness. While the VO2 Peak revealed the highest significant correlation (r = 0.76, p ≤ .0001); R2 = 0.57 or 57% with the WOMAC pain. Conclusions: The 6MWT and the VO2 Peak seem to be essential functional and physiological assessment tools to determine perceived disability in individuals with hip OA. The perceived disability may provide new or comprehensive knowledge of the disability problems experienced by individuals with osteoarthritis of the hip, and the association of patient perception with objective measures of functional and physiological capacity might strengthen the clinical value of this knowledge.