2 resultados para Fabrication of cDNA Micoarrays

em QSpace: Queen's University - Canada


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work I study the optical properties of helical particles and chiral sculptured thin films, using computational modeling (discrete dipole approximation, Berreman calculus), and experimental techniques (glancing angle deposition, ellipsometry, scatterometry, and non-linear optical measurements). The first part of this work focuses on linear optics, namely light scattering from helical microparticles. I study the influence of structural parameters and orientation on the optical properties of particles: circular dichroism (CD) and optical rotation (OR), and show that as a consequence of random orientation, CD and OR can have the opposite sign, compared to that of the oriented particle, potentially resulting in ambiguity of measurement interpretation. Additionally, particles in random orientation scatter light with circular and elliptical polarization states, which implies that in order to study multiple scattering from randomly oriented chiral particles, the polarization state of light cannot be disregarded. To perform experiments and attempt to produce particles, a newly constructed multi stage thin film coating chamber is calibrated. It enables the simultaneous fabrication of multiple sculptured thin film coatings, each with different structure. With it I successfully produce helical thin film coatings with Ti and TiO_{2}. The second part of this work focuses on non-linear optics, with special emphasis on second-harmonic generation. The scientific literature shows extensive experimental and theoretical work on second harmonic generation from chiral thin films. Such films are expected to always show this non-linear effect, due to their lack of inversion symmetry. However no experimental studies report non-linear response of chiral sculptured thin films. In this work I grow films suitable for a second harmonic generation experiment, and report the first measurements of non-linear response.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research presents a new design of an adjustable suture that could provide a better intraocular pressure (IOP) control in the post treatment of trabeculectomy surgery and limit associated complication with the current suturing techniques. A better control in tension suture brings a great deal of advantages to this surgical technique compared with the traditional adjustable suture. A length adjustment can be added in advance to a 10-0 nylon suture which enables suture tension to be released during the postoperative period of trabeculectomy surgery. This adjustment has a D-ring geometry made of 10-0 nylon suture adhered to a 10-0 nylon surgical suture which is used to close the scalar flap. The D ring was adhered with about 180 microdroplet of Loctite 4311that was found to form a strong joint to connect the D ring to the main 10-0 nylon suture and strong enough to carry the added tension instead after cutting the central suture between the two joints of the D ring. The geometry of adjustment is the key factor of maintaining the IOP at the normal range and keeping the scleral flap tight enough and secure so that aqueous humor continues to percolate under the subconjunctiva. It has been found that a 365, and 450 µm length extensions can release suture tension postoperatively and relieve the intraocular pressure within the eye by 33, and 66% respectively. The fabrication process of the new adjustable suture was divided into two steps: fabrication of micro jig and forming microdroplets. A micro jig was fabricated in order to form and bond a precise length extension to the new design of the adjustable suture. In addition, a new liquid separation technique has been followed in this study in order to generate micro adhesive droplets as small as 50µm for bonding the new adjustable suture structure.